  • 1000 Amp Clamp with IR Thermometer

    FLIR CM78 - Teledyne FLIR

    The FLIR CM78 is a True RMS industrial clamp meter for the electrician who works on high-powered equipment and temperature systems and needs a safe, capable combination tool. An integrated IR thermometer provides fast non-contact measurements on panels, conduits, and motors. FLIR Tools Mobile connects the FLIR CM78 to your compatible smartphones and tablets via Bluetooth®, and METERLiNK® technology wirelessly integrates electrical readings on your infrared image with FLIR thermal cameras.

  • Waveguide Power Sensor

    R8486D - Keysight Technologies

    Excellent SWR for reducing mismatch uncertainty50 MHz calibration port Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 26.5 GHz to 40 GHz Diode power sensing element

  • Waveguide Power Sensor

    Q8486D - Keysight Technologies

    Excellent SWR for reducing mismatch uncertainty50 MHz calibration port Accurate calibration and traceability to US National Institute of Standards and Technology (NIST) millimeter-wave sensor calibration Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters, plus the E1416A VXI and discontinued 70100A and 43X power meter Accurate average power measurements over -70 to -20 dBm Frequency range 33 GHz to 50 GHz Diode power sensing element

  • Geo-electrical Resistivity Logging Exploration System

    Langeo Co., Ltd.

    Resistivity logging measures the subsurface electrical apparent resistivity, which is the ability to impede the flow of electric current. This helps to differentiate between formations filled with salty waters (good conductors of electricity) and those filled with hydrocarbons (poor conductors of electricity). Resistivity and porosity measurements are used to calculate water saturation. Resistivity is expressed in ohms or ohms\meter, and is frequently charted on a logarithm scale versus depth because of the large range of resistivity. The distance from the borehole penetrated by the current varies with the tool, from a few centimeters to one meter.

  • LiFi HotSpot Evaluation Kit

    Fraunhofer IPM

    The Li-Fi HotSpot Evaluation Kit allows the establishment of an optical wireless bidirectional point-to-point full-duplex data connection over medium distances in the meter range. Data rates of up to 1 GB/s are supported at a distance of up to 5 meters. The kit consists of two Li-Fi HotSpots, two CAT-6 cables (RJ45), two external power supplies and a user manual. Users can thus get to know the technical advantages of Li-Fi technology with little effort and test and evaluate them in their own network or environmental conditions.

  • Dust Monitoring System

    CDMS-1000 - Focused Photonics Inc.

    CDMS-1000 is designed with light scattering technology for continuous real-time measurement of particulate concentration along with noise and meteorological parameters. This combination consists of a particle analyzer, camera, sound level meter, and GPRS module.

  • Network Analyzer, Lan Tester, LED

    72-6290A - Tenma

    The 72-6290A is a multi-modular Cable Tester (LAN Tester) with LED meter display. Requires 9V battery for this modular cable tester. Used with RJ-45, RJ-12, RJ-11 connectors and USOC4, USOC6, USOC8 cables.

  • Network Analyzer, Tester, RJ45/BNC, LED

    72-9940 - Tenma

    The 72-9940 is a RJ45 Cable Tester with LED meter display. The tester easily tests RJ45 and BNC network cables. It features remote testing which allows to test cables that are terminated at separate locations.

  • 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module

    NI-9227 / 781099-01 - NI

    50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The NI‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a … C Series Voltage Input Module, the NI‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics.

  • 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module

    NI-9227 / 781099-02 - NI

    50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The NI‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a … C Series Voltage Input Module, the NI‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics.

  • Absolute Multiline Technology

    Etalon AG

    The Absolute Multiline technology is a revolutionary solution for the absolute precision measurement of distances up to 30 m with a measurement uncertainty of 0.5 μm per meter, simultaneously up to 124 channels. Unlike conventional interferometers, the measuring beam can be interrupted at any time without loss of accuracy. Within fractions of a second, the absolute distance is determined again. Due to this globally unique system properties, the patented Absolute Multiline technology takes metrology automation in the production area to a new level.

  • Cable Electric Resistance Tester

    MR 270 C-A - Schuetz Messtechnik GmbH

    The MR270C-A is specially designed for electric resistance measurements in cable industry applications and inductive loads (transformers, motors). It is perfectly fit both for measuring the meter resistance in connection with a corresponding resistance measurement holding device or for final acceptance control of power cable reels. In the case of cable reels, which often have a cable length of several kilometers, both the compensation of the inductive component and the ability to perform measurements in the presence of high noise levels are important. This also applies to the winding resistance of transformers and motors.

  • Cable ID & PoE Tester

    PK-170 INNOTESTER PRO - Pansco, Ltd

    INNOTESTER PRO combines the functions of a smart cable tester, network tester, port identifier and organizer with the capability to identify up to 100 cables run at a time, and 8 Test + ID remotes allows one person to test 8 cables run up to 600 meters. Tone mode, transmits 2 powerful tones for tracing inactive and active network cables on a Switch or HUB. More effectively tracing at patch panel, termination blocks or hidden within bundles.

  • Coating Thickness Gauge

    MEGA-CHECK Pocket - List Magnetik GmbH

    The new MEGA-CHECK Pocket coating thickness gauges use digital measuring probes in which the analog signals are digitized directly in the probe and transmitted over the digital probe cable to the meter. This new technology is very trouble-free and allows for very accurate, repeatable measurements. The probe cable is both sides (control unit and probe) and is therefore extremely easy, because if a cable breaks, the cable must only be replaced in case. The practical format of the housing with rubber reinforced sides, is hardly bigger than the probe.

  • Component Test Scanner

    Model 13001 - Chroma ATE Inc.

    Support component test scanningSupport 8 slots for plug-in (removable), up to 320 channels for one unitOption A130007 40 channels scan module, input up to 500VDC for IR test without switchingMax. 8 salve units for multiple scanner (master/slave interface)Support Chroma LCR meterSupport Chroma 3302/3252/11025 turn ration functionSupport 11200 CLC/IR meter for IR testStandard RS-232, GPIB and USB interface13001 can be installed in Chroma Component ATE model 8800Support ICT applications

Get Help