Showing results: 1291 - 1305 of 2327 items found.
-
Coaxial Dynamics
Coaxial Dynamics "Standard" line of RF Power Sensors provide DC currents proportional to the forward and reflected power flowing through the line. All models are designed to drive a 30A, 1400-Ohm meter, or provide approximately 100 millivolts across a 5K load.
-
Bank Elektronik
Current sinks are electronic circuits which can sink electric power in a controlled manner, thus acting as controlled loads. Our current sinks are designed as four - quadrant current sinks which can feed and sink currents in both polarities (also disregarding the polarity of the resulting voltage).
-
DAA -
North Atlantic Industries
NAI’s DAA is an AC-Powered, Voltage Monitor used to continuously measure voltage on three-phase Delta power lines. This allows normal operation of system loads when the voltage characteristics are within pre-determined limits. The DAA voltage monitor is ideally suited for rugged defense and industrial applications.
-
480 -
Interface Inc.
Large 0.8 in LED 6-digit Display• 100,000 displayed graduations• 523,000 internal counts• Powers up to 10 Load Cells• Tension/Compression operation• NEMA 4X stainless steel enclosure• Measurement Rate up to 40Hz• Selectable filter settings• 0.1uV/graduation signal sensitivity
-
LDF Series -
Bemco Inc.
The Bemco LDF Series of wide range expendable refrigerant chambers are designed for low initial cost, rapid temperature cycling, environmental stress screening (ESS), and for handling large thermal loads. These systems are compact for their size, can be bench mounted, and are easily modified to special testing configurations.
-
Dotcom-Monitor
Establish response time baselines under specific user load numbersIdentify performance bottlenecks as the number of simultaneous users increasesFind upper limits of current systems to plan for future capacity (Capacity Planning)Stress your production environment to see how and when things fail
-
INS Series -
Noise Laboratory Co.,Ltd.
A simulator to reproduce fast rise-up noises which are generated when switching ON / OFF electric current on the inductive load. It can be used for performance evaluation of electronic equipment upon reproduction of line noises which are intruded to the power supply lines or induced noises onto the telecommunication lines.
-
GX6315 Series -
Marvin Test Solutions, Inc.
The GX6315 is a 45 channel, high current relay board that plugs directly into any 6U PXI slot. The GX6315 also provides nine transistor-driven channels for external relays. These outputs may be used to drive external loads, such as heavy duty relays, lamps or other devices.
-
GX6115 -
Marvin Test Solutions, Inc.
The GX6115 is a 15 channel, high current relay board that plugs directly into any 3U PXI slot. The GX6115 also provides three transistor-driven channels for external relays. These outputs may be used to drive external loads, such as heavy duty relays, lamps or other devices.
-
909A -
Keysight Technologies
The Keysight 909A is a general-purpose, low-reflection load for terminating a 50-ohm coaxial system in its characteristic impedance over the dc to 18 GHz range. It is suitable for both broadband and narrowband measuring instruments. The Keysight 909A may be ordered with an APC-7, type-N female, or type-N male connector.
-
Synectic Electronics
The SY008 VI Load Cell Sensor Signal Conditioner IP66 converts 0-5V dc in to 4-20mA out. The SY008 can either provide a 5V or 10V source to a variety of transducers; load cells, RVDTs, potentiometers (precision linear transducer), tilt sensors and contactless position sensors. Almost any sensor that produces an output signal voltage in the range 0-5V dc.
-
MaxLinear
The XRP6124 is a non synchronous step down (buck) controller for up to 5A point of loads. A wide 3V to 30V input voltage range allows for single supply operations from industry standard 3.3V, 5V, 12V and 24V power rails. With a proprietary Constant On-Time (COT) control scheme, the XRP6124 provides extremely fast line and load transient response while the operating frequency remains nearly constant. It requires no loop compensation hence simplifying circuit implementation and reducing overall component count. The XRP6124 also implements an emulated ESR circuitry allowing usage of ceramic output capacitors and insuring stable operations without the use of extra external components.
-
Osborne Transformer Corp.
Osborne Saturable Reactors are designed to provide a variable output voltage through the use of variable impedance connected in series with a constant impedance load. Each saturable reactor’s impedance is determined by the application of DC power to a control winding. As the level of power supplied to the control winding is increased, the saturable reactor becomes more saturated. This reduces the impedance of the AC gate winding, and increase the amount of the supply voltage that is transferred to the load. Conversely, as the power is reduced to the control winding, the reactor becomes less saturated, the gate winding has more impedance and less of the input voltage is provided to the output impedance. This approach provides excellent quality, reliability, and control when designed to match the requirements of a specific application.
-
1006 -
Pavone Sistemi S.r.l.
The Tester 1006 has a simultaneous control function of up to 4 load cells in any weighing system, upload and download function for programming the DAT and MC 302 series instruments, but it can also be used as a Calibrator and Peak detector. It is very useful for the correct mechanical installation and for fault diagnosis. The Tester 1006 is supplied as standard with cable for connection to our junction boxes / sum mod. CEM 4 / C and CGS 4 / C. Simultaneous display of the signal of each individual load cell allows to control the entire weighing system, weight distribution, overloads, faulty cells and faulty connections. OUT OF PRODUCTION. Pavone systems provides a new version of Tester 1006: Tester 1008.
-
ERAVANT
A measurement device that is inserted into the transmission line between an RF source—such as a signal generator, vector network analyzer, or transmitter—and a load.