Showing results: 511 - 525 of 3752 items found.
-
1227 -
Dwyer Instruments Inc.
Use Series 1227 as a regular U-tube manometer to read high-range pressure on the right leg, or as an inclined manometer to read low-range pressure on the bottom leg. Simply incline manometer until fluid levels read zero. No spirit level required
-
LEVELUPS SERIES 10 - 200 kVA -
Makelsan Power Systems
LevelUps T3 Series is a true VFI on-line double conversion, three-phase UPS system with Innovative 3 Level Technology and engineered to provide high level of energy efficiency and reliable and robust protection for most demanding industrial and medical environments.
-
Guangzhou Amittari Instruments Co.Ltd
The Sound Level Meter is divided into two types: ( AS-156A Accuracy : ±2dB), (AS-156B Accuracy : ±1dB ). Can memorize 30 groups of measurement results and measuring conditions. Permits choice “A” / “C” / “F” weighting and “Fast” / “Slow” response times. Offers 4 measurement parameters: Lp ( soundlevel). Leq (Equivalent Continuous A Sound Level). Lmax (Maximum Sound Level) and LN (Percent of all readings over alarm value set).
-
Eckel Noise Control Technologies
Anechoic Chambers are echo-free enclosures with a sound energy absorption level of 99% to 100%, or a reflected sound pressure level of 10% or less. The frequency at which the energy absorption drops below 99%, or the pressure reflection exceeds 10%, is known as the low-frequency cut-off. Sound absorption is obtained by lining the walls, ceilings, and floor with wedges or other sound absorbing elements or SuperSoft panels, depending on performance level required and cut-off desired.
-
ERAVANT
Delivers a 3 dB nominal coupling level and 25 dB nominal directivity across the full waveguide band from 110 to 170 GHz. The three-port coupler uses a traditional multi-hole and split block design to achieve a flat coupling level, high directivity, and low insertion loss. The interfaces of the coupler are WR-06 waveguides with UG-387/U-M flanges. Other coupling levels are available under different model numbers.
-
ENVIROMUX-GD-MBP -
Network Technologies Inc
Use to detect leaks of combustible gas (methane, propane, butane, acetylene, etc.). Choose between two levels of detection. First level: Detects methane at concentrations in excess of 0.5%; Detects propane/iso-butane at concentrations in excess of 0.3%. Second level: Detects methane at concentrations in excess of 0.8%; Detects propane/iso-butane at concentrations in excess of 0.5%. Continuous air monitoring. Audible alarm signal: 94 dB at 1 foot. Relay specifications: level selectable, normally open or normally closed, 250V AC, max 5A. Maximum cable length: 1000 ft (305m). Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: CE.
-
Dewesoft d.o.o.
Sound Intensity MeasurementA perfect tool for sound intensity level measurement and noise source determination brought to an entirely new level by Dewesoft. The solution brings a simple and intuitive measurement process while offering the utmost precision and industry unmatched adaptability.
-
Surface Analyst -
BTG Labs, Inc.
The Surface Analyst is a fast, easy, accurate, and non-destructive instrument that quantifies your level of surface preparation from the lab to the manufacturing floor. In 2 seconds, the Surface Analyst determines the surface cleanliness level by providing the contact angle measurement and a pass/fail result.
-
Boonton Electronics
Audio analyzer provides fast, accurate measurements including frequency, AC or DC level, distortion, SINAD and signal-to-noise ratio. It also includes an audio source providing accurate low distortion signals over wide frequencies and level ranges.
-
SG-IT -
Wuhan Sangao Electrical Test Installations Limit Co.
Features and benefits:1.High level of isolation2.High quality neutral-ground bond3.High level of common-mode noise rejection4.Conversion from Delta to Wye or the other way around5.Easy to change voltage taps6.Custom design for specific system
-
SCR ELEKTRONIKS
The high Voltage also known as di-electric withstand tester comes with customized facilities like voltage rampup rate zero interlock, Plus the user may specify the voltage level and leakage milliampere level so as to suit its testing needs.
-
Precision Milimeter Wave
Standard gain horns can be used to experimentally determine the gain of other antennas by using the substitution method. The standard gain horn and the antenna under test are alternately connected to a well matched detector system in order to compare their relative power levels. The power level difference is then added to the appropriate level of the calibration curve to determine the absolute gain of the antenna under test.View more Standard Gain Horn Antennas
-
3012 Series -
Accu-Scope Inc.
A clinical level microscope for routine applications in medical, veterinary and university labs.
-
-
J2140A -
PICOTEST Corp.
Characteristic RatingMaximum Input Level +20dBm3dB Frequency Range DC ~ 50MHzMaximum VSWR 1.3Attenuation Accuracy 0.2dB