  • 10 Digit Rate/Batch Counter (Analogue)

    CS2-TM-Analogue - Chuan Sheng Electronics Co., Ltd.

    The CS2-TM Totalizer controller provide high accuracy measurement, display, control and communication (Modbus RTU mode) of 0~10V/4~20mA from flow meter or mV from Shunt for Amp-Hour.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.

  • Handheld Cable Fault Locator

    TM800H - T&M Tools Limited Co

    TM800H Handheld Cable Fault Locator adopts TDR (Time Domain Reflection), new signal process and data collection technology. It can locate the distance of cable break and mix faults accurately. TM800H can be widely used in the communication installation, maintenance and general wiring. It can troubleshoot not only the local Telco-cable, but also Network cable. Its high sampling rate makes the measurement dead zone as narrow as 1 meter. This makes it a straightforward, user-friendly test solution.

  • Acoustic Calibrators

    Castle Group Ltd.

    When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.

  • Premise Toner Drop Cable Continuity Tester

    RPT-AAA Series - Ripley Tools LLC

    Electronic testing tool designed to check the circuit integrity in new or installed cable up to 5,000 feet (1,500 meters) in length LED indicates DC shorts, splitters & other self-grounding devices in cable while a loud audio tone identifies the line carrying the signal Equipped with a right angle male push-on connector to maneuver in tight areas & a female push-on connector for speed toning Tool includes a pocket clip & (1) AAA 1.5V battery.

  • 1000 Amp Clamp with IR Thermometer

    FLIR CM78 - Teledyne FLIR

    The FLIR CM78 is a True RMS industrial clamp meter for the electrician who works on high-powered equipment and temperature systems and needs a safe, capable combination tool. An integrated IR thermometer provides fast non-contact measurements on panels, conduits, and motors. FLIR Tools Mobile connects the FLIR CM78 to your compatible smartphones and tablets via Bluetooth®, and METERLiNK® technology wirelessly integrates electrical readings on your infrared image with FLIR thermal cameras.

  • Signa; Generator

    MAG-203AD - MCH Instruments Co.,Ltd.

    Features:*Signal frequency:0 .1Hz-2Mhz, continuously variable*Wave form: square,sine*Output attenuator:0dB, 20dB, 40dB,60dB*Output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*Rising and falling edge of square not more than 35ns*Sine distortion less than 1%,amplitude -frequency characterstic:±0.3dB within 100khz, ±1dB above 1Mhz*Frequency meter: 10Hz-30Mhz*Power supply : AC 220V

  • Hygro-Thermometer Psychrometer

    Extech RH300 - Extech Instruments Corporation

    The RH300 is a compact meter that is ideal for field applications. Simultaneously displays relative humidity (10% to 90% RH), air temperature and dew point or wet bulb. Calculates T1-T2 differential (air temperature minus external probe temperature) using optional probe (TP890), and T2 minus dew point. Built-in protective sensor cap. Other features include Data Hold, Auto Power Off, and MAX/MIN reading. Complete with 2 AAA batteries.

  • Tube Tester / Tube Checker

    RM 1 - Beck Elektroakustik

    Using the RM 1 Tube Checker it is immediately possible to do an exact plate current measurement without doing the often very toilsome procedures mostly necessary with classical devices. Put the electron tube, which should be measured, simply into the accordingly marked test socket, switch the equipment on, select the socket by using the rotary switch (it is indicated by a LED), wait for approx. three minutes till the tube is working stabile and read off the value on the panel meter.

  • Earth Leakage Relay

    Nippen Electrical Instruments Co.

    NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.

  • Low Current Probe 80A

    695 - Electronic Specialties Inc.

    Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.

  • Tap Changer Analyzers & Winding Ohmmeters

    IBEKO Power AB

    Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints

  • 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module

    NI-9227 / 781099-02 - NI

    50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The NI‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a … C Series Voltage Input Module, the NI‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics.

  • 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module

    NI-9227 / 781099-01 - NI

    50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The NI‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a … C Series Voltage Input Module, the NI‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics.

  • Portable Multifunction Calibrator

    M143 - Clarke-Hess Communications Research

    The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.

  • Frequency Shaped Isotropic Electric Probes

    PI-SH-FCC, PI-SH-ICNIRP - EMC Test Design, LLC

    An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.