Filter Results By:

Products

Applications

Manufacturers

Detectors

register the presence of a stimuli.

See Also: Metal Detectors, Particle Detectors, Sensors, Charge Sensitive Preamplifiers, Checkers


Showing product results. 631 - 645 of 679 products found.

  • Digitizer

    751Family - CAEN S.p.A.

    The 751 is a family of CAEN Waveform Digitizer able to perform basic waveform recording and run online advanced algorithms (DPP) of charge integration and pulse shape discrimination with constant fraction timing and zero-length encoding. Data is read by a Flash ADC, 10-bit resolution and 1GS/s sampling rate (2GS/s using half of the channels in DES mode), which is well suited for fast signals as the ones coming from fast organic, inorganic and liquid scintillators coupled to PMTs or Silicon Photomultipliers, Diamond detectors and others. The acquisitioncan be channel independent and it is possible to make coincidence/ anti-coincidence logic among diferent channels and external veto/ gating. Multiple boards can be synchronized to build up complex systems.

  • Oxygen/Nitrogen/Hydrogen Analyzer

    EMGA-930 - HORIBA, Ltd.

    This is a simultaneous oxygen, nitrogen & hydrogen elemental analyzer with high accuracy and repeatability suiting to cutting-edge technology's R&D as well as quality control in the market of steel, new materials, catalyst and so on. This is a new generation model optimized to fit to user's requests.The oxygen is measured as carbon monoxide and carbon dioxide by two non-dispersive infrared detectors, the nitrogen by a thermal conductivity detector and the hydrogen with non dispersive Infra Red detector as H2O.

  • Optical Meters

    Gamma Scientific Inc.

    The Gamma Scientific range of light meters includes handheld and benchtop models.  Configuration options include a wide range of sensors and calibrations in units including:  Luminous Flux (lumens) or Radiant Flux (Watts),  Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr),  Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr),  or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.

  • Longwave Infrared Thermal Camera

    FLIR A6780 SLS - Teledyne FLIR

    The FLIR A6780 SLS LWIR camera system makes it easy to measure temperatures of rapid thermal events and high-speed targets, making it an ideal choice for industrial, military, and manufacturing R&D applications. Thanks to its cooled, longwave Strained Layer Superlattice (SLS) detector, the A6780 provides faster snapshot speeds than other detectors for crisp images without motion blurring. Manual and remote-focus lens options provide flexibility to maximize the number of measurement pixels on the object of interest. Simple, single cable connectivity using Gigabit Ethernet provides complete camera control, plus data capturing in FLIR Research Studio software – so users can analyze and understand data faster than ever before.

  • Multi-angle Polarized Light Scattering Measurements

    LISST-VSF - Sequoia Scientific, Inc.

    In-situ measurements of P11, P12 and P22 elements of scattering Mueller matrix, (P11 is VSF) from 15-150º.VSF (P11) only at small angles, 0.05 to 10º in 32 logarithmic steps in angles.Only two detectors employed with absolute radiant sensitivity (A/W) calibration.Beam attenuation measured with optics similar to our LISST-100X.Roving Eyeball™ optics permit 1-degree resolution in angles between 15 -150º.Sampling rate at 3 seconds per measurement set (involves 3 turns of Roving Eyeball with unpolarized, vertical, and horizontal polarized laser).Daylight rejection by laser modulation.Dynamic range in VSF measurements extended via laser power modulation.Data from small and large angles in a single data stream, including depth and temperature.

  • Photoluminescence Spectrometer

    FLS1000 - Edinburgh Instruments Ltd

    The FLS1000 sets the standard in both steady state and time-resolved photoluminescence spectroscopy for both fundamental research and routine laboratory applications. The system is a modular fluorescence and phosphorescence spectrometer for measuring spectra from the ultraviolet to the mid-infrared spectral range (up to 5,500 nm), and lifetimes spanning from picoseconds to seconds. All of this can be achieved through various upgrade routes, either at the time of order or in the future. Whether you are studying photophysics, photochemistry, biophysics, biochemistry, material or life sciences, the FLS1000 will enable you to reliably and accurately measure luminescence spectra and kinetics using state-of-the-art sources, detectors, acquisition techniques, quality optics and precision mechanics. The large sample chamber will house practically any type of sample accessory.

  • Spectroscopic Personal Radiation Detector

    identiFINDER® R200 - Teledyne FLIR

    identiFINDER® R200 instruments are rugged, pager-sized Spectroscopic Personal Radiation Detectors (SPRD). They provide full ANSI N42.32 Personal Radiation Detector (PRD) compliance and feature next-generation solid state detector read-out technology that delivers ANSI N42.48 SPRD compliance with nuclide identification. The R200-G detects and identifies gamma radiation and the R200-GN additionally provides neutron detection capability. Law enforcement agencies and first responders use the R200 during routine traffic stops or high visibility events and in mass transit or critical infrastructure entry control points. The OneTouch Reachback™ feature uses the latest advancements in Bluetooth® and web server technologies to provide large-scale situational awareness by alerting others before arriving on-scene.

