Showing results: 7096 - 7110 of 11103 items found.
-
-
-
-
-
EMAX -
PdMA Corporation
The EMAX tester allows for proactive predictive maintenance without requiring a shutdown of the motors for access. The power and convenience of dynamic testing collects data without interrupting production processes. The EMAX can be used for process analysis with motor current signature analysis and also provides voltage, power, and efficiency data.
-
Phillips Aerospace
Deliverables• Flight Cables and Line Replaceable Units• Weapons Replaceable Assemblies• Stationary and Portable Special Test Equipment• EMI, Thermal Vac Test Cables• Hardware in the Loop Testers• Automated Fault Insertion Systems• Data Acquisition• Power Quality and Power Monitoring• RF Test and Communications
-
Mors Smitt Group
The transducers are based on compensating the magnetic field by a closed loop system. Ensure high accuracy of voltage and current measuring in railway traction or substation power equipment for protetion against power surges, overload, ground fault detection. Hall effect measurement to offer maximum protection in railway applications.
-
Mercury Systems, Inc.
High-power, rackmount amplifiers utilize advanced power combining techniques to achieve high output power levels. These integrated amplifiers include advanced cooling capabilities and other customizable features. Though a focus on modularity, these rackmount amplifiers are ready for easy integration into a larger system or lab test bench.
-
Schwarzbeck Mess Elektronik
Tuned half-wave dipoles have been among the most important antennas from thebeginning of rf-technique. The characteristics of half-wave dipoles havebeen calculable very early using the Maxwell and Hertz equations. Therefore the halfwave dipole became a reference antenna. The ideal (lossless) half-wave dipole has anisotropic gain of 2.15 dBi and an impedance of 73 Ohm. The directional pattern is circular inthe H-plane, "8-shaped" in the E-plane with the maxima perpendicular on the dipole axis.The half-power beamwidth (-3 dB) is approx. 78°. The impedance of real dipoles isdepending on the thickness/length ratio of its elements, typical values are 60-70 Ohm.Dipoles for industrial applications are available in the frequency range from 30MHz to up to approx. 4 GHz. The dipole elements are length variable (telescopic) orwith fixed length, the latter especially above 1 GHz. The most important applications aretest site evaluations (NSA, normalized site attenuation) and the determination of ERP(Effective Radiated Power) respectively EIRP (Effective Isotropic Radiated Power).
-
RF ONE 3029 -
LBA Group, Inc
The RF One Power Meter is a very versatile instrument covering both analog and digital carriers in an extremely wide frequency range from 30MHz to 6GHz. The RF One is capable of measuring forward and reflected power in the range of a few milliwatts up to 500 Watts. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The RF One instrument is small, handy and light weight battery operated with more than 3 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.
-
ET Power Systems Ltd.
The standard range of DC-DC Converters contains units with power outputs from 40W to 5kW. Small footprints, high conversion efficiencies and floating outputs are common throughout the converter range. For users that require the highest reliability a number of our converter families demonstrate MTBF figures of 750,000 hours. Our most rugged converter designs are capable of operating in ambient temperatures as low as -40°C and as high +80°C.
-
Advanced Science and Novel Technology, Co., Inc.
High-speed broadband Data/Clock Amplifier and DistributorExhibits low jitter and limited temperature variation over industrial temperature rangeOne input differential signal port and two differential amplified output signal portsMatched phase delays for all outputsFully differential CML input interfaceFully differential CML output interfaces with 600mV single-ended swingSingle +3.3V or -3.3V power supplyPower consumption: 560mWFabricated in SiGe for high performance, yield, and reliability
-
BAS003 -
Larson Davis, Inc.
The BAS003 Source is designed to generate homogeneous sound fields using random noise in compliance with the following standards: Building acoustics (insertion loss, acoustic absorption area, etc: ISO 140-3, ASTM E90, ISO 140-5, ASTM E966). The BAS003 is typically used to generate a noise in a free-field for the evaluation of the transmission loss index of a façade. The available high-efficiency power amplifier, BAS002, is light and can be remotely controlled for easy use in the field.
-
LatticeECP3 -
Lattice Semiconductor
*Up to 16 channels at 3.125 Gbps*800 MBps DDR3, 1Gbps LVDS*Up to 586 programmable sysIO buffers with support for PCI Express, Ethernet (GbE, XAUI, & SGMII), HDMI, SMPTE, Serial Rapid I/O, CPRI and JESD204A/B and more*Up to 150 k LUTs and 6.8 Mbits of SRAM*Wide array of packages as small as 10.0 mm x 10.0 mm with power consumption below 0.5 W
-
HD22.2 - HD22.3 -
Delta OHM S.r.L.
HD22.2: Laboratory electrode holder composed of base plate with built-in magnetic stirrer, shaft and replaceable electrode hold-er. Suitable diameter 12 mm. It holds up to 5 electrodes at the same time. Powered by power supplier SWD10 (optional). HD22.3: Laboratory electrode holder composed of base plate. Flexible arm for free positioning. Suitable for electrodes with diameter 12 mm. It holds up to 5 electrodes at the same time.