Filter Results By:

Products

Applications

Manufacturers

Instruments

read precision values.

See Also: Instrument Cables, Instrumentation Amplifiers


Showing recent results 1516 - 1530 of 4245 products found.

  • High Voltage EMC Surge Generator

    TM510 - T&M Tools Limited Co

    TM510 Surge Generator is mainly used for testing power cable high-resistance and arc-over fault whose grade range is 0-10kV, co-operating with cable fault tester and locating devices to test and locate faults. If the user choose the professional digital milli-ampere-meter, as for cable with grade range about 0- 6kV, the instrument can also be used to do DC&voltage resistance test and current leakage test after the fault is repaired. The instrument is internally equipped with voltage-rise rectifying and discharging device, has complete functions, and is also convenient and safe to be wired and operated.

  • Insertion/Return Loss Test Station

    JW3327 - Shanghai Joinwit optoelectronic Tech,co.,Ltd

    JW3327 Insertion/Return Loss Test Station is a Joinwit precise instrument, which be adopted advantages from current abroad instrument brand and improved to the application from clients, developed by Joinwit. It is a technological breakthrough in the domestic market and greatly improves the efficiency of IL test of optical devices to the MM with two wavelengths testing result in one station. It has extensive applications in the fiber cable, fiber passive device, fiber active device and optical communication system. It is suitable to perform the WIP testing and sample character testing for fiber device manufacturer research institutes.

  • Modbus Data Logger

    Ajinkya Electronic Systems

    Modbus is a popular protocol that is used by manufacturers of instruments and sensors. Site instrumentation already exists and parameters to be recorded are available on Modbus Data Logger. We have in store fro our clients Modbus Data Logger that can read data from these instruments and record them periodically. These loggers are configured as per the site requirements. Though basic operation of any data logger is to record the values of process parameters. However it is important that recorded data is presented to the user in timely and prescribed manner. Also any discrepancies in the readings are conveyed to the operator in the fastest manner for quick action.

  • Phase Angle Voltmeter

    2600 - Clarke-Hess Communications Research

    The Model 2600 Phase Angle Voltmeter replaces the very popular Model 2500A. With the latest and most advanced DSP technology, this instrument provides a new level of performance and user friendliness. In addition, the Model 2600 Phase Angle Voltmeter is considerably less expensive than other "traditional" Phase Angle Voltmeters. By keeping classic measurements, "at the touch of a button", the Model 2600 behaves more like an instrument and less like a computer. The unit is extremely easy to use yet contains a host of features and performance characteristics that set it apart from all others.

  • PXI Matrix Switch: 8x32, 1-Wire, 100Vrms/2A, Armature Relays

    M9122A - Keysight Technologies

    The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block orstandard cable connections.

  • RF Record and Playback Test System Stream RF Data to and from Hard Disk

    NI

    The high-bandwidth PCI and PCI Express data buses of PXI enable instruments to stream live signals to and from hard drives at up to 3.2 GB/s. NI RF record and playback systems combine PXI RF signal analyzers and RF signal generators with RAID arrays for high-speed, long-duration recording and playback. With the ability to generate or acquire terabytes of continuous data, PXI instruments can help you test receivers using real-world signals that are captured with an antenna. As a result, you can observe how receivers are able to adapt to common impairments in their deployment environments.

  • Sound Level Meters & Noise Meter

    Cirrus Research plc

    Cirrus offers a range of Class 1 and Class 2 hand-held sound level meters and accessories to cover all noise measurement applications from simple noise tests to detailed noise analysis. Our range of Sound Level Meters and Noise Meters spans simple instruments that provide the measurement of Sound Level, Integrating-Averaging instruments that provide Leq and occupational noise functions as well as precision data logging sound level meters with 1:1 & 1:3 real time octave band filters and in-measurement audio recording.

  • Termination & Repair Tool Kit

    OMK-SR-UNI.2 - OPTOKON a.s.

