Filter Results By:

Products

Applications

Manufacturers

Showing results: 166 - 170 of 170 items found.

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Coating Thickness Gauge for Ferrous and Non-Ferrous Materials

    CM8856 - Rinch Industrial Co.,Limited

    * It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTM and BS. It can be used both in the laboratory and in harsh field conditions.* The F probes measure the thickness of non-magnetic materials (e.g. paint,plastic, porcelain enamel, copper, zinc,aluminum , chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness ofgalvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminum tile, somealloy tile, paper etc.The N probes measure the thickness of non - magnetic coatings on non-magnetic metals .It is used on anodizing, varnish, paint, enamel,plastic coatings, powder, etc. appliedto aluminum, brass, non-magnetic stainless steel, etc.* Automatic substrate recognition.* Manual or automatic shut down.* Two measurement mode: Single andContinuous* Wide measuring range and highresolution.* Metric/Imperial conversion.* Digital backlit display gives exactreading with no guessing or errors.* Can communicate with PC computerfor statistics and printing by theoptional cable.* Can store 99 groups of measurements.* Statistics is available.2.SPECIFICATIONSDisplay: 4 digits LCD, backlitRange: 0~1250 μm/0~50mil(other ranges can be specified )Min.radius workpiece: F: Convex 1.5mm/Concave 25mmN: Convex 3mm/ Concave 50mmMin. measuring area: 6mmMin.Sample thickness : 0.3mmResolution: 0.1 μm (0~99.9μm);1 μm (over 100μm)Accuracy: ±1~3%n or 2.5 μm or 0.1mil(Whichever is the greater)Bttery Indicator: Low batter indicator.PC interface: with RS-232C interfacePower supply: 2x1.5 AAA(UM-4) batteryOperating condition: Temp. 0~50℃ .Humidity <95% .Size: 126x65x35 mm; 5.0x2.6x1.6 inchWeight: about 81g(not including batteries)Standard accessories:Carrying case ...................1 pc.Operation manual ............ 1 pc.F probe in built .................1 pc.NF probe in built...............1 pc.Calibration foils ..............1set.Substrate (Iron) ................1 pc.Substrate (Aluminium)......1 pc.Optional accessories: RS-232C cable & software:1.USB adaptor for RS-232C2.Bluetooth interface

  • Coating Thickness Gauge

    CM8855 - Rinch Industrial Co.,Limited

    It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTMand BS. It can be used both in the laboratory and in harsh field conditions. The F probes measure the thickness of non-magnetic materials (e.g. paint,plastic, porcelain enamel, copper, zinc, aluminum , chrome etc.) on magneticmaterials (e.g. iron, nickel etc.) . often used to measure the thickness ofgalvanizing layer, lacquer layer,porcelain enamel layer, phosphidelayer, copper tile, aluminum tile, some alloy tile, paper etc. The N probes measure the thickness of non - magnetic coatings on non-magnetic metals .It is used on anodizing, varnish, paint, enamel,plastic coatings, powder, etc. appliedto aluminum, brass, non-magnetic stainless steel, etc. Automatic substrate recognition. Manual or automatic shut down. Two measurement mode: Single and Continuous Wide measuring range and high resolution. Metric/Imperial conversion. Digital backlit display gives exact reading with no guessing or errors. Can communicate with PC computer for statistics and printing by the optional cable. Can store 99 groups of measurements. Statistics is available.2.SPECIFICATIONSDisplay: 4 digits LCD, backlitRange: 0~1250 μm/0~50mil (other ranges can be specified )Min.radius workpiece: F: Convex 1.5mm/Concave 25mmN: Convex 3mm/ Concave 50mmMin. measuring area: 6mmMin.Sample thickness : 0.3mmResolution: 0.1 μm (0~99.9μm);1 μm (over 100μm)Accuracy: ±1~3%n or 2.5 μm or 0.1mil(Whichever is the greater)Bttery Indicator: Low batter indicator.PC interface: with RS-232C interfacePower supply: 2x1.5 AAA(UM-4) batteryOperating condition: Temp. 0~50℃ .Humidity <95% .Size: 126x65x35 mm; 5.0x2.6x1.6 inchWeight: about 81g(not including batteries)Standard accessories:Carrying case ...................1 pc.Operation manual ............ 1 pc.F probe in built .................1 pc.NF probe in built...............1 pc.Calibration foils ..............1set.Substrate (Iron) ................1 pc.Substrate (Aluminium)......1 pc.Optional accessories: RS-232C cable & software:1.USB adaptor for RS-232C2.Bluetooth interface

Get Help