Filter Results By:

Products

Applications

Manufacturers

Electrochemical

chemical action when combined with electricity.

See Also: Electrochemistry


Showing results: 106 - 114 of 114 items found.

  • EIS Battery Analyzer

    BA8100 - B&K Precision Corporation

    The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.

  • Surface Insulation Resistance Testing

    AutoSIR2™ - Gen3 Systems Limited

    One AutoSIR chassis can hold between 1 to 16 measurement cards and can monitor up to 256 x 2-point test patterns or 78 x 5-point test patterns, or 32 x 9-point test patterns at selectable intervals from minutes to days. Each channel is current limited (1 M Ω), ensuring that dendrites are preserved for failure analysis. The frequent monitoring capability provides a full picture of the electrochemical reactions taking place on a circuit assembly, and provides early trend analysis enabling tests to be curtailed, thus saving considerable test time and money.

  • Carbon Monoxide Detector, CO

    ENVIROMUX-CMD - Network Technologies Inc

    Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes; 150 ppm after 10 to 50 minutes; and 400 ppm after 4 to 15 minutes. Flush or surface mount. Test functionality of electrochemical CO sensing cell. Connect to RJ45 or digital input sensor ports. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1000 ft (305m). LED indicators for operation status and system test. Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL.

  • Long Term Test Kit

    Fiaxell Sàrl

    When long term electro-chemical tests (>1000 hours) are run to monitor the cell degradation at the cathode for example, it is important to avoid any contaminant in the gas flow rate.Inconel 601 flange equipped with alumina housing and alumina tube to feed the gas to the electrode during long term test (>1000 h)Typical poisoning is coming from the chromium contained in the steel tubing. The volatile chromium species (Cr6+) will flow into the cathode (with the air) and thanks to the intake of electrons at the electrode, the chromium ion will transform to chromium oxide and be deposited at the cathode triple point. In such a case, the long term test kit is used. The Inconel 601 flange is equipped with an alumina housing (>96 % Al2O3) and the air (or other gas) is led through an alumina tube. The long term test kit is fully compatible with other functionalities proposed with the Open Flanges™ test Set-Up as the integrated steamer or the small pellet test kit. The long term test kit can be implemented on the fuel, on the air or on both sides.

  • Hazardous Area Gas Detector

    Meridian - Teledyne Gas & Flame Detection

    Whether you need an infrared or catalytic bead sensor to detect combustible gases or an electrochemical sensor for a toxic environment, the Meridian universal gas detector utilizes a single detector head to easily accept all sensor types. There is no requirement for distinct personality boards in the gas detector or different detector heads to make the instrument behave as a combustible or toxic gas detector. The Meridian gas detector accepts all sensor types in one detector. Simply attach the specific toxic or combustible sensor to the universal detector head and the Meridian gas detector will automatically determine the type of gas to be detected. Installation of the sensor is a simple plug-and-play action. At Teledyne Gas and Flame Detection, we are always looking to anticipate your future needs. We designed the Meridian gas detection platform to be future proof, allowing you to take advantage of new sensing technologies from Teledyne Gas and Flame Detection while maintaining ease of use and peace of mind.​​​​​​​​​​​​​​​​​​​​​

  • Materials And Chemical Analysis

    Anderson Materials Evaluation, Inc.

    Materials characterization, failure analysis, quality control, and materials and process development services are offered.  Our analytical techniques allow us to assess elemental and chemical material composition, thermal properties, coating thickness, electrochemical properties, surface chemistry, surface wetting, corrosion rates and pitting potentials, contamination and degradation problems, metallography, fractography, phase transitions, static coefficient of friction, adhesive bonding strength and causes of adhesive bonding failures, surface tension and surface energy, tensile and compressive strength, bend deflection, lapshear strength, elasticity properties, UV and visible light absorption and reflection, density and porosity, and many other material properties integral to improving your products.

  • High-Temperature and High-PressurepH Electrodes

    UltraDeg - Corr Instruments, llc

    Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).

  • Alcohol Tester

    Shenzhen Graigar Technology Co.,Ltd.

    Electrochemical (fuel cell) alcohol sensor, Module changeable Test Range: 0.000-2.000mg/l (0.400%B.A.C; 4.000%oB.A.C; 4.000g/l;) Alarming level: Pass level: 0.090mg/L (could be modified) Fail level:0.250mg/L (could be modified) Accuracy: +/-10% Work temperature: -10oC-50oC Work humidity: <95%RH (No Dews) Battery: 2XAA NiMH batteries, rating capacity: 2.1AH Dimension lXbXh: (mm) 250X105X400 Indication manner: mg/l,mg/100ml,g/l ,%BAC,%oBAC optional Coin for single time: 0-15 (For 0, the tester can be tested without coin). Coin diameter: 20mm-28mm Coin thickness: 1.2mm-2.5mm Coins Capacity: about 200 pieces Straw capacity: 200pcs(⊄<=7mm) Breath sampling time: about 5 seconds continuous breath.

  • Nanogravimetric Measuring Instrument

    EUREKA - BioAge s.r.l.

    Eureka is a QCM / EQCM (Quartz Crystal Microbalance) nanogravimetric measuring instrument capable of mass measurements in the order of nano-grams and pico-grams. Eureka can be used with gas and liquids, the cells are made by BioAge and sold with the instrument. The tool is the most versatile among those existing on the market, with an excellent quality / price ratio. It is a portable instrument as it is powered only by the PC USB port. The instrument is extremely compact, light, reliable and designed according to the current state of microelectronics. To use Eureka simply connect it to a PC USB port and install the capture software, running in Windows ™ environment,which turns out to be very simple to use, so you can do the first experiments in a very short time. For liquid measurements Eureka is an electrochemical system, therefore, electrochemical and nanogravimetric measurements can be performed at the same time (EQCM). Eureka, if connected to a self-powered portable PC, allows to perform measurements and experiments in total freedom in environments where grid voltage is not available,or experiments that are carried out in large areas in total freedom of movement. Measurements can be made on liquids, thanks to the static cell or the flow cell, or BioAge is able to design and create customized cells according to the needs of the user, varying volumes, dimensions and materials. The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used. or use a gas cell designed for gas phase analysis, BioAge is able to design and produce customized cells according to the user's needs, varying volumes, dimensions and materials.The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used. or use a gas cell designed for gas phase analysis, BioAge is able to design and produce customized cells according to the user's needs, varying volumes, dimensions and materials. The instrument is very versatile because the frequency measurement range can range from 0 to 50MHz, depending on the quartz crystal used.

Get Help