product
AC/DC Linear Power Supply
Linear AC-DC power supplies are electronic devices used to convert electrical energy from alternating current (AC) to direct current (DC), providing a stable and regulated power supply for electronic devices. They are represented by the DA series.Linear power supplies of the DA series are characterised by their low output noise and high speed. They can be used as power amplifiers; a sinusoidal voltage of 8/10 Vpp can be superimposed on the test voltage up to a frequency of 50 kHz.Another application for this power supply family is the simulation of the curve of a photovoltaic panel by programming the voltage and current.
-
product
L Band Splitter, DC Block All Ports
PD5042
INSTOCK Wireless Components, Inc
Wideband Frequency (698 - 2700 MHz)Low Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)50 VDC maximum on DC block portsTri Alloy Type N Female (Jack) Low PIM
-
product
Digital Multimeter
189 DM
Standard Electric Works Co., Ltd
● 4000-count LCD.● Auto ranging.● Voltage, Resistance, Continuity, Diode measurement.● Frequency, Capacitance, Current measurement.● Wide range for capacitance test : 0~4000μF.● Data hold function.● Low battery indication.● Over range indication.● Auto power off.● With a convenient stand for viewing.● Compact and lightweight.
-
product
Waveguide Twists
Fairview Microwave’s precision waveguide twists operate from 18 to 110 GHz across seven frequency bands with waveguide sizes ranging from WR-42 (18 GHz) to WR-10 (110 GHz). Our portfolio of waveguide twists feature gold plated brass construction that offers excellent electrical performance with VSWR as low as 1.02:1 and insertion loss as low as 0.2 dB. Both 45° and 90° waveguide twists are available from stock, with the 45° versions being available in both right hand and left hand twist configurations. All of our waveguide twists are in-stock and ready to ship today!
-
product
Resonant Chopper Systems
Electro-Optical Products Corp.
An external clock signal, to provide an ultra stable modulating optical beam motion [sub] system. The system can be used as a "stand alone" unit, in the laboratory, or can be incorporated into a larger instrument/system. The chopper is ONE FIXED FREQUENCY, picked from the range of 5 Hz to 20 kHz. The chopper is a small size, light weigh, low cost and long life device. It requires low power drive electronics and does not radiate electromagnetic interference (EMI). It has high frequency stability and high amplitude stability. The chopper is IR, VIS and UV and high vacuum capable. Reference signal and position output available.
-
product
Single Phase Impulse Winding Tester 3 kV
SME1203
Scientific Mes-Technik Private Ltd
Single Phase , 3 kV Impulse winding testing Low inductance impulse test: down to 10 μH Low energy test without damaging the coil Fast detection of winding insulation at a speed of 5.5 Meas/sec 4 kinds of waveform comparison methods Up to 40 MSPS sampling rate 320×240 dot-matrix graphic LCD display Multi-trigger mode programmableVoltage, Time and Frequency measuring functions Direct display of comparison result
-
product
Bearings Vibration Meter
HG-2510
DETECTING VIBRATION INTENSITY OF EQUIPMENT Vibration Detection of Machinery Equipment Hitches of rotary machinery will result in abnormal vibtation. Increasing of low frequency vibration intensigy can be caused by unbalance of rotor, nonaxiality of rotating axis,looseness of base and iol membrane vibration of bearings.
-
product
500 MHz Passive Probe for WaveJet Touch, 10:1, 10 MOhm
PP006D
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Passive Probes
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
High Impedance Active Probes
28 AND 29
Designed to serve the needs of integrated circuit engineers working in the most advanced high speed, submicron, MOS technology. These high frequency instruments include the attractive features of the Models 18C and 19 including full dc capability, negligible dc current drain, and extremely low input capacitance. In addition the frequency range of the Models 28 and 29 has been extended to a full 1 GHz.
-
product
Counters & Frequency
NLS panel mount digital counters, frequency meters, and interval timers are available in four case sizes and feature a wide range of functions. These versatile, rugged, and low cost meters find many applications. Features in various meters include highly accurate crystal time base circuitry, counts of up to one million per second, frequencies to 60 MHz, battery back-up and a presettable decimal point. Multiplexed BCD outputs are also available for some meters.
-
product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
product
GPS Signal Splitter 12 Way, SMA Jack, 1 - 2 GHz, 50 Ohm Coaxial
GPS121
INSTOCK Wireless Components, Inc
Wideband Frequency (1000-2000 MHz)Low Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA Max on DC Block PortsTri Alloy SMA Female (Jack) Low PIM
-
product
Industrial Clamp Meters
*Measures AC+DC current*AC and AC+DC voltage measurements with digital low pass filter for accurate readings on variable frequency drives*Also measures DC voltage, resistance, capacitance and frequency*Tests continuity and diodes*Flashlight inside clamp jaw for easier work in dark locations*Backlight & relative mode for added versatility*Peak-RMS measures motor inrush current*AmpTip™ increases accuracy on small wires and low current*Two voltage detection modes - non-contact or using a single test lead*Data hold*Recording of Maximum, Minimum, and Average readings*Crest (peak hold) feature captures current or voltage peaks as short as 5 milliseconds
-
product
High Speed End Launch Connectors
Fairview Microwave’s high-speed end launch connectors are comprised of four models that provide VSWR as low as 1.10:1 and a maximum operating frequency of 40 to 110 GHz, depending on the model. These end launch connectors are reusable, don’t require any soldering and have a compact profile with a 0.350-inch mounting width and a 0.005-inch launch pin. They feature an outer conductor made of stainless steel and a gold-plated beryllium copper center contact.
