Filter Results By:

Products

Applications

Manufacturers

Meters

sense, display, measures; gas, water, electricity, particles, vibration, light or quanta.

See Also: Sensors, Measurement


Showing results: 4606 - 4620 of 4968 items found.

  • Vector/Magnitude Gaussmeter

    VGM - Alpha Lab, Inc.

    The Vector Gaussmeter displays the true magnitude of the field at any location as well as the X, Y, Z components of up to 800 gauss. Also separately displays peak values of X, Y, Z, and magnitude. There is a sound alarm that determines the locations where the field magnitude exceeds user-set threshold. Because magnitude is measured, the orientation of the sensor (E-W, N-S, and up-down) is not important; this is unlike a 1-axis gaussmeter. With the VGM the user can set the alarm to 15 gauss (for example) and it will sound (simultaneous with a red light) whenever the field exceeds 15 gauss for at least 5 milliseconds. Using the meter this way, it is easy to make a map of the 15 gauss line (or for whatever threshold is set) around a strong magnet. When using the alarm, of a steel part can be rapidly scanned to show if any areas exceed the set threshold. Then the "peak hold" function can be interrogated, showing the peak values of X, Y, Z (including polarity) and magnitude that occurred during the scan. Peak hold also has a 5 millisecond response time.

  • Zero Gauss Chamber

    ZGC - Alpha Lab, Inc.

    The model ZGC zero gauss chamber reduces the environmental magnetic field (Earth field) to near zero inside the chamber. Any gaussmeter probe which is less than 9.4 mm or 0.370" diameter can be placed inside. The meter is then "zeroed", which means that it will read zero whenever the probe is subsequently placed in zero field. By using a zero gauss chamber, any offset error is therefore eliminated. The model ZGC is unique in that it contains a degausser (demagnetizer). This is situated between the inner and outer mu-metal shields. When the degauss button is pressed, any accidental magnetization of the chamber, no matter how strong, is erased. Accidental magnetization is a major problem with most zero gauss chambers and it has limited their use. If a magnet comes too close, the chamber will become "permanently" magnetized and will have an internal field that is typically 0.2 to 0.5 gauss. The chamber must then be degaussed because the Earth field is also around 0.5 gauss, so a magnetized zero gauss chamber will not significantly reduce the field.

  • 6000 Series Digital I/O Modules

    Pacific Instruments, Inc.

    Series 6000 digital I/O modules record signals from frequency counters, flow meters, encoders, discrete transducers, IRIG time, etc. which are often part of the test environment. These digital signals are time aligned and recorded alongside the system’s analog measurements. High density digital inputs provide an opportunity to easily include facility controls like switches, valve positions, relays, lights, etc. along with the test data. Series 6000 digital I/O modules also provide outputs generated by user command or automatically by Sequence, Alarms or DSP. User generated outputs are accomplished in software while sequencers can be programmed prior to a test and initiated by program or hardware control. Alarm conditions preprogrammed on the analog side can automatically generate digital outputs which are typically connected to facility control systems or PLCs. A DSP adds powerful real-time processing and is appropriate for PID control loops, derived parameter calculations and a variety of other real-time operations.

  • Floor Conductivity Tester Hand Crank

    LA-1 HC - Walter G. Legge Company Inc.

    LA-1 HC Floor Conductivity Tester Hand Crank is an easy-to-use meter developed for accurately testing the conductivity of floors and equipment. The LA- 1 must be used regularly to monitor proper conductivity with NFPA code # 99. Regular use of the LA-1 will establish and maintain procedures for the proper maintenance of conductive floors, eliminate fire hazards, and provide a static free environment. A hand crank AC type generator provides a rectified DC test potential. Additionally, there are no brushes to wear out. The LA-1 has an easy-to-read scale that is selectively expanded electronically to assure accurate readings over the entire range of the instrument and the scale has a length of 3.75. This is 42% longer than typical competitive testers. The LA-1 uses 500V DC to test the resistance (in ohms) between two points. (NFPA Code #99) The meter comes ready-to-use (tin foil must be applied to bottom of weights). Simply follow the instructions for use and instantly obtain an accurate measurement. Choose electric or hand powered model.

  • Temperature Data Loggers

    Bestone Industrial Ltd.

