Filter Results By:

Products

Applications

Manufacturers

Showing results: 16 - 30 of 116 items found.

  • Practical Use Precision Type Comparison Blackbody Furnaces

    IR-R6, IR-R7, IR-R8 - Summit

    Practical use precision type comparison blackbody furnaces cover the temperature range of 100 to 3000°C by 3 kinds of blackbody furnace and calibrate radiation thermometers accurately.

  • Microwave Furnace for Ash, Bone Content & Carbohydrate Analysis

    Phoenix - CEM Corp.

    The Phoenix line of microwave muffle furnaces offers unmatched versatility and speed in a rugged, easy-to-use system. Choose from two configurations and a variety of options!

  • High Temperature Self-Supporting Furnace Extensometers (1200 C)

    Model 3448 - Jinan Testing Equipment IE Corporation

    Epsilon developed this unique high temperature extensometer for testing metals, ceramics, and composites at the high temperatures produced by furnaces and induction heating systems. A combination of features make these extensometers easier to use and better in performance than other similar high temperature extensometers.The units are held on the specimen by light, flexible ceramic fiber cords. These make the extensometer self-supporting on the specimen. No furnace mounting brackets are required. The side load on the test sample is greatly reduced because of the self-supporting design and light weight of the sensor. Most materials testing furnaces with a side cut-out for an extensometer will readily accept a Model 3448. For induction heating systems, a different ceramic cord placement allows the extensometer to easily pass between the coils.The combination of radiant heat shields and convection cooling fins allow this model to be used at specimen temperatures up to 1200℃ (2200°F) without any cooling. An optional tiny air fan does enhance stability at the highest temperatures and is recommended for the highest accuracy and for tests with small elongations. The fan comes with a magnetic base for support so it can be mounted at any convenient location near the extensometer. Fan cooling is not generally needed for induction heated systems. High purity alumina ceramic rods are used. These are available in lengths as required to fit your furnace. A spare set is included with every extensometer. Specify chisel, vee chisel or conical contact points as desired.Most units operate equally well in tension and compression. Thus tensile, compression and cyclic tests like low cycle fatigue can all be performed with a single unit.For vacuum furnaces, special models are available. Epsilon can also provide a radiant heat transfer cooled version. This requires that the extensometer module be surrounded by a water cooled enclosure with a front slot for the ceramic rods.

  • 1 kW and 2 kW Laser-Based Floating Zone Furnace

    Laser Furnace - Quantum Design Inc.

    The 1 kW and 2 kW laser furnace for single crystal fabrication is based on a design and developed in close cooperation with the RIKEN Center for Emergent Matter Science under the leadership of Yoshio Kaneko. Both melting zones have 5 lasers each, which guarantees a high uniformity of power density in the melting zone range. The laser profile has been optimized to reduce thermal stress during the crystal growth process. In addition, the system includes an integrated temperature sensor for real-time temperature monitoring. Temperatures up to 3000 °C can be reached and therefore materials with a very high vapor pressure, a narrow temperature range of the melt, a high thermal conductivity coefficient and incongruent melts can be melted.

  • High Temperature Furnace COD Gages (1200 C or 1600 C)

    Model 3548COD - Jinan Testing Equipment IE Corporation

    These COD gages mount on a water-cooled bracket, which is mounted on the furnace side cut-out or with optional load frame support brackets. The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. Mounting brackets may be integrated with the furnace cut-out. Epsilon can also provide optional load frame mounting brackets to fit your test frame. Contact edges on the test sample should be somewhat rounded (not sharp knife edges) for best performance with this model. The Model 3548COD extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • High Temperature Hot Mountable Furnace Extensometers (1200 Cor 1600 C)

    Model 3549 - Jinan Testing Equipment IE Corporation

    The Model 3549 is a major advancement in the design of externally mounted, furnace extensometers. This new extensometer is designed to meet the stringent requirements of strain controlled testing as prescribed in ISO 6892, while introducing many new innovative features that help improve productivity with static testing applications (tension and compression testing) and long term testing such as low cycle fatigue and creep. The overall design reduces any influence from common lab environment vibrations. This unit also incorporates a new feature that allows the user to precisely set the contact force against the test specimen. This allows for even and repeatable contact force, limiting contact force induced errors. This extensometer mounts on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The gauge length for the 3549 is automatically set prior to mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.

  • Carbon / Sulfur Analyzer

    ELEMENTRAC CS‑d - ELTRA GmbH

    ELTRA's ELEMENTRAC CS-d is the only analyzer in the market for determination of carbon and sulfur in organic as well as inorganic samples. For this purpose, the ELEMENTRAC CS-d is equipped with both an induction and a resistance furnace (ELTRA Dual Furnace Technology), covering the full range of carbon and sulfur analysis.

  • High-Temperature Extensometers < 950 °C Capacitive

    Instron

    Is typically used in hot tensile applications with tube type furnaces and consist of a separate measuring unit and suspension arm assembly. The measuring unit uses an LVDT with a fixed travel that remains outside of the furnace, the arms are located mostly inside of the heating system and attach the specimen to the measuring unit.

  • Systems Engineering Projects

    Precision Development Consulting Inc

    Furnace Automation, LED Materials System, Batch CVD System, Source Evaluations, Field Audits

  • Carbon / Water Analyzer

    CW‑800M - ELTRA GmbH

    ELTRA’s CW-800M analyzer is designed for fractional analysis of carbon and water in one single operation. It is based on the proven technology of the CW-800 but has a modified furnace which allows fast adjustment of the temperature in the furnace. Different fractions of carbon and water of the sample are analyzed by applying different furnace temperatures. ELTRA’s CW-800M analyzer is designed for the precise, simultaneous determination of carbon (released as CO2) and water in lime, gypsum and cement from trace level up to 100 % (depending on sample weight). Other sample materials include ores, soil, minerals, slags and waste.

  • Thermogravimetric Analyzers

    TGA THERMOSTEP - ELTRA GmbH

    ELTRA TGA analyzers are an ideal alternative to standard laboratory ovens and muffle furnaces for thermogravimetric analysis. Thanks to a programmable furnace that is connected to an integrated balance, heating and weighing are combined in one instrument. This saves time-consuming manual work and allows for high sample throughput. In addition, typical parameters such as moisture, ash and volatiles can be determined in one analysis run.

  • Carbon Residue Testers

    Labodam

    Carbon residue tester (conradson methods), carbon residue tester (digital temperature controlled electric furnace methods)

  • Carbon/Sulfur Analyzer

    EMIA-Step - HORIBA, Ltd.

    In addition to the “EMIA-Expert/Pro” series of high-frequency induction furnace type, the “EMIA-Step” of tubular electric resistance heating furnace type has been newly added to our Carbon/Sulfur Analyzers lineup. It realizes highly accurate and sensitive analysis, and its variable heating temperature function enables the quantitative analysis by separating it by temperature and condition as well as whole quantity analysis.

  • High Temperature Blackbody Source

    Pegasus R Model 970 - Isothermal Technology Ltd

    Compact High Temperature Source 150C to 1200C E >0.995. The Pegasus R is a compact furnace for calibrating radiation pyrometers.

  • Impedance Analyzers

    HTF-1100. - BioLogic

    A laboratory furnace used specifically for the electrical characterization of materials and also for heat treatment between ambient temperature and 1100 °C.

Get Help