-
product
PXI Dual 6 to 1 RF Multiplexer 6GHz 50 Ohm SMA Terminated
40-881-002
The 40-881 is a 50 Ohm 6 to 1 6GHz multiplexer available as a single or dual MUX in one and two PXI slots respectively. The 40-881 exhibits low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the 40-881 ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
product
Sound Level Meter
735
Whether you are testing for OSHA compliance, quieting equipment, or monitoring the roar of a stadium crowd, B&K Precision's Sound Level Meters can get the job done. The model 735 Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting.
-
product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
Computer-Based Instruments
GT668PXIe
GuideTech’s GT668PXIe PXI 3U form factor, meets industrial standard chassis with an expandable platform, achieving optimal test system at low cost. High accuracy 100MHz time base with NIST traceable calibration. Some of the GT668PXIe-1 measurements include Jitter measurements, PLL & Clock Jitter, Spread Spectrum Modulation, PLL Lock Time, Frequency, Period, Pulse Width, Skew, Tpd, Rise/Fall Time, Time Interval Error and more.
-
product
DC Blocking Power Splitter Combiner
PD5060
INSTOCK Wireless Components, Inc
Wideband Frequency (698 - 2700 MHz)Low Insertion Loss (0.5 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)50 VDC maximum on DC block portsTri Alloy Type N Female (Jack) 50 Ohm
-
product
Dual Polarized Scalar Feed Horn Antenna, 24 to 42 GHz, 15 dBi
SAF-2434231535-358-S1-280-DP
Model SAF-2434231535-358-S1-280-DP is a dual polarized, WR-28 scalar feed horn antenna assembly that coversseveral popular 5G bands in the frequency range of 24 to 42 GHz. The antenna features an integrated orthomode transducer (OMT) that provides high port isolation and cross-polarization cancellation and a broad band scalar horn that provides low side lobe levels.
-
product
PXI Dual 4 to 1 RF Multiplexer 6GHz 50 Ohm SMA Terminated
40-882-002
This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
product
Multibeam Profiler Sonar
MB2250-N/W
At 2.25 MHz, the MB2250 delivers 3D profile data at levels more akin to a laser line scanner than today's low frequency bathymentry systems. Mountable on Boats, ROVs, UUVs, and Tripods, BlueView's MB2250 is the right tool to take your operation into the next generation of 3D bottom and structure mapping.
-
product
PXI Triple Microwave SPDT Relay 26.5GHz 50 SMA
40-780A-533
This PXI microwave module is part of a range that gives you the highest RF & microwave switching performance available. Applications are mainly in the microwave region, however there are many uses in the RF spectrum where extremely low insertion loss and ultra high isolation are critical, they may also be used for lower frequency RF applications where power handling to 240W is required (700W for N-Type options).
-
product
T3AFG Series - Function / Arbitrary Waveform Generator
T3AFG Series
Teledyne Test Tools new T3AFG series of function / arbitrary waveform generators use advanced Digital Frequency Synthesis (DDS) technology to produce high quality standard function and arbitrary waveform signals. They also provide a wide range of analog and digital modulation functions. The T3AFG series of Arbitrary Waveform Generators includes models with up to 120 MHz bandwidth, 1.2 GSa/s sample rate, 16-bit vertical resolution and 8 Mpts of data. Common analog and digital modulations, sweep a...show more -
product
Noise Source, 10 MHz to 18 GHz, nominal ENR 15 dB
346B
The Keysight 346B noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 18 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. The 346B's high ENR, low SWR, and variety of connectors make it a general-purpose noise source. Add special option H01 for high ENR (21 dB typical) to measure high noise figure devices, or option H42 for measuring Direct Broadcast Satellite (DBS) low noise block converters.
-
product
PXI 4 x Changeover Switch 1GHz, 75 SMB
40-710-754
Model 40-710 RF switching card has a bank of 4 individual high performance RF changeover switches (50 or 75 Ohm, Bi-directional) with very low insertion loss, suitable for handling signals up to 2.5GHz. Applications include aerial switching, routing high frequency signals into oscilloscopes and analysers.Available with a choice of connectors: SMA, SMB and Siemens 1.0/2.3 versions. BNC versions are also available with reduced bandwidth and 2 PXI slot occupancy.
-
product
47~2600MHz Satellite TV & Digital TV 1550nm Externally Modulated Optical Transmitter
HES-26D
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HES-26D series 1550nm external modulation optical transmitter can transmit 47~2600MHz analogue signal and digital signal via one single fiber by frequency division multiplexing. It is compatible with any FTTx PON technology, and provides a complete set of high quality low cost fiber trunk transmission and fiber to the building (FTTB), fiber to the house (FTTH) solution for the direct broadcast satellite TV (DBS) and cable analogue TV (CATV) fusion.
-
product
Passive Probe
PP011-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more