    It can also be used as an Easy and Protable Meter. This data logger measures and stores up to 32,000 temperature(-35 to 80℃(-31~176℉)) readings. Some professional applications can be provided by the PC software DGraphTM. Logger status, alarm indication and low battery indication are via flashing red/green LED and yellow LED. The button on housing can be used to start logging, or confirm and clear LED alarm when LED alarm is hold status.

  • Datalogger Web Gateway

    Energy Gear - Ducati energia S. p. A.

    Datalogger web gateway for energy monitoring. with data reading from energy meters, pulse counters and different sensors , data logging on internal memory , data transmission to web cloud or to local server or PC. Communication via intranet, internet or 3G cellular line.It’s intended for the energy management of industrial plants, office branches, companies with wide geographical distribution, unattended facilities of production plants or services, Energy Service Company

  • Mid-Range Gas Filter Correlation CO Analyzer​

    Model T300M - Teledyne Advanced Pollution Instrumentation

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.

  • Automatic Relay Tester

    AJIT Electronics Co.

    The protective devices such as relays, overload coils, circuit breakers must be checked regularly to ensure that, they are always ready to operate correctly. If a fault occurs in the equipment, which they are protecting, routine relay testing will quickly detect the faulty, incorrectly adjusted protection circuits correctly. It is usually necessary to measure its operating time. The micro controller based time interval meter is used for this purpose in all AJIT brand relay testers.

  • Antenna Analyzer

    iP60z - iPortable

    The new iP60z iPortable™ Antenna SWR Analyzer is designed for field use. This compact battery powered unit has an easy to read frequency display and measures SWR and impedance in the HF Band and VHF 6 Meter band. The SWR readings quickly show you the actual VSWR measurement and Magnitude of the impedance (Z). This is the easiest way to adjust your portable or base station antenna to be best matched for your radio.

  • Grain Moisture Analyser

    Perten AM5200 - Calibre

    The AM5200 is a bench top moisture meter providing moisture and specific weight measurements in just 10 seconds. The high frequency technology penetrates deep into samples, providing more accurate analysis, regardless of temperature or crop type. This particular machine draws upon Perten’s extensive research and development with over 1,000 different types of grain moisture testing equipment, to offer unmatched analysis in terms of accuracy, repeatability and reliability.

  • Palm-top DC Power Supply

    R4K-36 Series - MATSUSADA Precision Inc.

    R4K-36 series is the most compact power supply among the family of ultra compact bench-top DC supply, RK series. In addition to its impressive compact size, 4-digit voltage and current meters make circuit testing easier. With capability of digital interface, it is also ideal for production line of electrical components and for quality inspection. R4K-36 is an innovative power supply, and more than just an ordinary DC regulated supply.

  • Protective Relay Test Set

    K1066i - KINGSINE Electric Automation Co., Ltd.

    1. Adopts 6.4 large LCD screen, and provided with VGA video interface, making it available to connect to projector for training;2. With alarm function of housing grounding testing and external voltage input, to guaranty personal security;3. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A(Poleless and adjustable);4. Two in one of meter and source, with function of both internal and external testing, self-calibration, oscillograph,

  • Level Test (& Calibration) Rig

    LTR600 Series - Smartech Inc.

    Level Test & Calibration Rig – a boon to Petrochemical Refineries & other process Industries – relies on state of the art simple design for Primary & Interface liquid level testing & calibration of various types / models of Level Measurement (& control) devices including Float / Displacer / Radar / Capacitance / Ultrasonic / Magnetic – for both In-built & External Chamber types. Available Ranges / Span are 1000mm / 1500mm & 2000mm (1 / 1.5 & 2 Meters).

  • Power Metering Precision Shunt Resistore

    PMS - RARA Electronics Corporation

    These components have E-Beam welded manganese-copper alloy elements giving high strength, stability and reliability. Low thermal EMF and TCR. Small size and minimal power loss. Minimal heat generation and surface temperature due to small total resistance. Proprietary processing technique allows very low resistance values. Ideally suited for KWh meters and sampling sensor shunts. These units are also suitable for custom design.

  • AC Line Splitter

    1937 - Peaceful Thriving Enterprise Co Ltd

    The AC line splitter is a helpful testing device for electrician. Electrician can measure the current with clamp meter through the X1 and X10 measuring rings. X1 is 1:1 measurement, and X10 is ten times (1:10) of the actual current, which is helpful for small current measurement. This device also combines the function of socket tester and GFCI tester, which means electrician can use this tester to test socket and load at the same time.

Get Help