Filter Results By:

Products

Applications

Manufacturers

Loads

test full state.

See Also: Load Boards


Showing results: 1216 - 1230 of 2322 items found.

  • DCDC

    HA/HP Series - Semiconductor Circuits, Inc.

    The HA/HP series features the latest in MOSFET design, state of the art surface mount technology, and offers a 4:1 ultra-wide input range, and efficiencies greater than 75% (typ). Features include Pi input filter to reduce input reflected ripple, continuous short circuit protection, and excellent line and load regulation of ±0.25% for line and ±1.0% load. Additional standard features include, 500 Vdc I/O isolation, and an operating temperature range of -25°C to +71°C with no derating. All models are packaged in a six-sided shielded miniature case measuring only 2.0” x 2.0” x 0.375” high.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2205 - TREK, INC.

    The Trek Model 2205 is a member of Trek’s 2200-series of high-voltage 40 W amplifiers that offesr high performance at an attractive price. It incorporates DC stability, wide bandwidth, well regulated and controlled AC output signals, full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument also stage sinks or sources current into reactive or resistive loads throughout the output voltage range which makes it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • Bench Power Supply, Calibrated, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A

    72-2690 CAL - Tenma

    The 72-2690 CAL from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).

  • Basic Heating Module

    QWED Sp. z o.o.

    Microwave heating analysis including loads rotation and translation, frequency tuning, heat flow and material parameters modification as a function of dissipated power. QW-BHM (Basic Heating Module) for QuickWave 3D provides a novel regime of operating the FDTD solver: the possibility of simulating microwave heating problems.The software has been prepared to work in sophisticated regimes, modelling rotation and movement of the heated load(s) even along complicated trajectories, etc. Transfer of the heat generated by electromagnetic fields can be modelled with external or internal Heat Transfer Module or by coupling QuickWave 3D simulations to external computational fluid dynamics packages.

  • Avionics Data Loaders

    Astronics Corporation

    The Ballard DL 615 Data Loader is the modern replacement for outmoded 3½-inch floppy-disk-only ARINC 615 portable data loaders (PDL). Any PC running Microsoft® Windows® can perform data loads using the USB to ARINC 429 interface, cables, and software included with the DL 615. While being as simple to use as older floppy disk PDLs, the DL 615 provides record keeping, flexibility in data management, and powerful features for troubleshooting and enabling data loads into difficult LRUs. As an added benefit, the interface can be used as a general purpose ARINC 429 (and optionally ARINC 717) maintenance tool.

  • Strip Tension Measurement

    ABB Ltd.

    ABB’s strip tension system is the perfect choice for measuring strip tension in hot rolling, cold rolling and process lines.Accurate strip tension measurement is a prerequisite for keeping the strip tension constant within the desired range, during both acceleration and deceleration. This allows for optimal strip quality, increasing process uptime and preventing strip breaks. The system is proven to be exceptionally robust and resilient to high forces as well as aggressive mill agents. The load cells are calibration free, can withstand overloads up to 10 times the nominal force, and have an impressive life length. The load cells come in different sizes up to 200 kN.

  • SparkFun Qwiic Scale

    NAU7802 - SparkFun Electronics

    The SparkFun Qwiic Scale is a small breakout board for the NAU7802 that allows you to easily read load cells to accurately measure the weight of an object. By connecting the board to your microcontroller you will be able to read the changes in the resistance of a load cell and, with some calibration, you'll be able to get very accurate weight measurements. This can be handy for creating your own industrial scale, process control or simple presence detection. Utilizing our handy Qwiic system, no soldering is required to connect it to the rest of your system. However, we still have broken out 0.1"-spaced pins in case you prefer to use a breadboard.

  • L.V. Power Capacitors

    Entes Elektronik

    LV power capacitors are circuit elements which compensate the inductive reactive loads on a system. Being able to connect and disconnect up to 100 times a day in accordance with load variations in automatic reactive power compensation systems really speaks for the quality and endurance and capacitors. Upon connection/disconnection instances, currents which have higher values than the nominal value may occur on reactive power compensation capacitors. ENTES ENT.C series power capacitors are designed to withstand the severe and poor conditions which may shorten the operating life during reactive power compensation. This endurance is the result of advanced engineering and long-term test procedures.

  • Portable Electricity Meter Testers

    EE-120A-3S + EE-500V-3 - EMSYST Ltd

    The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.

  • Current Transformer

    LTTJ - Dwyer Instruments Inc.

    Love Controls LTTJ Series Current Transformers allow easy monitoring of the current flowing to your load. This easy to use device provides a 0 to 10 VDC signal into both low and high impedance circuits, and is easily scalable to your needs

  • Electricity Metering Device

    Mk7A - EDMI Ltd.

    Built on the advanced Atlas metering platform, the Mk7A is a single phase 2-element meter which integrates both a 100A UC3 compliant relay and 40A UC2 compliant load control relay which allows disconnection and reconnection of electrical services remotely.

  • Fanout Buffers

    Analog Devices Inc.

    Fanout Buffers are able to create multiple copies of input signal at their output and distribute them amaong several loads while achieving fast rise/fall time and low jitter. Input and output interfaces are CML and output voltage swing can be adjusted externally.

  • High Accuracy 100 Amp Current Probe

    HA100 - Summit Technology, Inc.

    The HA100 is a compact clamp-on current probe for smaller loads where compact size is important.  Its measurement range is from 0.1 to 100 amps AC and is very small which is ideal for locking inside a crowded electrical panel during monitoring.

  • High-Power Directional RF Wattmeters

    81100-A Series - Coaxial Dynamics

    The 81100-A series of High-Power Directional RF Wattmeters are designed to measure RF power in 50-Ohm 1-5/8 inch coaxial transmission lines. To use the Wattmeter, simply connect it between the transmitter and antenna or dummy load and plug in the appropriate measuring element.

  • Moisture-in-oil Monitor

    doblePRIME DOMINO - Doble Engineering

    The doblePRIME DOMINO provides real time data for moisture in oil, giving indications of relative saturation or absolute ppm levels. This is useful information, especially when a transformer is being loaded in excess of nameplate or when the transformer is undergoing abnormal load cycles.

Get Help