  • Test Bench for Starters and Alternators

    MS002 COM - MSG Equipment

    A high power multifunctional test bench includes the following diagnostic functions: diagnostics of starters, alternators and voltage regulators without applying any additional measuring devices. The test bench was invented on the basis of the requirements of modern service stations: construction implies mounting of majority of units without using additional fixing elements. The bench tests units of 12V and 24V; diagnoses the latest alternators and voltage regulators, which are controlled by car ECU; has ports to connect alternators of different brands and manufacturers: COM (LIN, BSS), P-D, DFM, D+, RLO, C, SIG. Diagnostics is carried out through load simulation of car consumers, change of rotation speed, sending of control signals (external control alternators), tracking of electrical characteristic. Testing results are transmitted to LCD display real-time. Testing modes are switched with membrane keyboard on the control panel of the test bench. The selected mode is lightened with the corresponding indicator.The equipment carries out testing of different alternators under load up to 200A. Power supply is single-phase 380V.

  • PXI Strain/Bridge Input Module

    NI

    PXI Strain/Bridge Input Modules feature up to eightchannels that support quarter-, half-, or full-bridge sensors at speeds up to 102.4kS/s. The modules provide increased accuracy, high data throughput, and a range of synchronization features. Optional features include remote sensing, internal bridge completion, and shunt calibration options per channel. PXI Strain/Bridge Input Modules are ideal for dynamic strain, load and pressure measurements, and test cell installations requiring accuracy and flexibility.

  • Power Functional Test with Energy Saving Solutions

    Power System - SEICA SpA

    The Power System is a test platform conceived to verify and certify the operation of power modules.The complete structure, combining two Multi standard cabinets, is sized to contain all of the resources required for testing: drive/sense modules, power modules and load simulators.In this tester, in addition to strictly perform the requested measurement as per technical specifications, the issues of consumptions and dissipations were taken into account, integrating an Energy Recovery circuit which enables reuse of output energy to supply the system.

  • Mini-Test Station

    Fuel Cell Technologies, Inc

    Mini-Test Station for low current fuel cell testing. The test station includes Analog mass flow controllers for Anode and Cathode gas streams, humidity bottles with preheaters and temperature controllers and a cell temperature controller. The test station is designed to use the customer's Potentiostat to load the cell. Manual backpressure is provided for pressures from 0-60 psig. The Mini-Test station is basically our Analog Mass Flow Controlled Low Flow Humidification System with all the options.

  • FC Impedance Meters

    Kikusui Electronics Corp.

    designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.

  • Shunt Voltage References

    Analog Devices Inc.

    Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.

  • Bench top Dielectric Withstand tester

    HYPOT III - Wavecontrol, S.L.

    RS-232 Interface available for automated controlPatented SmartGFI® functionPatented CAL-ALERT® functionComes complete with a test box for products terminated in a line cordPatented VERI-CHEK® functionStorage of up to 10 setups with 3 steps per setupBuilt-in security settingsDigitally controlled arc detection systemNo load setup of trip current and output voltageElectronic ramping (up & down)Built-in adjustable continuity testInterconnection to HYAMP® III to form complete test system

  • PulseTech Battery Analyzer, 6V and 12V Battery Tester

    390PT - PulseTech Products Corp.

    The 390PT Battery and System Tester lets you quickly, safely and accurately test both 6-Volt and 12-Volt lead-acid flooded, AGM (flat and spiral plate) and gel cell batteries in or out of the vehicle and test 12-Volt and 24-Volt charging systems for proper operation. Combined singe load, dynamic resistance technology and algorithms display battery voltage and capacity in easy to understand results in seconds. The handy "QUICK START" instruction guide is printed on the back of the tester.

  • Universal PMICs

    MaxLinear

    PowerArchitect™ design and configuration software speeds development and significantly reduces overall time-to-market compared to legacy analog power solutions. An I²C interface and multiple GPIO pins ensure easy system integration. Configurable warning and fault levels, fault behavior and power up and down sequencing ensure any load can be properly powered and protected. The power system design can be completed with confidence long before the final revision of the SoC or ASIC is available.

  • Visual Analysis of any Embedded System

    SystemView - SEGGER Microcontroller GmbH & Co. KG

    SEGGER is announcing the release of SystemView, a free tool enabling the visual analysis of any embedded system. SystemView gives complete insight into the behavior of a program, with minimal side effects on the observed embedded system. SystemView offers cycle accurate tracing of interrupts and task start stop as well as task activation and API calls when an RTOS is used. It visualizes and analyzes CPU load by task and interrupts and scheduler. Test setups with LED and oscilloscope are a thing of the past.

  • Modular Redundant Power Supply Systems

    Acopian Technical Company

    Extremely high overall reliability results from connecting two power sources so that one will continue to provide power to their load even if the other becomes inoperative. Redundancy may be restored by replacing or repairing the inoperative source while the system remains in operation. A redundant power system should be used whenever the highest attainable reliability is essential, as in communications, computer systems (data storage in particular), process controls, utility and municipal systems, and security/safety systems.

  • SLSC and CRIO Modules and Accessories

    Bloomy Controls, Inc.

    Our approach to delivering a high-quality Aerospace, Automated Test Equipment (ATE) asset begins with leveraging National Instruments hardware and software standard platforms. Beginning with high quality instrument platforms for standard Input and Output (I/O), we leverage NI’s PXI and Compact RIO platforms. Extending these system is NI’s unique platform for Switching, Loads and Signal Conditioning (SLSC), which allow the standard I/O to be customized for high performance aerospace industry applications.

  • AC Power Supplies

    BLC Series - Behlman Electronics Inc.

    The BLC Series delivers all the quality features our customers have come to expect from Behlman; clean sine wave output with excellent line and load regulation, high efficiency and low harmonic distortion. A multi-pulse input transformer offers low-input harmonic distortion and high power factor as required by European standards. Unique protection circuitry provides for over-temperature protection; short-circuit protection and voltage fold-back during overloads to maintain undistorted waveforms.

  • Signa; Generator

    MAG-203AD - MCH Instruments Co.,Ltd.

    Features:*Signal frequency:0 .1Hz-2Mhz, continuously variable*Wave form: square,sine*Output attenuator:0dB, 20dB, 40dB,60dB*Output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*Rising and falling edge of square not more than 35ns*Sine distortion less than 1%,amplitude -frequency characterstic:±0.3dB within 100khz, ±1dB above 1Mhz*Frequency meter: 10Hz-30Mhz*Power supply : AC 220V

  • Signal Generator

    MAG-2015AD - MCH Instruments Co.,Ltd.

    Feature:*Signal frequency: 0.1Hz~15MHz, continued*Wave form: square,sine*Output attenuator: 0dB,20dB,40dB,60dB*Output level: 20Vp-p in open ciruit,not less than 10Vp-p with 50Ω load*Rising edge of Square not more than 35ns at 2MHz*Sine distortion less than 1%,amplitude-frequency characteristic ±0.5dB with in 2MHz, ±3dB above 10MHz*Frequency Counter: 20Hz~30MHz*Power supply: AC 220v (110v optional)