    OMK-SR-UNI Termination & Repair Tool Kit is designed for harsh environmental connectors. Tool Kit is delivered in aluminum case suitable for field applications. Tool Kit includes all necessary instruments and accessories for termination of harsh environment fiber optic connectors. All instruments are placed in special pre formed plastic foam secures tooling during transit and allows simple checking inventory. Tool Kit is designed for harsh environmental conditions use: water resistant, temperature range -40 °C to +80 °C, resistant to UV and magnetic emission.

  • Teslameter

    FM 0.2T 0.2T 12T - Projekt Elektronik Mess- und Regelungstechnik GmbH

    The Teslameter FM 0.2T / 0.2T / 12T consists of three autonomous magnetic field measuring instruments to measure the center field and stray field of superconducting magnets. The “center field” part of the instruments can measure the magnetic field up to a flux density of 12 T. Three measuring ranges (±20 T, ±2 T and ±200 mT) are available. The “stray field” parts are designed to measure stray fields. They can measure magnetic fields up to 0.2 T with a tolerance of ±0.5 %. Here, the measuring ranges ±200 mT, ±20 mT and ±2 mT are available.

  • Test Compliance

    MX CTS Series - AMETEK VTI

    A growing number of electronic products manufactured today have to meet international regulatory requirements for emissions and immunity. This is particularly true for products sold in the European community as well as a growing list of countries in the Far East. The California Instruments MXCTS System provides a cost-effective test solution aimed at verifying higher power product compliance to a number of AC and DC related harmonized test standards. The MXCTS system offers many of the same features and capabilities of the California Instruments CTS Series product line already in use at many EMC labs around the world.

  • VXI GPIB Command Module, C-Size

    E1406A - Keysight Technologies

    The Keysight E1406A Command Module is a C-size, 1-slot VXI message-based commander that provides Slot 0 and Resource Manager function. It can act as a VMEbus system controller and GPIB (IEEE-488)-to-VXIbus interface device for transparently communicating with any manufacturers message-based VXI modules. The E1406A Command Module has FLASH memory for downloadable drivers, so you can program Keysight register-based devices using the high-level SCPI programming language. It also translates SCPI commands for register-based instruments and therefore, makes these VXI devices as easy to program as message-based instruments.

  • Scanning Probe Workstations.

    BioLogic

    BioLogic has over 25 years of experience producing scanning probe electrochemistry instruments. Initially this included a number of single technique instruments, with the first modular scanning electrochemical workstation, the M370, introduced in 2006, under the Uniscan name.Scanning probe electrochemistry has found use in academic and commercial research settings. It is applicable in any field in which bulk electrochemical measurements have been used. Scanning probe electrochemistry has found widespread use in: Corrosion and coatings, Biology, including biosensors and biotechnology, Batteries, fuel cells and photovoltaics, Materials, Catalysis

  • Benchtop Unit for Universal Coating Thickness Measurement

    FISCHERSCOPE MMS PC2 - Helmut Fischer AG

    Coating thickness measurement and material testing with just one instrument!Compact and extremely versatile desktop multi-function measuring system with data archiving and measurement data processing capabilities.User-friendly operation with large, high-resolution color LCD touch screen. Windows CE based.Many different plug-in testing modules allow numerous instrument configurations to meet the needs of the user. The modular design allows the upgrading of the instrument at any time. Similar or different modules can be installed depending on the applications.Different physical measurement principles are applied by the plug-in modules BETASCOPE, SIGMASCOPE, PHASCOPE, DUPLEX, NICKELSCOPE, SR-SCOPE and PERMASCOPE, Details see brochure.Multi-channel measurements at up to 8 measurement locationsA great variety of probes for different test piece geometries and measuring ranges are available.Delivery with PC software FISCHER DataCenter with the following functionality: Transferring and archiving measurement data, comprehensive statistical and graphical evaluations, easy creation and printing of inspection reports

  • Handheld Turns Ratio & Winding Resistance Tester

    TWR-H Series - IBEKO Power AB

    Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.

  • Transformer Test Equipment

    IBEKO Power AB

    DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.