Filter Results By:

Products

Applications

Manufacturers

Luminance

The photometric measure of luminous power.


Showing results: 46 - 60 of 68 items found.

  • Display Color Analyzer

    Model 7123 - Chroma ATE Inc.

    Luminance and chromaticity measurement of Color Display0.005 cd/m2low luminance measurement (A712301)Wide luminance range: 0.0001 to 25,000 cd/m2 (A712301) 0.01 to 200,000 cd/m2 (A712302)High accuracy measurementMaximum 9 display modes: xyY, TΔuvY, u’ v’ Y, RGB, XYZ, Contrast, ProgramAble to control Video Pattern Generator and UUT (Unit Under Test)Built-in contrast measurement function to calculate the contrast ratio directlyEquipped with programmable test items that can complete the planned tests with one single buttonSupport USB flash disk that can copy the test procedures to other station for useJudgment function embedded to judge the test result automatically with one single buttonCalibration period setting and reminding functionMemory for storing 100 channels of standard color data and calibration dataBuilt-in flat display calibration data LCD-D65 & LED-D65* to be applied for chromaticity measurement instantlyOptional display white balance alignment system can be used to integrate all optical test stations to one single station

  • Digital Screen Checker

    Harkness Screens International Ltd

    The low-cost digital cinema luminance meter for accurately measuring screen brightness. Now available, the Digital Screen Checker is an ideal tool for projection managers / projectionists or service engineers to monitor screen brightness and check lamp life. The Digital Screen Checker from Harkness Screens helps exhibitors to ensure that their presentations remain at optimum levels and ensure DCI-compliancy.

  • Analog Oscilloscope

    MCH Instruments Co.,Ltd.

    Is a measurement apparatus capable of visually depicting regular changes in electrical activity, such as an electrical current or signal. The resulting data appears as a waveform drawn on a graph with two axes, where the horizontal X axis represents time and the vertical Y axis indicates voltage. In addition, the luminance of the waveform itself is often referred to as the Z axis, which demonstrates the intensity of the activity measured.

  • Photometers & Colorimeters

    Instrument Systems Optische Messtechnik GmbH

    A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.

  • Lamp-Based Calibration Light Sources

    Gamma Scientific Inc.

    Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.

  • Spectroradiometer

    SR-Series - RayClouds Photoelectric Technology Co.,Ltd.

    SR-Series Spectroradiometer is equipped with resolution detectors of different pixel levels, particularly adding a spectroscopic measurement mode, which provides optional specific wavelength intervals for data analysis of the measured luminance, chrominance, color temperature, spectroscopy, etc. Cooperated with ProICM professional analysis software, it can perform high-speed and high-precision measurement of micro luminous surfaces, and provides a new and practical optimization scheme of two-dimensional spectroscopic test.

  • Smart G-Scope

    Dou Yee Enterprises (S) Pte Ltd

    Auto focus digital microscope & telescopeReal fast auto focus by using liquid lensInfinity(x10) ~ Contact (x250) hole area auto focus by changing mode switchAuto focus & manual focus functionChangeable various End caps to support 3pi coner end capHigh luminance OLED displayInfrared wireless controlSupport Android & Windows (XP, Win 7, Win 8)Various image filters & digital zoom functionSpecial design for portablility (aluminum case) No battery neededProvide software for Android and PC

  • Isolation Amplifier Analog Output

    Renesas Electronics Corp.

    This coupler is an optically coupled isolation amplifier that uses an IC with a high-accuracy sigma-delta A/D converter and a GaAIAs light-emitting diode with high-speed response and high luminance efficiency on the input side, and an IC with a high-accuracy D/A converter on the output side. This coupler is designed specifically for high common mode transient immunity (CMTI) and high linearity (nonlinearity) applications, making it ideal for current sensing in motor drives.

  • Goniophotometer

    PIMACS CO., LTD.

    A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.

  • LCD Display Optical Measurement System

    RayClouds Photoelectric Technology Co.,Ltd.

    LCD display optical characteristics automatic measurement system is mainly used in LCD, LED screen, OLED screen, FPD, Mini LED, Micro LED and various new luminous materials.LCD display optical characteristic automatic measurement system supports the test of optical performance parameters such as viewing angle, luminance, uniformity, contrast, chrominance, response time, flicker, and refresh rate, etc.

  • Isolation Amplifier Digital Output

    Renesas Electronics Corp.

    This coupler is an optically coupled isolation amplifier that uses an IC with a high-accuracy sigma-delta A/D converter and a GaAIAs light-emitting diode with high-speed response and high luminance efficiency on the input side, and an IC with a digital signal (MDAT, MCLK) output function on the output side. This coupler is designed specifically for high common mode transient immunity (CMTI) and high linearity (nonlinearity) applications, making it ideal for current sensing in motor drives.

  • Imaging Colorimeters

    Westboro Photonics

    Westboro Photonics offers high resolution, high performance imaging colorimeters to meet the needs of manufacturers for several key applications: Computer and cell phone keyboards: automatic measurement, identification and pass/fail analysis for luminance and chromaticity of backlit glyphs and other lit elements. Beam pattern analysis of the luminous intensity distribution of lamps and LEDs. Avionic light plate panel balancing. Transportation, architectural and municipal lighting and signage.

  • Optical Meters

    Gamma Scientific Inc.

    The Gamma Scientific range of light meters includes handheld and benchtop models.  Configuration options include a wide range of sensors and calibrations in units including:  Luminous Flux (lumens) or Radiant Flux (Watts),  Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr),  Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr),  or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.

  • Virtual Display Analyzer

    V-Series - RayClouds Photoelectric Technology Co.,Ltd.

    V-Series Virtual Display Analyzer is equipped with high pixel and high resolution detector and detection lens simulating human eye, cooperated with ProICM professional analysis software to analyze the optical characteristics of ARVR equipments. It can accurately detect optical parameters such as luminance, chrominance, contrast, MTF, FOV, image distortion, Cross Talk, ghosting, etc. of the image and quickly output the results of the measured parameters, providing a perfect product testing scheme to carry out strict quality control of ARVR products. ContactContact

  • Instrumented Runway Visual Range Transmissometer System

    AGIVIS 2000 - Aeronautical & General Instruments Ltd.

    AGIVIS 2000 is a transmissometer-based Runway Visual Range (RVR) system that provides the highest possible levels of accuracy. The first generation of AGI RVR systems were developed in co-operation with the UK Met Office and CAA, and AGI has been supplying RVR systems for more than 25 years. AGIVIS 2000 systems are currently operational at major international airports certified for instrument landings up to and including CAT IIIB. AGIVIS 2000 is fully compliant with ICAO, WMO and CAA requirements. The system consists of transmissometer field sites, background luminance meters, runway lighting interfaces, data processing equipment and archive storage and backup. It can drive multiple full-colour dedicated RVR displays. Systems can be supplied fully installed with comprehensive engineering and operator training, and post-installation support is available worldwide.

Get Help