Showing product results. 4771 - 4785 of 5022 products found.
-
VGM - Alpha Lab, Inc.
The Vector Gaussmeter displays the true magnitude of the field at any location as well as the X, Y, Z components of up to 800 gauss. Also separately displays peak values of X, Y, Z, and magnitude. There is a sound alarm that determines the locations where the field magnitude exceeds user-set threshold. Because magnitude is measured, the orientation of the sensor (E-W, N-S, and up-down) is not important; this is unlike a 1-axis gaussmeter. With the VGM the user can set the alarm to 15 gauss (for example) and it will sound (simultaneous with a red light) whenever the field exceeds 15 gauss for at least 5 milliseconds. Using the meter this way, it is easy to make a map of the 15 gauss line (or for whatever threshold is set) around a strong magnet. When using the alarm, of a steel part can be rapidly scanned to show if any areas exceed the set threshold. Then the "peak hold" function can be interrogated, showing the peak values of X, Y, Z (including polarity) and magnitude that occurred during the scan. Peak hold also has a 5 millisecond response time.
-
ZGC - Alpha Lab, Inc.
The model ZGC zero gauss chamber reduces the environmental magnetic field (Earth field) to near zero inside the chamber. Any gaussmeter probe which is less than 9.4 mm or 0.370" diameter can be placed inside. The meter is then "zeroed", which means that it will read zero whenever the probe is subsequently placed in zero field. By using a zero gauss chamber, any offset error is therefore eliminated. The model ZGC is unique in that it contains a degausser (demagnetizer). This is situated between the inner and outer mu-metal shields. When the degauss button is pressed, any accidental magnetization of the chamber, no matter how strong, is erased. Accidental magnetization is a major problem with most zero gauss chambers and it has limited their use. If a magnet comes too close, the chamber will become "permanently" magnetized and will have an internal field that is typically 0.2 to 0.5 gauss. The chamber must then be degaussed because the Earth field is also around 0.5 gauss, so a magnetized zero gauss chamber will not significantly reduce the field.
-
Digital 250 - Pyrometer Instrument Company
The Pyrometer Digital 250-Contact digital thermometer is a rugged portable easy to read thermocouple pyrometer that utilizes interchangeable, reusable thermocouple tips on contact temperature measurement applications. These digital thermometer pyrometers are ideal for temperature sensor measurement using thermocouple thermometer K type thermocouples. Instrument temperature display accuracy to ± 0.3% of reading. The Digital 250 digital thermometer meter comes complete in a durable aluminum housing and is ready to use with a wide variety of thermocouples. The extension arm is constructed of 5/8″ chrome plated Brass Tubing. There are two versions of extension arms to choose from, either a direct connected 12″ long rigid arm or if you are taking temperature measurements in an awkward or hard to reach position, there is a flexible extension arm with a 12″ rigid arm that includes a bicycle grip type handle connected to 30″ stainless steel interconnecting armor cable to your Digital 250 for taking high temperature measurements in any position at a safe and comfortable distance.
-
Pacific Instruments, Inc.
Series 6000 digital I/O modules record signals from frequency counters, flow meters, encoders, discrete transducers, IRIG time, etc. which are often part of the test environment. These digital signals are time aligned and recorded alongside the system’s analog measurements. High density digital inputs provide an opportunity to easily include facility controls like switches, valve positions, relays, lights, etc. along with the test data. Series 6000 digital I/O modules also provide outputs generated by user command or automatically by Sequence, Alarms or DSP. User generated outputs are accomplished in software while sequencers can be programmed prior to a test and initiated by program or hardware control. Alarm conditions preprogrammed on the analog side can automatically generate digital outputs which are typically connected to facility control systems or PLCs. A DSP adds powerful real-time processing and is appropriate for PID control loops, derived parameter calculations and a variety of other real-time operations.
-
THW-L2 - Thermtest Instruments
Designed with speed and operational simplicity in mind, the Transient Hot Wire (THW-L2) Liquid Thermal Conductivity Meter is an advanced measurement system for direct determination of the thermal conductivity of liquids and pastes in accordance with ASTM D7896-19. In less than 2 seconds, a single measurement of small volumes of liquids and pastes can be accurately and precisely measured for thermal conductivity. Using a non-stationary measurement approach, the THW-L2 uses rapid test times to limit convective effects for samples with a wide range of viscosities. The THW sensor consists of a 60 mm heating wire that is fully inserted into an isothermal sample. A constant current source (q) is used to heat the sensor wire and the temperature rise is recorded by monitoring the change in electrical resistance of the wire. The slope (m) is determined from the plot of temperature rise vs. logarithm of time and is used in the calculation of thermal conductivity (λ). Liquid samples of high thermal conductivity will have a lower slope, while liquid samples with low thermal conductivity will have a higher slope.
