Showing results: 4966 - 4968 of 4968 items found.
-
Model T300 -
Teledyne Monitor Labs
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
RNT-5A -
Neutronics Manufacturing Co.
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.
-
SDT-40KW -
Zhejiang Sandi Electric Co., Ltd
SANDI SDT series single-phase to three-phase converter, adopted SVPWM modulation control technology, which can convert ordinary single-phase power to industrial three-phase power. After through SDT series single-phase to three phase converter power conversion, the three-phase power output is standard pure sine wave, the harmonic distortion rate (THD) is less than 2%, totally meet the national standards of three-phase power quality, applicable to all types of load.The SDT series single-phase to three-phase converter can solve production inconvenience because of some areas with the three-phase electric power restrictions, also solved some user requirements that can?謒?apply for the three-phase electric because of space limitation.Features1) Using the fifth generation efficient IPM intelligent module from Japanese Mitsubishi, high efficiency and stable performance. It with powerful protection function, the protection for short circuit, over load, over temperature is more safe and reliable. It's service life can up to 15 years or more.2) Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customers can set start mode according to the type of their load. This function is very convenient for users and also reduce frequency converter?謒?usage, which reduced the cost of equipment investment, easy to connect wires and control.3) Pure sine wave output with good transient response less than 50ms, waveform distortion is very little, higher conversion efficiency and stable output voltage.4) Adopted low frequency transformer which ensure the input voltage and output voltage are completely electrical isolated to avoid interference.5) Using SVPWM space vector algorithms, high conversion efficiency, high instantaneous power and low losses conversion efficiency up to 94%.6) Output AC Power is suitable for all types of electric appliances, electric tools, electric motors etc. higher capability of driving load.7) Converter has the function of filtering the grid disturbance and interference at the same time, which is a good performance of stabilized voltage and frequency power, to provide a more stable and pure power supply environment for the backend devices.8) Output perfect protection function, with output over-voltage, overload, short circuit, over temperature, self-diagnosis protection and other protection.9) High conversion efficiency, high instantaneous power and low load loss.10) The input voltage, output voltage, frequency and phase can be custom made.SpecificationModel SDT-40KWIsolation mode Low Frequency TransformerAC InputRated voltage (Vac) 240V single-phase 60HZVoltage range (Vac) 190-270VInput current (A) 167AAC OutputRated power (KW) 40KWRated voltage 240V ± 2%Output phases Three-phase with Neutral wires (L1, L2, L3 + N)Rated current (A) 96AOutput frequency 60Hz ±0.05 (50HZ can be set)Waveform Pure sine waveVoltage accuracy Load balancing≤1%、Unbalanced load≤5%Waveform distortion rate (THD) Linear load≤2%、Nonlinear load≤3%Dynamic Response 5%,≤50ms (load 0~100%)Power Factor (PF) 0.99Inverter Efficiency ≧85%Electrical insulation properties 2000Vac、1 MinuteProtection FunctionOverload Ability 150%、10sProtection Input under voltage, overvoltage, output over-current, short circuit, overheating etc.Display LCD+LEDMethod of working Working continuouslyCooling method Intelligent fan coolingShort-circuit protection No automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protection IP20 (indoor)Working Altitude(m) ≤3000mWorking temperature (℃) -20~+50℃Relative humidity (℃) -25~+85℃Noise (1 meter) ≤60dBReference size: (W x D x H) 750×750×1480mmReference net weight (Kg) 340Kg