Showing results: 9766 - 9780 of 11094 items found.
-
621 -
The Eastern Specialty Company
TESCO’s light-weight, 50 Amp Field Meter Test Kit (Catalog No. 621) with Power Factor, has been designed to reduce the weight of field test equipment to the lowest possible limit. The carrying case is fabricated from durable powder coated aluminum. The total weight of the meter test kit including leads, and digital reference standard is only 25 lbs! The test kit also incorporates ample storage space for the cable set.
-
Y1800A -
Keysight Technologies
The RF transceiver kit consists of a transmitter unit and a receiver unit in superheterodyne architecture. The transceiver units are made up of various RF building-block modules such as filter, low noise amplifier, power amplifier, mixer and oscillator. The RF transceiver kit is controlled by a Windows-based Control Panel software via USB. A Measurement Automation Program is provided to demonstrate automated characterization and test of RF circuits. A signal generator and a spectrum analyzer are required to run this program.
-
288 SVD -
Standard Electric Works Co., Ltd
● AC Voltage detection: 240V ~ 50kV ● Waterproof● Easy-to-wear on body or belt ● Ultra-bright LED indication● High pitch sound indication● Self-test & diagnostic circuitry● Friendly priority alert reporting● High impact type casing● Different alerting sound & light● Meets EN 61326-1● Dimension : 114(L) × 67(W) × 27(D) mm● Weight : Approx. 152g (battery included)● Power supply : 9V(6F22) × 1
-
350 SVD -
Standard Electric Works Co., Ltd
● Protection class: IP65● Bright LED visual indication● Audible indication● Non-contact voltage detection: 220Vac ~ 132kVac● Wide angle voltage detection● Frequency range: 40 ~ 70Hz ● Easy-to-prove method● Self-test function● Power source: 9V rechargeable battery ● Non-contact detection by proximity● Flashlight function● Operating temperature: 0°C~50°C● Humidity: 80% RH Max● Lightweight, robust and compact● Comply with EN 61326-1
-
8012 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Extra large LCD(78 × 67mm).● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Auto power off.● Auto off and off override.● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.●Frequency measurement indication.
-
302 SVD -
Standard Electric Works Co., Ltd
● Bright LED visual indication● Audible indication● Mute function● AC voltage detection: 100Vac ~ 50kVac● Frequency range: 50/60Hz● Easy-to-prove method● Self-test function● Power source: 1.5V(AA) alkaline battery × 3● Non-contact detection by proximity● Convenient to use● Operating temperature and humidity: 0°C~40°C / 80% RH Max.● Lightweight, robust and compact● Easy access to batteries● Comply with EN 61326-1
-
2660 CL -
Standard Electric Works Co., Ltd
● 4000 counts.● Voltage measurement, current measurement, resistor measurement, frequency counter, capacitor measurement.● Bargraph indication.● Range change function.● Data hold function freezes the reading.● REL function.● Peak function.● Diode measurement.● Max / Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
-
4235 ER -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Earth resistivity (ρ) test.● Earth testing at 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test, 3-Wire test, 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● 200 measurement results can be saved in the memory and recalled on the display.● Interval between auxiliary earth spikes is 1.0~50.0m.
-
DEL-101 -
Standard Electric Works Co., Ltd
● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.
-
779892-03 -
NI
The NI‑9871 adds RS485/RS422 serial ports to CompactRIO systems. The serial ports are accessed directly from the FPGA to offer you flexibility in communicating with serial devices. The module has individual buffers on every port that save FPGA space and simplify programming. The NI‑9871 supports standard start bit, stop bit, and handshaking settings. It uses an external power to provide maximum compatibility and reliability under all serial port conditions.
-
779892-02 -
NI
The NI‑9871 adds RS485/RS422 serial ports to CompactRIO systems. The serial ports are accessed directly from the FPGA to offer you flexibility in communicating with serial devices. The module has individual buffers on every port that save FPGA space and simplify programming. The NI‑9871 supports standard start bit, stop bit, and handshaking settings. It uses an external power to provide maximum compatibility and reliability under all serial port conditions.
-
779891-02 -
NI
The NI‑9870 adds RS232 serial ports to CompactRIO systems. The serial ports are accessed directly from the FPGA to offer you flexibility in communicating with serial devices. The module has individual buffers on every port that save FPGA space and simplify programming. The NI‑9870 supports standard start bit, stop bit, and handshaking settings. It uses an external power to provide maximum compatibility and reliability under all serial port conditions.
-
779891-03 -
NI
The NI‑9870 adds RS232 serial ports to CompactRIO systems. The serial ports are accessed directly from the FPGA to offer you flexibility in communicating with serial devices. The module has individual buffers on every port that save FPGA space and simplify programming. The NI‑9870 supports standard start bit, stop bit, and handshaking settings. It uses an external power to provide maximum compatibility and reliability under all serial port conditions.
-
ROM-3310 Development Kit -
Advantech Co. Ltd.
*Evaluation kit for ROM-3310*Lower power TI sitara AM3352 1GHz processor*On board DDR3 512MB memory / 4GB Flash*HW WDT for system protection*Supports 1 GbE, 1 USB 2.0, 1 USB 2.0 OTG, 2 CANbus, 10 GPIO, 4 UART,1 I2C, 1 I2S, 1 SPI, 1 SDIO*Cable pack & Panel included*Evaluative image & test utilities built-in
-
Model 253 -
Telebyte, Inc.
FEATURES: DB9 Data Port; Compatible with PC/386/486; Full Duplex; Surge Protection. Adding an RS-422 interface to a PC is now a snap. The Model 253 Interface Converter does this for full duplex signals at data rates up to 19.2 KBPS, without requiring any AC or DC power. With only TD, RD and ground, the Model 253 provides operation over 8,000 feet of twisted pair into a load of 120 Ohms.