Showing results: 1 - 15 of 75 items found.
-
KVJS-7000 -
KV Hipot Power Test Equipment Co.,Ltd
Insulation oil dielectric loss and resistivity tester is mainly used to test dielectric loss factor and resistivity of insulation oil and liquid insulation medium.
-
KVIO-80 -
KV Hipot Power Test Equipment Co.,Ltd
Automatic Insulation Oil Breakdown Tester Is Used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool etc.
-
-
Sivananda Electronics
The test kit is fully automatic and has the facility forAuto/Manual selections. The operator simply needs thesample in the test vessel & selects the required test. Testingcan be done as per many international ( IEC & Europeanstandards ) which are programmed into the instrumentmemory . Stand time, Stir times & Rate of rise of appliedvoltage can be selected in Custom Mode also , one setof such selected mode can also be stored in the memory. In addition to the above set can also perform withstand test(proof) tests. In this test the set allows the set voltage to pre-set value & hold for one minute to see if breakdown occurs. The backlit LCD is used for user friendly operationsduring the test process. It also display fault condition messages such as open ground and cover open . All the user selected programmes are chosen through(4x3) key pad.The test results can be printed along with with test type, date, time, breakdown test voltage, averages and deviations. Voltage value can be measured & printed with a resolution of 0.1kV. In reprint option it is possible to have number of printouts for the last test. For each test the readings are recorded and stored in memory.
-
HDIIJ-80 -
HD Power Test Equipment Co.ltd
Automatic Insulation Oil Dielectric(breakdown) Tester is used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool, electric manufacturer and etc. It adopts full auto digital microcomputer, which has the function of high accuracy, strong anti-interference ability and safe reliability
-
DAC-5016 -
Soken Electric Co. Ltd
DAC-5016 is an automatic test system of insulation oils according to JIS C-2101.The system automatically enables changing over samples (liquid cells) up to max 8 pieces and testing the dielectric loss tangents and the volume resistivities.In automatic mode, the dielectric loss tangents and the volume resistivities are automatically measured, and then the results are printed out with the built-in printer. And the relative permittivities and the volume resistivities calculated are also printed out. Therefore the test time is greatly saved compared to the conventional test methods.
-
STY Series -
Chongqing Assen Power Equipment Co., Ltd
STY series three cups insulation oil dielectric strength tester uses a microprocessor to automatically complete boost, keep stirring, static discharge, calculate, print and other operations, is a necessary measure in the conventional test equipment.
-
-
Stoil Cell -
Altanova Group
The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination.
-
SG-YD -
Wuhan Sangao Electrical Test Installations Limit Co.
AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.
-
HDLT -
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
-
YD-Series -
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
YD series HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the YD series HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.The tester is consists of single HV transformer and main control box. There are two kinds of HV transformer according to the insulation materials of the HV transformer.They are dry HV transformer and oil HV transformer. For the dry HV transformer the insulation material is epoxy resin.For oil HV transformer the insulation material is insulation oil. The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication
-
SG7808 -
Shanghai Jiuzhi Electric Co., Ltd.
For many electric equipments used in power system and enterprises, inner insulation is mostly oil-insulated. Oil dielectric strength test is one of the essential routine tests. SG7808 Oil Dielectric Test Set is the ideal testing device for oil dielectric strength. The test sets are fully automatic.
-
GC2010D -
Chongqing Kailian Yongrun Industrial Co.,Ltd.
Transformer uses oil as coolant and insulator. Gases are formed within the transformer oil due to natural aging, faults from oxidation, vaporization, oil breakdown, electrolytic action or insulation decomposition. Because the transformer oil bathes each internal component, dissolved gases in the transformer oil contain lots of diagnostic information. Meanwhile, the transformer is very expensive to be replaced, so monitoring these gases is very important to know the current quality of transformer or even when the transformer should be removed from service before failure. Presence of each gas composition and its concentration indicates possible failure of transformer.