Showing product results. 3031 - 3045 of 5045 products found.
-
E4982A - Keysight Technologies
The E4982A LCR Meter provides the best performance for the passive component manufacturing such as SMD inductors and EMI filters, where impedance testing at high frequencies (1 MHz to 300 M/500 M/1 G/3 GHz) is required. Not only for the manufacturing, the E4982A can also be utilized for R&D, quality assurance with the powerful functions such as list measurements.
-
Extech CO15 - Extech Instruments Corporation
Check CO levels up to 999ppm with the push of a button using Model CO15. An audible alarm indicator will continuously beep starting at 25ppm (preset warning level - value can be adjusted) and the display will flash until the CO level goes down to normal range. A backlight on the display can be used for low light areas. The meter comes complete with batteries, wrist strap, and pouch.
-
9107A - Innovative Products of America
The #9107 Electric Brake Force Meter with Dynamic Load Simulation and Circuit Testing (patents pending) is designed for use on 7-spade equipped vehicles. This new technology automatically recognizes the electronic signature of both Integrated (ITBC) and aftermarket Trailer Brake Controllers, simulates trailer load and displays real-time, brake-controller output gain and application time. It can quickly troubleshoot truck-side tow circuits, e.g., tail lights, turn signals, 12V+, reverse and ground condition and the 25 ft. cable allows for one-man, in-cab testing.
-
Extech EX623 - Extech Instruments Corporation
This TRMS AC/DC Clamp Meter has dual thermocouple inputs for T1, T2, T1-T2 Differential Temperature measurement plus a built-in Infrared Thermometer with laser pointer for locating hot spots and NCV Detector. Additional features include: DC micro-amp function for flame rod measurements, Diode open circuit voltage of 2.8 Volt, Data Hold plus fast Peak Hold for capturing current surges at motor startup, and capacitance measurement to 40mF. Comes complete with test leads, 9 Volt battery, two Type K bead wire Temperature probes and carrying case.
-
HD-200FL - HORIBA, Ltd.
Optical dissolved oxygen sensor with no electrolyte replacement and rugged membrane.Highly intelligent, including automatic recognition of membrane properties when replacing the sensor cap.The HD-200FL is an optical (fluorescent) dissolved oxygen meter suitable for monitoring aeration tanks used for sewage treatment, effluent treatment, and other processes. Compared to conventional membrane polarographic type sensors, there is no need for electrolyte (internal fluid) replacement or warming, up. Characteristics of optical sensors are utilized to realize unequaled, improvement in ease of maintenance and reduction in running costs. Moreover, it features enhanced user-friendliness, with sensor caps that have built-in memory and a membrane replacement notification function.
-
FW1 - North Atlantic Industries
The FW1 provides IEEE 1394 (Firewire) high-speed serial communications. The module is provided with a direct PCIe interface to the local (on-board) processor, or, an external host processor for board platforms that support external PCIe connectivity. These module(s) are not supported with the classic memory register-based NAIBrd Software Support Kit (SSK) API libraries. These communication function modules support device control and management via standard native OS (Linux) FireWire device driver.
-
FW2 - North Atlantic Industries
The FW2 provides IEEE 1394 (Firewire) high-speed serial communications. The module is provided with a direct PCIe interface to the local (on-board) processor, or, an external host processor for board platforms that support external PCIe connectivity. These module(s) are not supported with the classic memory register-based NAIBrd Software Support Kit (SSK) API libraries. These communication function modules support device control and management via standard native OS (Linux) FireWire device driver.
-
-
Adafruit
For precision temperature sensing, nothing beats a Platinum RTD. Resistance temperature detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature changes, basically a kind of thermistor. In this sensor, the resistor is actually a small strip of Platinum with a resistance of 100 ohms at 0C, thus the name PT100. Compared to most NTC/PTC thermistors, the PT type of RTD is much most stable and precise (but also more expensive) PT100's have been used for many years to measure temperature in laboratory and industrial processes, and have developed a reputation for accuracy (better than thermocouples), repeatability, and stability.
-
PRS-801B - Prostat Corporation
- Accurate Wide Range Resistance Measurements: 0.01 Ω to 2.00x1014 Ω- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Variable Voltage 0.1 mv to 9.99 V for low resistance measurements- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Auto Resistance Range Control- Auto Test Voltage Control- Uses a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- 999 Data Set Memory- Download to Excel® in Batches or Individual Measurements with Prostat Connect 2.0- Uses Micro USB Cable for Charging and Downloading Data- Charges in 2 Hours- 2-year Limited Warranty on Main Instrument
-
HC-200F - HORIBA, Ltd.
HC-200F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.
-
HC-300F - HORIBA, Ltd.
HC-300F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.
-
HD-200 - HORIBA, Ltd.
HD-200 connects the DO (Dissolved Oxygen) sensor (DO-1100) and measures the DO in the sample water.The measurement method is membrane type polarography method. It is suitable for monitoring DO in wastewater treatment or aquarium for aquaculture.
-
HD-300 - HORIBA, Ltd.
HD-300 connects the DO (Dissolved Oxygen) sensor (DO-1100) and measures the DO in the sample water.The measurement method is membrane type polarography method. It is suitable for monitoring DO in wastewater treatment or aquarium for aquaculture.
-
EXFM-ONE - HORIBA, Ltd.
EXFM-ONE employs an ultrasonic method for measuring exhaust gas flow rates directly from a vehicle or engine. The unit can be used for various applications such as real time mass measurement of raw exhaust gas combined with MEXA-ONE (Motor Exhaust Gas Analyzer), or for Particulate Matter/emission measurement combined with partial flow dilution system such as MDLT (Partial Flow Dilution Tunnel) or BMD (Bag Mini Diluter). Fuel consumption evaluation is also available when EXFM-ONE is paired with an optional air-to-fuel ratio (AFR) analyzer.