Filter Results By:

Products

Applications

Manufacturers

Model

construction of a concept.

See Also: Modeling, Modelling, Modelers, Human Body Model, Charged Device Model


Showing results: 2566 - 2580 of 4104 items found.

  • Walk-In Altitude Test Chamber

    ACMAS Technologies Pvt. Ltd.

    WEIBER Altitude Test Chambers combine temperature and altitude to test basic components or subassemblies designed for use in a variety of industries. With altitude test chambers, user can control the temperature environment for testing while simulating various altitudes from site level to 100,000 feet (1.12kPa)High and low Temperature Altitude Test Chamber is used to test temperature and low-pressure altitude conditions simultaneously. All models are factory tested, with an ergonomic and maintenance cum user-friendly design.These CE approved test chambers are created with multi-layered insulation with double vapor barrier is of low 'K' factor, high density and of non-hygroscopic in nature. WEIBER test chamber are made in accordance with the international standard.Standard as well as customizable models are available. Walk in models are also available.

  • Tester for Voltage Regulators

    MS012 COM - MSG Equipment

    The device simulates installation of voltage regulator on faultless alternator in order to test its operating performance under different loads and modes, under various rotor resistance parameters. The handset tester conducts diagnostics of all existing types and models of voltage regulators.New types and models of voltage regulators can easily be added by updating software through USB-port. The equipmentis controlledby three encoders and a sensor on colored display. Diagnostics lasts about 2 minutes.

  • GPIB To Ethernet Instrument Interface

    ICS Electronics

    *ICS's 4865B GPIB to Ethernet Instrument Interface adapts instruments with Ethernet interfaces to GPIB test systems.*ICS's 4865B provides a VXI-11 compliant interface for instruments that support the VXI-11 protocol and a smart, user-configurable, raw socket protocol that accommodates most instruments that use raw sockets. The 4865B replaces our earlier Model 4865 and is 2x to 5x faster than the original Model 4865. Click here for the original 4865 webpage.

  • Turns Ratio Testers

    TRT Standard Series - IBEKO Power AB

    When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.

  • Motor Test for Stepping Motors

    MOTOMEA

    *Stable measurement: Since it uses Prony braking, this model provides stable measurement unaffected by moments of inertia and no coupling loss. In addition, the resulting measurements allow data correlation via the traditional double-balance method.*Precision measurement method: This model’s judgment of synchronization loss achieves high stability using algorithms developed by Sugawara Laboratories. Measurement mode can be chosen based on step angle. For pull-in torque, startup can be measured consistently from the holding state. Allows measurement at 1-Hz resolution.*Broad measurement range: This model offers a range of seven available measurement heads, from 0.5 N to 50 N, allowing use for high-precision measurements. Through selection and use of pulleys, this model can also be used to measure small motors of 0.5 mN·m or less or 500 mN·m motors. Pulley diameters and other settings are easily configured using a personal computer running Windows®. Note: Any of the seven available heads may be attached to a single measurement component.*High-visibility measurement data: Motor characteristics are easily ascertained on automatically plotted performance graphs. Measurement data can be overlaid up to four times. In addition, the cursor can be used to read accurate values from measurement points. Hard copies of data displayed on-screen can be printed from a personal computer.*Can be controlled using standard personal computers: Allows control of measurement operations and display and storage of data from a standard personal computer running Windows®. Data is stored in CSV-format files for compatibility with other software applications.

  • Varistor Testing

    EMC Partner AG

    Impulse generators with variable voltage and current outputs for testing disk varistors. Models designed for clamping voltage, energy absorption, surge withstand and combination wave testing.

  • Ground Fault Analyzers and Detectors

    Multi-Tech Industries, Inc.

    The Model 760 detects and locates accidental ground faults on both energized and de-energized power circuits including single phase, three phase, and DC ungrounded systems.

  • DHCP Tests

    InterWorking Labs, Inc.

    The Dynamic Host Configuration Protocol (DHCP) provides configuration parameters to Internet hosts. DHCP consists of two components: a protocol for delivering host-specific configuration parameters from a DHCP server to a host and a mechanism for allocation of network addresses to hosts. DHCP is built on a client-server model, where designated DHCP server hosts allocate network addresses and deliver configuration parameters to dynamically configured hosts. (Source: RFC 2131)

  • Dipole Antenna

    AD-100 - Com-Power Corporation

    The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.

  • Electronic Printers

    EP-100/EP-110 - Shimadzu Corp.

    Easy-to-Use Printers, Supporting Good Laboratory Practice The EP-100 and EP-110 electronic printers for Shimadzu balances are easy-to-use, provide time and signature information, and support Good Laboratory Practice (GLP). Supported balance models include: AP; AW-D, AUW, AUX and AUY; ATX and ATY; AT-R; UP; UW and UX; TX; TXB; BL; ELB; BW-K and BX-K; and the MOC63u moisture balance.

  • Megohm Meter

    Fieldpiece Instruments, Inc

    Digital Megohm Meter, model SMG5, is a compact standalone meter designed for checking HVAC compressor insulation. The SMG5 provides a 1000V voltage source, monitors current, and displays the resistance between the test points. Maximum current output is <1mA. It can be used to determine the condition of insulation from winding to ground in a motor, compressor, or transformer. Includes a case, alligator clip lead tip and leads with removable tips.

  • Operational Amplifiers

    Op Amps - Analog Devices Inc.

    For designs requiring operational amplifiers (op amps), Analog Devices' portfolio of high speed op amps and precision op amps provides a broad choice of products that deliver unmatched performance. Explore op amps by parameters, and find expert system-level advice on design problems with our amplifier reference designs (Circuits from the Lab®), design tools, selection guides, calculators, and SPICE models.

  • Preamplifier

    2721 - Georg Fischer Signet

    Pre-amplification is required to protect the output signal of pH and ORP electrodes from a wide variety of electromagnetic interferences common in industrial environments. Signet 2721 is used if remote pre-amplification is required (e.g. tank temperature >80oC) or connecting another manufacturer's electrode to the Signet 5700 or 8750 instrument. The Signet 2721 should be used with special order sensors built with cables (Signet models 277X-HT or 277X-1-HT).

  • Preset Break-Over Wrenches

    MMTB - Mountz Inc.

    The MMTB is miniature preset production torque wrench with a fixed head. The versatile wrench is available with different head configuration options, like open, box, flare, hex key and ratchet head. MMTB models are design to have one permanent head style attached to it. When the MMTB torque wrench achieves torque, the head breaks-over preventing the operator from overtorquing the fastener. To Order Call (408) 292-2214

  • Probes

    2800 Series - MicroSense, LLC

    Many sensor heads, or probes, are available for use with our 4800 series and 8800 series capacitive position sensor. The resolution of our capacitive position sensors is determined by a combination of the active sensing area of the probe, the measurement range, and the measurement bandwidth of the electronics unit (demodulator). Please refer to the Model 4810 data sheet for complete details on probe selection, including mechanical dimensions of our standard probes.

Get Help