Showing results: 616 - 630 of 728 items found.
-
MicroLogPLUS -
Fourier Systems
A wireless data logging system for remote monitoring of up to 200 data loggers via the cradle technology and transmitting all real-time measurements to the PC. Handles data from up to 200 MicroLogs at up to a distance of 300m (120m US Version). Two open collector output for controlling other devices set at low and high alarm levels
-
KOSHAVA-AT -
Wuntronic GmbH
The independently operating Tesla Meter / Gauss Meter Type KOSHAVA analog for connection to a digital multimeter, oscilloscope, data logger or data acquisition card is an inexpensive alternative to the handheld and USB Tesla meter / Gauss meters.
-
KOSHAVA-AA -
Wuntronic GmbH
The independently operating Tesla Meter / Gauss Meter Type KOSHAVA analog for connection to a digital multimeter, oscilloscope, data logger or data acquisition card is an inexpensive alternative to the handheld and USB Tesla meter / Gauss meters.
-
TQSoft and TQAero -
Fluke Calibration
Thermal validation from TQSolutions has long supported the Fluke Hydra Series data loggers. TQSoft and TQAero now support the Fluke 2658A Hydra Series III and 1586A Super-DAQ Precision Temperature Scanner for enhanced data collection and reporting required in regulated industries. It's deal for applications requiring compliance to FDA 21 CFR Part 11 and AMS 2750.
-
EL-USB-CO -
Lascar Electronics Ltd
The EL-USB-CO is a USB data logger that measures and stores up to 32,510 Carbon Monoxide (CO) readings over a 0 to 1000 ppm measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PC's USB port and running the purpose designed software under Windows 2000, XP or Vista
-
VRS-20 -
Valeport Ltd,
Versatile and simple to install, the VRS-20 has been developed by Valeport to work seamlessly with the TideMaster Tide Display/Logger and other third party data loggers using RS232, RS485 and SDI-12 communication. Non-contact technology removes the installation, corrosion & fouling issues of submerged sensors, while simplifying datum control. Accuracy and performance are unaffected by changes in water density and atmospheric conditions.
-
ACSRF-4040 -
Gemini Data Loggers Ltd.
The Plus Radio Ethernet receiver is required as part of the Tinytag Radio Data Logging System. It controls the transmission of data to and from the radio loggers: data received from the loggers is then sent to the computer for viewing with Tinytag Explorer radio software. If power to the computer running the system is lost, the receiver has a battery back-up which will maintain the mesh network until power is restored. This receiver plugs directly into a LAN removing the need for a computer in the area where monitoring is to take place. The receiver is powered using a plug-in Power over Ethernet adaptor (ACS-0041) which is supplied with the unit.
-
ILA -
Dwyer Instruments Inc.
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
LA-Gold-16 -
TEAM SOLUTIONS, INC.
A maximum sampling rate of 1 GHz is available on all channels. The LA-Gold-16 has a large data buffer of 1 Mega samples per channel for sampling rates of up to 500 MHz on all 16 channels. The large buffer allows long capture times at high sampling rates. The digital logger function is for capturing very slow varying signals, e.g. room temperature.
-
Sper Scientific
pH measures the acidity/alkalinity of a solution on a scale of 1 to 14 pH, with 1 being the most acidic and 14 being the most alkaline or basic. pH is a common measure of water quality used in environmental testing, food & beverages, cosmetics, pharmaceuticals and other fields. Four basic styles of pH meters are available for varying applications: Pens, Portable Meters, Data Loggers, and Benchtop meters.
-
MINITAUR-S -
Dewesoft d.o.o.
Mixed signal 8-channel data acquisition system and multichannel data logger with cutting-edge technology at an attractive price. Universal analog inputs can accommodate various signals like strain gage, IEPE, voltage, current, RTD, thermocouple, and LVDT.
-
ComTekk Engineering, LLC.
CTCSS sub-audible tone decoder reveals repeater access tones DCS Digital-Coded Squelch decoding (requires receiver with discriminator or demodulator (unfiltered) output) DTMF "Touch-Tone™" decoder / logger Improved 2-tone decoding captures "stacked" pages Built-in Log Viewer / Player External serial port control to operate relay or PTT circuit Fully supports Windows XP, Vista / 7, 8, 10
-
CHY firemate Co., Ltd.
Save data: 128 samples with real-time data.Data logger: 16 sets, Maximum 1024 data capacity.Easy Reads Data with down and up key on meter.T/C Offset Adjust.REC, MAX, MIN, MAX-MIN, AVG, REL, HOLD functions.T1, T2, T1-T2, Time and Memory No.Resolution 0.1°C/1°C, 0.1°F/1°F.Warning beeper with Hi/Lo setting.Real time clock with calendar.Selectable Auto Power Off function.
-
General Tools & Instruments
Together, an environment's temperature and relative humidity (RH) indicate how comfortable it "feels" to humans. General sells a variety of temperature/humidity monitors that either show real-time readings like the A600FC High Temperature Analog Humidity-Temperature Meter or log measurements over time for trending purposes such as the HT50 USB Temperature-Humidity Data Logger. Trend analysis is the rationale for another popular application for temperature/RH monitors - water damage restoration.
-
U2652A -
Keysight Technologies
The Keysight U2652A USB Digital I/O is a cost-effective device with its offering of 64 opto-isolated digital lines. It comes bundled with the Keysight Measurement Manager (AMM) software for quick set up and data logging. Simplifying this further is the command logger function offered in the Keysight Measurement Manager that allows capturing of configuration commands that can be easily converted to snippets of VEE code. Other supported languages are VB, C++, and C#.