  • Full Band Scalar Network Analyzer Extenders

    ERAVANT

    Full band scalar network analyzer extenders are designed to extend low frequency scalar network analyzers to higher millimeterwave frequency ranges. These extenders offer a low cost means of producing millimeterwave scalar network analyzers while preserving the functionality and features that industry standard models offer. These extenders deliver a superior performance since they are assembled with SAGE Millimeter’s instrumentation grade frequency extenders (STE series), Faraday isolators (STF series), direct or programmable attenuators (STA series), directional couplers (SWD series) and waveguide detectors (STD series). The below standard offering covers the frequency range of 26.5 to 170 GHz. Specifications other than those listed below are available upon request.

  • Transistor Arrays

    Renesas Electronics Corp.

    Renesas' portfolio of transister arrays include NPN, PNP, NPN-PNP combination transistor arrays based on our complementary UHF-1 SOI process. This portfolio also includes ultra high frequency transistor arrays for VHF/UHF amplifiers, VHF/UHF mixers, IF converters, synchronous detectors. Dual long-tailed pair transistor arrays and Gilbert Cell UHF transistor arrays are also available for wireless communication systems, radio and satellite communications and high performance instrumentation.

  • Dual Digital Multichannel Analyzer

    780 MCA Family - CAEN S.p.A.

    The 780 MCA family integrates advanced firmware algorithms operating Digital Pulse Processing for Pulse Height Analysis (PHA). The processing algorithms can be easily adapted to different detectors and application ensuring effective data analysis even at high count rates. It provides advanced tools for configuring baseline restoration, pile-up rejection. Thanks to the two input simultaneous acquisition, the modules are able to manage coincidence and anti-coincidence logic between detectors, allowing the user, for example, to easily take advantage of background rejection or anti-Compton techniques. These MCAs may provide at the same time energy, time stamp and the digitized pulse in a configurable time window (e.g. including the rising edge region) in order to perform further online analysis. Acquisition settings and basic mathematical analysis are performed through the CoMPASS and MC2Analyzer software, providing energy spectra with up to 16k channels, which can be exported and imported in ASCII or N42.42 compliant files. CAEN further provides drivers for the supported communication interfaces; configuration software tools, C and LabVIEW libraries (CAENComm, CAENDigitzer, CAENDPP), demo applications and utilities.

  • Spectrometer

    Model 207 - McPherson, Inc.

    The Model 207 offers the user the most throughput and fastest aperture in a long focal length monochromator. This is ideal for photoluminescence and Raman spectroscopy applications. It is also available in a vacuum compatible version. Used in air and with a selection of gratings, the spectral range of the 207 extends from 185 nanometersm to 20 microns or more. Under vacuum range is extended down to 105 nm (depends on the grating.) Multiple ports are available for mounting accessories or CCD detectors, etc. McPherson SNAP IN gratings allow the alignment-free use of many different gratings. Easily view a wider spectral range or obtain higher resolution! You can retrofit years later and not have to worry about alignment with the McPherson SNAP IN approach. Our dual grating turret also accepts these easy to exchange gratings.

  • Spectrometer

    ULSi - Avantes Inc.

    The same quality Avantes is well-known for, now in an easy-to-install package: the ULSi is the ideal choice for any system integrator. Fiber optic spectrometers have been integrated into many end-user systems in almost all areas of research and detection. Now Avantes releases its first completely integrated spectrometer: one housing including the optimum Ultra Low Straylight optical bench and a miniaturized version of our flexible AS5216 electronics board. The ULSi is available with the three best-selling detectors Avantes offers: the Sony ILX554B with 2048 pixels, the Sony ILX511 with 2048 high pixels for extra sensitivity and the Toshiba TCD1304 high resolution 3648 pixels. The same wide range of slits, gratings and other options available in the mainline spectroscopy lineup are also available for the ULSi.

  • Spectrometers

    McPherson, Inc.

    Offers the user the most throughput and fastest aperture in a long focal length monochromator. This is ideal for photoluminescence and Raman spectroscopy applications. It is also available in a vacuum compatible version. Used in air and with a selection of gratings, the spectral range of the 207 extends from 185 nanometersm to 20 microns or more. Under vacuum range is extended down to 105 nm (depends on the grating.) Multiple ports are available for mounting accessories or CCD detectors, etc. McPherson SNAP IN gratings allow the alignment-free use of many different gratings. Easily view a wider spectral range or obtain higher resolution! You can retrofit years later and not have to worry about alignment with the McPherson SNAP IN approach. Our dual grating turret also accepts these easy to exchange gratings.

  • Exposure Level Tester

    ELT-400 - Narda Safety Test Solutions

    *Wide frequency range (1 Hz - 400 kHz)*Standard-compliant measurement*Acceptance measurements compliant with CE standard IEC/EN 62233 and Generic Standard IEC 62311*Limit value traces conforming to ICNIRP 1998, 2010 and EMF Directive 2013/35/EU*Real time measurement with RMS and peak detectors*External FFT signal analysis for determining the frequency components via three channel analog output (one channel for each spatial axis) e.g. with the aid of a digital oscilloscope.

  • Noise Dosimeters And Sound Level Meters

    MSP Corporation

    TSI's Quest™ Edge Personal Noise Dosimeters are shoulder mounted, providing ergonomic, convenient measurement. Handheld Quest sound level meters measure average sound pressure level over time. All units are compact, with large displays and intuitive interfaces to provide crucial information at a glance and in real-time. Our personal noise indicators and sound detectors make it easier to measure sound and noise levels in real-time, and determine the level of hearing protection necessary in a particular environment.

Get Help