Showing results: 2026 - 2040 of 2290 items found.
-
40-131-001 -
Pickering Interfaces Ltd.
These low cost, general purpose electromechanical relay cards are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 pin D-Type connector plug.
-
CAA-100 -
ShinewayTech
ShinewayTech® CAA-100 cable & antenna analyzer can test Return Loss and VSWR of load’ frequency. Also can get Return Loss, VSWR of DTF (distance-to-fault) and Cable Loss. Users can be easy to know the connection of cable & antenna system is reliable whether or not. CAA-100 series with frequency range 25MHz-4GHz and 60dB dynamic range can suitable for 2G/3G/4G/WiMAX system etc. CAA-100 series is the necessary measuring instrument for the new generation of wireless network development, upgrade and maintenance.
-
EWSX282 -
ESPEC North America, INC.
ESPEC's solid construction walk-ins are desirable for testing large loads of PV modules or panels at 85°C/85% as well as humidity-freeze and temperature cycling tests. Hermetically welded seams and stainless-steel interior ensure integrity under extreme conditions required by IEC.The models come in different performance versions, depending on your application. More powerful performance allows you to complete the temperature-cycling test faster, or with a maximum number of modules. There also is a 'damp-heat' only model that saves you capital-cost and energy.
-
PeakTech Prüf- und Messtechnik GmbH
Is a high-precision energy cost measuring device for recording the energy consumption of electrical devices and for calculating the current consumption of a device by entering the electricity price. Thanks to the integrated power factor calculation, all modern consumers such as Switching power supplies, TV sets, fluorescent lamps, LED systems and of course ohmic loads such as Electric heaters and hobs can be measured accurately. In addition, the high resolution, the low response characteristic and even very small or stand-by consumers from approx. 1 W can be measured.
-
TWA Standard Series -
Amperis sl
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
ZS4000 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.6 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.
-
ZS2500 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS2500 is ideal for 2.5 GHz and lower oscilloscopes.
-
ZS1500 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1500 is ideal for 1 GHz and lower oscilloscopes.
-
ZS1000 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes.
-
BMS-3923 -
Kongter Test & Measurement Co., Limited
This battery monitoring system is an innovative solution to measure battery condition with communication way of Power Line Carrier (PLC). With multi-frequency measurement, users can monitor and analyze battery in all aspects: internal resistance, voltage, current, capacitance, temperature and so on.Based on our years experience for battery management system, we build very mature mathematical model that precisely predicts battery capacity. This will in another hand reduce the time that we spend on capacity measurement using a battery load bank.
-
USB-2401 -
ADLINK Technology Inc.
The USB-2401 is a 24-bit, 4-channel simultaneous-sampling universal input USB DAQ modules featuring built-in signal conditioning circuitry, providing direct measurement of commonly used sensors including current output transducers, thermocouple, RTD, load cell, strain gauge, and others. Individual channels can be programmed to measure different signal types. The USB-powered USB-2401 is equipped with removable screw-down terminals for easy device connectivity, and the included multi-functional stand fully supports desktop, rail, or wall mounting.
-
Carl E. Holmes Company
CEHCO The MSA1000 Rectifiers are based on IGBT Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%. The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.
-
Carl E. Holmes Company
The MSW Rectifiers are based on Switch Mode Technology. This reliable technology assures excellent quality DC currents with a ripple of < 3% and a control accuracy of less than 1%.The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.
-
FHC Series -
Bemco Inc.
The Bemco FHC Series of high capacity, mechanically refrigerated temperature chambers are designed for rapid temperature cycling, environmental stress screening (ESS), and for handling large thermal loads. Available in both Wide Range, (-73 C to 177 C or -100 F to +350 F) and Narrow Range (-35 C to + 177 C or -31 F to + 350 F) these systems include very large, efficient, and modern cooling and heating systems to allow rapid temperature transitions.
-
BK9012 -
BaKo Co., Ltd
Based on the BK2120A Audio Analyzer, the BK9012 is designed to quickly test microspeakers or receivers 4~8 at a time at a rate that you’ll find hard to keep up with. It tests various frequency characteristics and also rub & buzz so you know the quality of your product is maintained. And of course, you can track the accuracy and stability of your process using the data you’ve saved on about 4 million microspeakers (based on a 6 second total test + load time) per month.