Filter Results By:

Products

Applications

Manufacturers

Showing results: 1 - 12 of 12 items found.

  • Ground Resistance Clamp Meter

    61-920 - IDEAL Industries, Inc.

    *Auto ranging*Auto power off*Hard case included*2-year warranty

  • Earth Ground Resistance Meter

    1623-2 - Fluke Corporation

    The Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps.

  • Earth Ground Tester

    1625-2 - Fluke Corporation

    The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes.

  • Earth Ground Tester

    Fluke 1625-2 GEO - Iconic Engineering Limited

    The Fluke 1625-2 earth ground tester measures earth mishap resistances victimization solely clamps, solely stakes, or one clamp and stakes. With the stakeless check methodology, the Fluke 1625-2 is in a position to live earth mishap resistances for multi-grounded systems victimization solely current clamps. this method eliminates the harmful, and time intense job of disconnecting parallel grounds, and finding appropriate locations for auxiliary ground stakes.

  • High Voltage Insulating Tester

    Soken Electric Co. Ltd

    Suitable for preventive maintenance of gapless arresters.By simply clamping around the ground wire of an arrestor with a clamp CT, it detects leak current and leak current resistance components.

  • Earth Ground Resistance Meter

    Fluke 1623-2 GEO - Iconic Engineering Limited

    Fluke 1623-2 GEO Earth Ground Resistance Meter Performs stateless earth ground rod testing (two clamps). One of the most important things about Fluke 1623-2 earth tester always provides accurate results in any environment.

  • Earth Ground Clamp

    1630-2 - Fluke Corporation

    The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes.

  • Easy Pole Clamp-On Ground Resistance Tester w/ Super Slim Jaw

    FT6380 - HIOKI E.E. Corp

    The FT6380 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.

  • Ground Fault Finder

    FST-JD200 DC - Foresight Electronics Co., Ltd.

    FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...

  • 200 A Safety Ground Tester With Built-In Thermal Printer

    SGT-200 - Manta Test Systems

    The Vanguard SGT-200 Safety Ground Tester is a 200A DC micro-ohmmeter designed specifically to measure the resistance of protective in-service grounding and jumper cable assemblies. The SGT-200 can measure the resistance of the grounding cables, clamps and ferrules. The measured resistance values can be compared against the calculated values (using the ASTM 2249-03 standard) and a Pass/Fail result can be printed along with the measured resistance values. Since the SGT-200 uses a DC current, there is no need to uncoil the cable under test. It can be conveniently tested in its coiled state in a much smaller testing enviornment.

  • Digital Ior Leakage Current Clamp Tester

    MCL-400IR+ - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).

  • Ground Grid Tester

    GGT Series - IBEKO Power AB

    The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.

Get Help