Filter Results By:

Products

Applications

Manufacturers

Model

construction of a concept.

See Also: Modeling, Modelling, Modelers, Human Body Model, Charged Device Model


Showing results: 4051 - 4065 of 4104 items found.

  • Clamp Meters

    PCE Instruments

    The clamp meter is ideal for measuring AC or DC voltage. The instrument is irreplaceable for inspection work and maintenance in various industrial applications, in research and development, in residential applications and in many small businesses or households. The PCE line of clamp meter is made according to the highest industry standards and very important: PCE offers instruments that are usable in all workspaces (equipped with very small or even very large jaws), the results are reliable and the clamps are easy to use. Every clamp meter is manufacturer calibrated and can be certified to ISO or NIST - hold a PCE clamp meter in your hands and you can feel the quality immediately.PCE offers a variety of models: Voltage detector, voltage leak detector, voltage power detector, metric detector and current detector. In addition many clamp meters are able to measure other parameters, such as capacity, resistance and power - power through clamps directly or by handheld digital instruments with external clamps (with a range of one or three stages). Very often the clamp meter is a real multimeter - so it becomes a general electrical measurement tool.

  • Ion 700 Benchtop Meters

    OAKTON Instruments

    Oakton benchtop 700-series meters are designed for use in crowded laboratory settings. Compact footprint of less that 6" x 7" (16 x 18 cm) conserves valuable space, while the large, dual-display LCD provides excellent visibility—even from a distance. Ion 700 meter measures pH, mV, relative mV, ion concentration and temperature. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Models feature five-point pH calibration with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers. Meters additionally feature ion concentration calibration of up to 5 points. Meter features include Auto-Hold, selectable °F or °C measurement, and easy recall of electrode slope or offset. The convenient pull-out quick reference card keeps procedures handy at all times. Use 700-series meters with any pH, ORP, or ISE electrodes with a BNC connector.

  • CO Monitor

    AI-1200 - Airspace Monitoring Systems

    AGS with Snif technology, and now with a backlit LCD display, the 1200 monitor will accurately measure and display CO levels from 12 ppm to 250 ppm. It also includes alarms like the 1100 with a panel of flashing lights and 92 decibel audio that begins at 30 ppm and grows in intensity to 120 ppm. The Snif technology provides an update every 4 seconds when in alarm to help you find the source, see the trend and otherwise manage the CO event. Like all of our V2 models, it now has a motion switch option built into it. When motion switch management is chosen, the monitor will turn itself on by any movement and if it doesn't sense CO or hasn't moved in 45 minutes, it will shut itself off. The motion switch allows passive screening capability that can dramatically stretch your battery life without risk of forgetting to turn the monitor on or off. Like all of our monitors, there is no routine bump testing or calibration required and the monitor is warranted for five years, even the sensor and its calibration is included in the warranty.

  • Temperature Data Acquisition

    THERMES-USB - Physitemp Instruments

    Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)

  • Reach-In Altitude Test Chamber

    ACMAS Technologies Pvt. Ltd.

    Weiber Altitude Test Chamber combine temperature and altitude to test basic components or subassemblies designed for use in a variety of industries. With altitude test chambers, user can control the temperature environment for testing while simulating various altitudes from site level to 10,400 meters (25kPa). Altitude testing may be continued without temperature control up to 600,000 meters (0.1 kPa).High Low Temperature Altitude Test Chamber is used to test temperature and low-pressure altitude conditions simultaneously. Two common applications of High Low Humidity Altitude Test Chamber are testing of avionics or other aerospace equipment to simulate actual conditions, and simulate high-altitude conditions found in mountainous regions or other regions. All models are factory tested, with an ergonomic and maintenance cum user-friendly design. These CE approved test chambers are created with multi-layered insulation with double vapour barrier is of low 'K' factor, high density and of non-hygroscopic in nature. Weiber test chamber are made in accordance with the international standard. Weiber Test Chambers are GMP complaints and are also ISO and NABL certified.

  • Ultrasonic Flaw Detector

    MFD550B - Mitech Co., LTD.

    Based on ultrasonic principle, digital ultrasonic flaw detector MFD550B can test, orient, evaluate and diagnose various flaws such as crack, lard, air hole in workpiece’s interior swiftly and accurately without any destruction. With full digital 640X480 TFT LCD display, it show the defect clearly under the dim light and strong sunlight environment. 0-9999mm measuring range can meet the requirement for general defect inspection in manufacturing industry, metallurgical industry, metal processing industry, chemical industry and so on. Low power design with large capacity and high performance lithium ion battery module,it can work more than 10 hours continuously. Full English master-slave menu, emphasizing on user experience, collecting shortcut keys, digital shuttle rotary wheel, cross menu three operating ways inone body, customers with different habits can operate it freely. With comprehensive performance self-checking function, it can automatically generate test reports and support for many languages. With high cost performance, it is the smart choice for the practical economic model of ultrasonic testingequipment.

  • ±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester

    HBM-S1-B - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm

  • External Measurement Instrument Port | Add-On Option to CableEye HVX Series Testers

    Item 835 - CAMI Research Inc. (CableEye®)

    Measure 10 GΩ Isolation at 100 V

    This new capability is of special interest to customers requiring measurements of extremely high isolation resistance at very low voltages. The HVX-series option may be ordered with new testers or added as an upgrade to previously purchased systems. Application Applications for such high isolation measurements at very low voltage include mission critical devices with densely packed pins that would arc at higher voltages potentially causing damage: For example, the testing of military or aerospace cables with nano connectors. Exacting Reporting Standards CableEye® software allows customers to meet the most exacting reporting requirements of government-contracted and ISO 9000-style certified companies. Co-Requisites This options co-requires the 4-Wire Kelvin Resistance Measurement option (Item 832), and a third party source Source Measure Unit (SMU – Keithley Model 2410 or 2470).

