Filter Results By:

Products

Applications

Manufacturers

Measurement

an acertained value.

See Also: Metrology, Instrumentation, Sensors, Meters, Stability


Showing results: 9916 - 9930 of 10608 items found.

  • DCA Equivalent-time Sampling Oscilloscopes

    Keysight Technologies

    Equivalent-time (sampling) oscilloscopes are also known as digital communication analyzers (DCA). They are designed to visualize and analyze the analog properties of high-speed signals used in data center and wireline telecom applications. The Keysight DCA platform features a wide variety of optical, electrical, and TDR/TDT modules, compliance applications, and a common FlexDCA user interface to ensure more efficient testing in both R&D and manufacturing. Due to an ultra-low jitter and low-noise acquisition system, the Keysight DCA series provides industry-leading measurement accuracy for high-speed digital designs including 400G/800G Ethernet and Fibre Channel.

  • sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    781210-01 - NI

    Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • Test Leads

    AL-34WB 10A - Standard Electric Works Co., Ltd

    ● Wire length: 1m approx.    Silicone insulated wire (700mm) with wire connected to straight input plugs (150mm PVC wire), and wire for clamp (150mm PVC wire).● Outside diameter of silicone insulated wire: 6.4mm   Outside diameter of PVC wire: 4mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 10A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Low Resistance Ohm Meter

    6237 DLRO - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measure down to 1μΩ.● 6 ranges from 2.000mΩ to 200.0Ω.● Maximum resolution of 1μΩ.● Three test currents with over-temperature protection.● Four terminal measurement.● Protection against inadvertent connection to over- voltage. (crow bars for current and voltage)● Clear & large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave™ Inside.● EnerSave™ Auto-hold.● EnerSave™ Auto-off.● Rechargeable battery operated● Robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.

  • 4 Wire Earth Resistance & Resistivity Tester

    4236 ER - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Earth resistivity (ρ) test.● Earth testing at 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test, 3-Wire test, 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● 200 measurement results can be saved in the memory and recalled on the display.● Interval between auxiliary earth spikes is 1.0~50.0m.● Optical USB to RS-232 data transmission.● The stored data can be transferred to a PC.● 2 optical LEDs are built-in for data transfer.

  • Test Leads

    AL-34WB - Standard Electric Works Co., Ltd

    ● Wire length: 1.2m approx.    Silicone insulated wire (1000mm) with wire connected to straight input plugs (130mm PVC wire), and wire for clamp (100mm PVC wire). ● Outside diameter of silicone insulated wire: 5mm   Outside diameter of  PVC wire: 3.5mm● Input plug color: Red•Green•Black•Blue  ● Current rating: 5A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031  CAT IV 300V

  • Digital ELCB (RCD) Tester

    2712 EL - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.

  • LXI Low Thermal EMF Matrix 1-pole 42x33

    60-510-002 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • sbRIO-9264, Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module

    781119-01 - NI

    Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The sbRIO‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the sbRIO‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection. Non-enclosed modules are designed for OEM applications.

  • PCI-4461, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 2-Input/2-Output Sound and Vibration Device

    779307-01 - NI

    The PCI‑4461 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous two-channel dynamic signal generation and simultaneous two-channel dynamic signal acquisition with six gain settings to configure the input range. The PCI‑4461 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.

  • PXIe-5654, 250 kHz to 20 GHz, PXI RF Analog Signal Generator

    784777-01 - NI

    PXIe, 250 kHz to 20 GHz, PXI RF Analog Signal Generator - The PXIe-5654 features a combination of exceptional phase noise and frequency tuning time. These features address applications such as blocker test/receiver desensitization, high-performance intermodulation distortion measurements, and various electronic warfare applications. The PXIe-5654 is designed to meet the challenging requirements of RFIC characterization, satellite test, and radar applications. Some PXIe-5654 options include a PXIe-5696 Amplitude Extender Module. The PXIe-5696 supports a frequency range of 250 kHz to 20 GHz and an extended amplitude range up to 27 dBm.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785996-01 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    779994-02 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9235, 10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785995-01 - NI

    10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9235 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9235 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-02 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

Get Help