Filter Results By:

Products

Applications

Manufacturers

Showing product results. 406 - 412 of 412 products found.

  • Analog Sensors

    Solar Light Company Inc.

    Solar Light’s NIST-Traceable PMA-Series Analog Sensors represent the pinnacle of accuracy, durability, and selection on the market today. Our sensors measure discrete bands of the electromagnetic spectrum from the UVA, UVB, UVA+B, UVC, Visible Light, and Infrared regions. Both narrow and broad bands are available, to fit any application, including germicidal applications, environmental probes, and sensors for biologically weighted spectra (such as the erythema and CIE action spectra.) Over 135 different sensors are available in a variety of packages to fit any environment, from indoor clean rooms to harsh locations outdoors to 100 meters under water. Please note that Solar Light offers both Digital Sensors and Analog Sensors in the PMA-Series lineup. Select these Analog Sensors if you don’t need a digital display output of the reading, if you will be connecting to your own datalogger, or if you plan to use a voltage source to provide excitation voltage to the sensor and a digital volt or amp meter to read and convert the results. Analog Sensors are typically used as process sensors that are permanently installed to provide ongoing information. Typical current draw is under 1mA. (By contrast, Digital models are typically used as discrete sensors that are portable and located to provide short term information.)

  • Precision Capacitance and Dissipation Bridge

    SG2008 - Shanghai Jiuzhi Electric Co., Ltd.

    SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (tgδ) and capacitance (C) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test such asHigh Voltage (EHV) class Bushings, Windings of transformer (1/2/3 windings), shunt reactors, Current Transformer, Capacitor Voltage transformer(CVT), grading capacitors of Circuit Breakers, Surge Arrester and other electrical equipments. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process.

  • RF Architect, Synthesis, Modulated RF Element

    W2372EP - Keysight Technologies

    The RF Architect, Synthesis, Modulated RF Element provides the industry's most powerful communication system architecture, frequency planning and circuit/system synthesis capabilities from Genesysto the Advanced Design System (ADS), the flagship product from Keysight EEsof EDA.Analyzes RF systems withdigitally modulated RF signals. It offers breakthrough budget analysis of EVM, BER, and ACPR on level diagrams which determine their contribution from each system component stage. You can then verify the system against LTE-3GPP and WLAN 802.11ac wireless standards. ADS is the only design simulation platform that enables the co-design of IC, package and board in high-frequency and hi-speed applications. It seamlessly integrates system, circuit, full 3D electromagnetic simulation with Keysight's test instrumentation for you to do single pass successful electronic designs.

  • Digital Sensors

    PMA-Series - Solar Light Company Inc.

    Solar Light’s NIST-Traceable PMA-Series Digital Sensors represent the pinnacle of accuracy, durability, and selection on the market today. Our sensors measure discrete bands of the electromagnetic spectrum from the UVA, UVB, UVA+B, UVC, Visible Light, and Infrared regions. Both narrow and broad bands are available to fit any application, including germicidal requirements, environmental probes, and sensors for biologically weighted spectra (such as the erythema and CIE action spectra.) Over 135 different sensors are available in a variety of packages to fit any environment, from indoor clean rooms to harsh locations outdoors to 100 meters under water. Please note that Solar Light offers both Digital Sensors and Analog Sensors in the PMA-Series lineup. Select these Digital Sensors if you prefer to plug into our PMA-Series Radiometers to read the output of the sensor on the meter’s display. Digital models are typically used as discrete sensors that are portable and located to provide short term information. (By contrast, please select Analog Sensors if you don’t need a digital display output of the reading, if you will be connecting to your own datalogger, or if you plan to use a voltage source to provide excitation voltage to the sensor and a digital volt or amp meter to read and convert the results. Analog Sensors are typically used as process sensors that are permanently installed to provide ongoing information.)

  • Trifield Meter

    100XE - Alpha Lab, Inc.

    The Trifield Meter is a gaussmeter, electric field meter, radio field strength meter in a single unit. When measuring electromagnetic fields (EMFs), the primary concern is usually magnetic fields, which can be tricky to measure. If a less sophisticated 1-axis gaussmeter is used, a reading of zero could result even where the field is strong. A 1-axis meter must be oriented correctly to measure the field (which is a vector). The 3-axis Trifield Meter solves that problem by measuring the true strength of the field regardless of which way it is oriented. Therefore, the Trifield Meter can be scanned rapidly across an area without having to stop at each point to search for the orientation that gives a maximum reading. Another section of the meter detects AC electric fields, which can exist independently of AC magnetic field. The third section detects radio/microwave, such as from a leaky microwave oven.

  • Near Field Probes 30 MHz up to 3 GHz

    RF6 set - Langer EMV-Technik GmbH

    The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Partial Discharge Testing Equipment

    AR700 - Scope T&M Pvt, Ltd.

    PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.

Get Help