  • Mobile Comm DC Source w/ Battery Emulation, DVM

    66321D - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.The Keysight 66321D mobile communications dc source provides fast transient response, exceptional sourcing, output resistance programming, and precision measurement. This product is specially designed for testing next generation digital wireless communications products. The 66321D mobile communications dc source offers a new capability that simulates the internal resistance of a battery or battery pack. Additionally, these high performance models offer improved transient response and stable output operation with either short or long load leads. The 66321D dc source provides all of the capabilities of the 66321B with the addition of a built-in digital voltmeter.

  • Instrument Systems LED Measurement Accessories

    Konica Minolta Sensing Americas, Inc

    It’s critical to use the appropriate LED measurement equipment and accessories when evaluating an LED’s various photometric and radiometric quantities. Because all of the test adapters Instrument Systems designs are compliant with CIE 127:2007, users are assured of compatibility between measurements. Instrument Systems has a diverse array of LED Measurement Equipment. Whether you are looking to measure average LED intensity or high power LEDs, Instrument Systems has LED test sockets that can meet your requirements. Additionally, the LED-81X/-850 model, normally used for high power LED measurement, is also passively cooled using a thermal fan and sink to ensure the longevity of the Instrument Systems LED measurement equipment and can even be set to have a temperature range of +5 to +85 degrees Celsius to control heating and cooling. Instrument Systems also makes integrating their LED measurement equipment relatively simple requiring minimal calibrations. It is recommended that to completely automate your measuring applications you consider using a software add on that was developed by Instrument Systems for SpecWin Pro.

  • Radius Radiation Probe

    Hawk Radius® - International Medcom

    The Hawk® Radius is a ruggedized solution for monitoring both ambient and elevated levels of ionizing radiation. Like a Hawk with its remarkable vision, the Hawk Radius Probe “sees” things that other probes cannot. The high sensitivity weatherized pancake sensor can provide early warning of changing ambient radiation conditions, while the energy compensated detector can accurately report penetrating gamma radiation dose rate at elevated levels. Radius probes are typically deployed as part of an environmental radiation monitoring program, or for safety and security systems. In its standard configuration the probe detects beta, low energy gamma and x-radiation with one channel and energy compensated penetrating gamma radiation levels with a second channel. It can be configured to detect alpha radiation as well. The Hawk® Radius has been deployed worldwide in demanding conditions for protecting communities and collecting environmental radiation data. It can be deployed easily and requires minimum maintenance. The Radius is compatible with Medcomʻs GeigerLink adapter and the IMI Gateway App for use with personal computers. It can also be used with most data loggers including popular Campbell Scientific models.

  • High Voltage Surge Current Monitors

    HVSCM - Test Electronics

    Designed to be used with the Model HVST High Voltage Surge tester. The Surge Current Monitor allows simultaneously surge testing 20 units. The Surge Current Monitor monitors the current going through each unit under test at the time of the surge. If a unit under test breaks down or leaks, the Surge Current Monitor will identify the bad unit by lighting the corresponding LED. The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. In production testing we expect that most of the time the devices will pass. In the event that one should fail, the failed device would be removed and then all the parts would have ot undergo another surge test. Since most devices pass most of the time, simultaneous surge testing can be a real time saver.

  • Partial Discharge Testing Equipment

    AR700 - Scope T&M Pvt, Ltd.

    PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.

  • Wide-range High-power DC Power Supply

    IT6500 Series - I-TECH Electronic Co., Ltd

    With ITECH’s latest technology, the IT6500 series offers a full-featured high-performance power test solution. With fast response these DC power supplies provide users with a new level of power supply performance. From 800W to 30 kW, the whole series include more than 100 models. The maximum output voltage and current is up to 1000V and 1200A respectively. With its autoranging capabillity, it also has a super wide range of voltage and current applications. Users can choose the power supply that fits their testing requirements perfectly. In combination with the IT-E501 power dissipater unit, the current sinking capacity of IT6500C can be 100%, 200%, 300% and the power sinking up to 300% of the Sourcing capability. As a high-speed two-quadrant power supply, IT6500C (1800W-30kW) series has a priority function so as to realize high-speed current transition between power supply mode and electronic load mode, to achieve fast switching between sourcing and sinking current, even can achieve seamless switching under certain conditions. IT6512, IT6513 and IT6500C series power supplies provide built-in DIN40839 and ISO-16750-2 testing curves, support solar panel I-V curve simulation function.

  • Domestic Direct Reading Spectrometer

    CS-8610 - Wuxi Tianmu Instrument Technology Co., Ltd.

    1. Convenient, practical and reliable: unique combustion device, equipped with infrared detection system, direct connection, remote control operation.2 , patented burner design (using utility model patent technology)The burner electrode upgrading system adopts a spring structure, the electrode adjustment is convenient, and the double sealing ring guarantee the pressure balance in the furnace cavity without tempering.3 , to ensure accurate measurement results◆Using low-noise, high-sensitivity, high-stability pyroelectric infrared detectors.◆Specially-made new platinum infrared light source, continuous heating and high spectral efficiency.The modular design of the whole machine, the electronic circuit is highly integrated, which improves the reliability of the instrument.◆Industrial-grade integrated linear module power supply, stable output, no fault.◆The infrared detection part and the combustion furnace are connected by optical fiber, and cooperate with multi-level concealed isolation circuit to completely eliminate arc interference.◆Double filter device to reduce the impact of dust on the analysis results.4 , electronic balance is not quantitative sample: you can choose different brands of electronic balance, automatic online, to achieve non-quantitative weighing.

Get Help