-
LA-1 HC - Walter G. Legge Company Inc.
LA-1 HC Floor Conductivity Tester Hand Crank is an easy-to-use meter developed for accurately testing the conductivity of floors and equipment. The LA- 1 must be used regularly to monitor proper conductivity with NFPA code # 99. Regular use of the LA-1 will establish and maintain procedures for the proper maintenance of conductive floors, eliminate fire hazards, and provide a static free environment. A hand crank AC type generator provides a rectified DC test potential. Additionally, there are no brushes to wear out. The LA-1 has an easy-to-read scale that is selectively expanded electronically to assure accurate readings over the entire range of the instrument and the scale has a length of 3.75. This is 42% longer than typical competitive testers. The LA-1 uses 500V DC to test the resistance (in ohms) between two points. (NFPA Code #99) The meter comes ready-to-use (tin foil must be applied to bottom of weights). Simply follow the instructions for use and instantly obtain an accurate measurement. Choose electric or hand powered model.
-
ST-365TR - Standard Electric Works Co., Ltd
● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy.● Packaging...packed completely with AL-21 test leads, hFE leads, fuse, instruction manual.
-
ST-368TR - Standard Electric Works Co., Ltd
● Taut band movement.● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and dB measurement.● LCD check function.● Battery test function.● Continuity test function.● With stand...makes reading and measuring easy.
-
Bestone Industrial Ltd.
It can also be used as an Easy and Protable Meter. This data logger measures and stores up to 32,000 temperature(-35 to 80℃(-31~176℉)) readings. Some professional applications can be provided by the PC software DGraphTM. Logger status, alarm indication and low battery indication are via flashing red/green LED and yellow LED. The button on housing can be used to start logging, or confirm and clear LED alarm when LED alarm is hold status.
-
Lutron Electronic Enterprise Co., Ltd.
Radio frequency or “RF” refers to high frequency fields and microwaves emitted by microwave ovens, cell towers, cell phones, cordless phones, TV and radio broadcast towers, Wi-Fi, wireless computer devices, and other electronics. The electric and magnetic parts of RF fields are not separated, so you only need one meter to detect the RF field. RF is usually measured in units of microwatts per centimeter squared (μW/cm²).
-
ATI-100 - Matrix Test Equipment Incorporated
Now, with our ?New? Model ATI-100 you can turn your existing Matrix Signal Generator and Switchable Filter Bank into a full-blown DTS (Distortion Test System). Plug and play is the word, just plug in your Multiple Frequency Signal Generator, Switchable Filter Bank, Spectrum Analyzer, Oscilloscope, Power Meter, Frequency Counter, etc. to allow the following automatic testing with a single insertion of DUT (device under test
-
Energy Gear - Ducati energia S. p. A.
Datalogger web gateway for energy monitoring. with data reading from energy meters, pulse counters and different sensors , data logging on internal memory , data transmission to web cloud or to local server or PC. Communication via intranet, internet or 3G cellular line.It’s intended for the energy management of industrial plants, office branches, companies with wide geographical distribution, unattended facilities of production plants or services, Energy Service Company
-
Model T300M - Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
AJIT Electronics Co.
The protective devices such as relays, overload coils, circuit breakers must be checked regularly to ensure that, they are always ready to operate correctly. If a fault occurs in the equipment, which they are protecting, routine relay testing will quickly detect the faulty, incorrectly adjusted protection circuits correctly. It is usually necessary to measure its operating time. The micro controller based time interval meter is used for this purpose in all AJIT brand relay testers.
-
Konrad Technologies GmbH
RF and wireless turnkey test solutions for high-performance measurements at microwave frequencies.This RF-system is able to test products in an 868 MHz frequency range, for example radio systems, heat-cost distributors, water and heat meters. It is designed as a semi-automatic manual work station and allows parallel placement and automatic functional test of two-times two DUTs in a tandem arrangement. To guarantee a stable measuring result, the test system has two identical RF-chambers