  • Precision Lab Calibrator

    3001 - Martel Calibrators

    The Precision Lab Calibrator combines the power and features of the venerable M2001 lab calibrator, with the addition of an isolated measurement channel. This isolated measurement channel consists of two (2) voltage ranges: 10V and 100V DC, MilliAmp range 0 to 52 mA, MilliAmp range with simultaneous 24VDC power, selectable 250 Ohm HART resistor and accuracy of 0.005% of reading on voltage ranges.

  • Multifunction Field Calibrator & Communicator

    MC6-Ex - Beamex Oy Ab

    The MC6-Ex is an intrinsically safe field calibrator and communicator. It is ATEX and IECEx certified and can be used in all hazardous zones / divisions. The MC6-Ex includes a field communicator for HART, FOUNDATION Fieldbus and Profibus protocols. Each calibrator is delivered with a traceable, accredited calibration certificate as a standard. t is a documenting, multifunction calibrator and communicator that offers calibration capabilities for pressure, temperature and various electrical signals.

  • Process Industry Head Thermometers

    ABB Ltd.

    Rough environmental conditions, hazardous areas, space-saving installation and flexible assembly are only some examples of the skills of our daily proven and reliable temperature sensors. With direct sensor output or 4 to 20 mA HART, PROFIBUS, FOUNDATION Fieldbus or WirelessHART communication, including device configuration with LCD display. Available without thermowell or with welded or drilled thermowell for sensor protection. Available also for non-invasive temperature measurements with high precision.

  • Process Analyzers

    Knick Elektronische Messgeräte GmbH & Co. KG.

    Industrial meters for pH, ORP, conductivity and oxygen. In 2- and 4-wire technology, explosion-proof.Bus Communication: HART, FOUNDATION Fieldbus, Profibus DP and PA. Robust industrial housing with high IP protection. Suitable for outdoor use. For analog and digital sensors. Simple intuitive operation. From DIN rail transmitters up to the modular system.

  • Field Communicators

    Beamex Oy Ab

    We offer modular multi-bus field communicators for HART, FOUNDATION Fieldbus H1 and Profibus PA protocols, combined in some of our process calibrators. While the communicator is built in the same device with the process calibrator, they can communicate seamlessly offering better user experience than separate calibrator and communicator. Plus you only need to carry one device. Thanks to the modularity you can select which protocol you take, and update more protocols later on, if needed.

  • Continuous Measurement With Float

    WIKA Alexander Wiegand SE & Co. KG

    Our level sensors enable the continuous detection of levels, independent of physical and chemical changes of the media such as foaming, conductivity, dielectric, pressure, vacuum, temperature, vapours, condensation, bubble formation, boiling effects and density change. Via the HART® interface, parallel measurement of interface layer and overall level is possible. The level can be displayed proportional to height or volume. Process connection, guide tube and float can be manufactured from stainless steel 1.4571, 1.4435, 1.4539, titanium or various plastics.

  • Infrared Gas Detector

    iTrans2 - Teledyne Gas & Flame Detection

    The iTrans2 infrared gas detector employs an intelligent electronics platform to provide one or two points of detection from a single head for maximum flexibility, superior performance and lower installation costs. With the optional HART Communication Protocol, the iTrans2 offers remote diagnostics, set-up or calibration by superimposing a high-frequency current across the industry standard 4-20mA analog line.

  • Signal Isolators

    Datexel

    Signal IsolatorsDatexel manufacture a large range of Signal Isolators. The DAT511 is a loop powered isolator with 3000 V galvanic isolation between the input and output. It is a 2 wire device so there is no external wiring. The DAT511H is similar but is Hart compatible. The DAT4035 is a universal input signal (Thermocouples, RTD's, mV, Volts, mA, resistance and potentiometers) conditioner with 2000 V isolation between the input and output and it is PC programmable. It is a 2 wire loop powered device. The DAT4135 is similar but it is a 4 wire device so it has the ability to boost the output or provide a voltage output.

