Filter Results By:

Products

Applications

Manufacturers

Loads

test full state.

See Also: Load Boards


Showing results: 2101 - 2115 of 2342 items found.

  • Solar Panel Large Walk-in Chambers

    EWSX282 - ESPEC North America, INC.

    ESPEC's solid construction walk-ins are desirable for testing large loads of PV modules or panels at 85°C/85% as well as humidity-freeze and temperature cycling tests. Hermetically welded seams and stainless-steel interior ensure integrity under extreme conditions required by IEC.The models come in different performance versions, depending on your application. More powerful performance allows you to complete the temperature-cycling test faster, or with a maximum number of modules. There also is a 'damp-heat' only model that saves you capital-cost and energy.

  • 1-phase Power Analyzers

    PeakTech Prüf- und Messtechnik GmbH

    Is a high-precision energy cost measuring device for recording the energy consumption of electrical devices and for calculating the current consumption of a device by entering the electricity price. Thanks to the integrated power factor calculation, all modern consumers such as Switching power supplies, TV sets, fluorescent lamps, LED systems and of course ohmic loads such as Electric heaters and hobs can be measured accurately. In addition, the high resolution, the low response characteristic and even very small or stand-by consumers from approx. 1 W can be measured.

  • Transformer Winding Resistance Meters

    TWA Standard Series - Amperis sl

    The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.

  • 4.0 GHz, 0.6 pF, 1 MOhm Active Voltage Probe

    ZS4000 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.6 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.

  • 2.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe

    ZS2500 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS2500 is ideal for 2.5 GHz and lower oscilloscopes.

  • 1.5 GHz, 1 MΩ, 0.9 pF Active Probe

    ZS1500 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1500 is ideal for 1 GHz and lower oscilloscopes.

  • 1 GHz, 1 MΩ, 0.9 pF Active Probe

    ZS1000 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes.

  • Battery Monitoring System

    BMS-3923 - Kongter Test & Measurement Co., Limited

    This battery monitoring system is an innovative solution to measure battery condition with communication way of Power Line Carrier (PLC). With multi-frequency measurement, users can monitor and analyze battery in all aspects: internal resistance, voltage, current, capacitance, temperature and so on.Based on our years experience for battery management system, we build very mature mathematical model that precisely predicts battery capacity. This will in another hand reduce the time that we spend on capacity measurement using a battery load bank.

  • 4-CH 24-Bit Universal Input USB DAQ Modules (OEM Version Available)

    USB-2401 - ADLINK Technology Inc.

    The USB-2401 is a 24-bit, 4-channel simultaneous-sampling universal input USB DAQ modules featuring built-in signal conditioning circuitry, providing direct measurement of commonly used sensors including current output transducers, thermocouple, RTD, load cell, strain gauge, and others. Individual channels can be programmed to measure different signal types. The USB-powered USB-2401 is equipped with removable screw-down terminals for easy device connectivity, and the included multi-functional stand fully supports desktop, rail, or wall mounting.

  • IGBT Power Supplies - Air Cooled

    Carl E. Holmes Company

    CEHCO The MSA1000 Rectifiers are based on IGBT Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%. The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.

  • Switch Mode Power Supplies-Water Cooled

    Carl E. Holmes Company

    The MSW Rectifiers are based on Switch Mode Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%.The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.

  • High Capacity, Mechanically Refrigerated Temperature Chambers

    FHC Series - Bemco Inc.

    The Bemco FHC Series of high capacity, mechanically refrigerated temperature chambers are designed for rapid temperature cycling, environmental stress screening (ESS), and for handling large thermal loads. Available in both Wide Range, (-73 C to 177 C or -100 F to +350 F) and Narrow Range (-35 C to + 177 C or -31 F to + 350 F) these systems include very large, efficient, and modern cooling and heating systems to allow rapid temperature transitions.

  • 8Ch Speaker/Receiver Unit Tester

    BK9012 - BaKo Co., Ltd

    Based on the BK2120A Audio Analyzer, the BK9012 is designed to quickly test microspeakers or receivers 4~8 at a time at a rate that you’ll find hard to keep up with. It tests various frequency characteristics and also rub & buzz so you know the quality of your product is maintained. And of course, you can track the accuracy and stability of your process using the data you’ve saved on about 4 million microspeakers (based on a 6 second total test + load time) per month.

  • Cable Electric Resistance Tester

    MR 270 C-A - Schuetz Messtechnik GmbH

    The MR270C-A is specially designed for electric resistance measurements in cable industry applications and inductive loads (transformers, motors). It is perfectly fit both for measuring the meter resistance in connection with a corresponding resistance measurement holding device or for final acceptance control of power cable reels. In the case of cable reels, which often have a cable length of several kilometers, both the compensation of the inductive component and the ability to perform measurements in the presence of high noise levels are important. This also applies to the winding resistance of transformers and motors.

  • Precision Metal Clad Shunt Resistor

    IRHF - RARA Electronics Corporation

    Precision Metal Clad Resistors designed in four- terminal technique, are distinguished by high load capacity as well as excellent accuracy. Isolated voltage and current connections making them suitable for very precise current measurements. Easy current measurement is performed by attaching to current bus directly and connecting to voltage (ampere) metal through flexible wires. The ULH models are UL approved versions. Units have a low inductance, heavy copper terminals. The main application is battery manufacturing test jig.

Get Help