  • Ultrasonic Level Transmitter

    USonic - AMETEK Drexelbrook

    The Drexelbrook family of Ultrasonic technology level products offers an affordable two wire and line powered version for non-contact level measurement of liquids and slurries for level, distance, volume and open channel flow.Measurements of level, distance, volume and open channel flow is easily configured through the menu driven display. The Usonic level transmitter is offered with a two wire 4-20 mA, Hart output signal and is suitable for all Class I Div. 1, Zone 0, I.S. or XP locations. The bench configuration eliminates the need to move process material levels for calibration.

  • Process Control Actuators

    SM-6000 - Rotork plc

    *Torque range up to 35,256 Nm (26,000 lbf.ft)*Up to 313° rotation*Double O-ring sealing*Continuous unrestricted modulating duty*Manual override standard*HART®, Profibus® & Foundation Fieldbus® available*Automatic torque limiting*Self-locking drive system to hold in last position and prevent backdriving up to 125% of torque rating*AC input power (1-phase and 3-phase)*Temperature range from -40° F to 185° F (-40° C to 85° C)*Manual override standard

  • Fixed Gas Detectors

    DG7 Series - Teledyne Gas & Flame Detection

    All DGi-TT7 are constructed from a common housing and electronics with the detection properties being determined by the type of sensor (cartridge) used. A wide range of cells are available, these cells are intrisically safe protected, and may be replaced with the detector powered which minimises the system down time. The intelligent, microprocessor driven unit is fully configurable using a wireless hand-held terminal (TLU) or by using the hard wired HART option giving true flexibility to the installer and reduced service costs.Elements such as relay operation and alarm levels are all set via the TLU, a hazardous area approved hand-held unit. The unit may be interfaced directly with a wide range of panels, controllers and PLC’s etc. Its integral daylight readable alphanumeric display indicates local status and alarm level.

  • Metal Tube Float Flow meter

    F56 - Beijing Airport Beiguang Instruments Co., Ltd

    F56 Metal Tube Float Flow meter Series are used for measure instantaneous and accumulated flow rate of liquid, gas and steam in closed pipelines. It is suitable for metering flow value on site or electronic remote. The measuring principle is based on the hydrodynamic effects,This makes float moving from bottom to top in vertical Pipe. As the displacement of float is in related to flow rate, which can be read from the indicator by means of the magnetic drive system in non-contact form . Also, flowmeters output electrical signal (4-20)mA / hart communication protocol with high / low limit Warning switches/integrating flow PCB broad can be configured.

  • Isolation Amplifier

    Mornsun Guangzhou Science & Technology

    An isolation amplifier is an amplifier that provides isolation between the input and output of the circuits, including isolation between their associated power supplies. MORNSUN offers different types of analog isolation amplifiers, such as acquisition type signal conditioning modules, output isolation signal conditioning modules, two-wire loop power supply signal conditioning modules and signal isolators, etc. These analog isolation amplifiers feature excellent temperature drift characteristics of less than 50PPM/℃ across the entire operating temperature range of -40 ℃ to +85 ℃ and achieve isolation transmission, signal conversion (programmable for some models), HART communication, signal amplification, port protection and other functions. SIP, DIP, SMD and DIN Rail packages are optional.

  • Series Flame Detector

    DF-TV7 - Teledyne Gas & Flame Detection

    The device offers a wide range of output options, as standard and is suitable for use in SIL 2 applications. The detector can ​​be configured to communicate with a wide range of fire panels, controllers, and PLCs and offer HART 7 and Syntel (Lonworks) protocols for addressable event monitoring. The devices come standard with a configurable 4-20mA or 0-22mA (PLC) output, two configurable alarm relays, and two detector status LEDs.All MultiFlame detectors are equipped with a continuous optical lens auto-check to ensure that the optical path is clear and that the detector functions properly. Sensors can be replaced easily in the field without removing any cable glands. Devices are easy to test and configure using a TLU600 wireless hand-held unit that is approved for use in hazardous areas. The TLU600 can also be used for wireless testing of the optical and output circuits. The TLU600 can also be used for wireless testing of the optical and output circuits.​​​​​​​​​​​​​​​​​​​​