Filter Results By:

Products

Applications

Manufacturers

Detectors

register the presence of a stimuli.

See Also: Metal Detectors, Particle Detectors, Sensors, Charge Sensitive Preamplifiers


Showing recent results 631 - 645 of 660 products found.

  • Digitizer

    740 Family - CAEN S.p.A.

    The 740 is a high channel density CAEN Waveform Digitizer family able to perform basic waveform recording and run online advanced algorithms (DPP) of charge integration. Both the elevate number of channels per board (32 for Desktop and NIM form factor, 64 for VME) and the DPP algorithm make the board a digital replacement of a traditional QDC. Data is read by a Flash ADC, 12-bit resolution and 62.5 MS/s sampling rate, which is well suited for mid-slow signals as the ones coming from inorganic scintillators coupled to PMTs, gaseous detectors and others. Sampling rate can be further reduced using the decimation feature. The acquisition can be channel independent and externally vetoed/gated. Multiple boards can be synchronized to build up complex systems.

  • Full Band Scalar Network Analyzer Extenders

    ERAVANT

    Full band scalar network analyzer extenders are designed to extend low frequency scalar network analyzers to higher millimeterwave frequency ranges. These extenders offer a low cost means of producing millimeterwave scalar network analyzers while preserving the functionality and features that industry standard models offer. These extenders deliver a superior performance since they are assembled with SAGE Millimeter’s instrumentation grade frequency extenders (STE series), Faraday isolators (STF series), direct or programmable attenuators (STA series), directional couplers (SWD series) and waveguide detectors (STD series). The below standard offering covers the frequency range of 26.5 to 170 GHz. Specifications other than those listed below are available upon request.

  • Longwave Infrared Thermal Camera

    FLIR A6780 SLS - Teledyne FLIR

    The FLIR A6780 SLS LWIR camera system makes it easy to measure temperatures of rapid thermal events and high-speed targets, making it an ideal choice for industrial, military, and manufacturing R&D applications. Thanks to its cooled, longwave Strained Layer Superlattice (SLS) detector, the A6780 provides faster snapshot speeds than other detectors for crisp images without motion blurring. Manual and remote-focus lens options provide flexibility to maximize the number of measurement pixels on the object of interest. Simple, single cable connectivity using Gigabit Ethernet provides complete camera control, plus data capturing in FLIR Research Studio software – so users can analyze and understand data faster than ever before.

  • Multi-angle Polarized Light Scattering Measurements

    LISST-VSF - Sequoia Scientific, Inc.

    In-situ measurements of P11, P12 and P22 elements of scattering Mueller matrix, (P11 is VSF) from 15-150º.VSF (P11) only at small angles, 0.05 to 10º in 32 logarithmic steps in angles.Only two detectors employed with absolute radiant sensitivity (A/W) calibration.Beam attenuation measured with optics similar to our LISST-100X.Roving Eyeball™ optics permit 1-degree resolution in angles between 15 -150º.Sampling rate at 3 seconds per measurement set (involves 3 turns of Roving Eyeball with unpolarized, vertical, and horizontal polarized laser).Daylight rejection by laser modulation.Dynamic range in VSF measurements extended via laser power modulation.Data from small and large angles in a single data stream, including depth and temperature.

  • Photoluminescence Spectrometer

    FLS1000 - Edinburgh Instruments Ltd

    The FLS1000 sets the standard in both steady state and time-resolved photoluminescence spectroscopy for both fundamental research and routine laboratory applications. The system is a modular fluorescence and phosphorescence spectrometer for measuring spectra from the ultraviolet to the mid-infrared spectral range (up to 5,500 nm), and lifetimes spanning from picoseconds to seconds. All of this can be achieved through various upgrade routes, either at the time of order or in the future. Whether you are studying photophysics, photochemistry, biophysics, biochemistry, material or life sciences, the FLS1000 will enable you to reliably and accurately measure luminescence spectra and kinetics using state-of-the-art sources, detectors, acquisition techniques, quality optics and precision mechanics. The large sample chamber will house practically any type of sample accessory.

  • Spectroscopic Personal Radiation Detector

    identiFINDER® R200 - Teledyne FLIR

    identiFINDER® R200 instruments are rugged, pager-sized Spectroscopic Personal Radiation Detectors (SPRD). They provide full ANSI N42.32 Personal Radiation Detector (PRD) compliance and feature next-generation solid state detector read-out technology that delivers ANSI N42.48 SPRD compliance with nuclide identification. The R200-G detects and identifies gamma radiation and the R200-GN additionally provides neutron detection capability. Law enforcement agencies and first responders use the R200 during routine traffic stops or high visibility events and in mass transit or critical infrastructure entry control points. The OneTouch Reachback™ feature uses the latest advancements in Bluetooth® and web server technologies to provide large-scale situational awareness by alerting others before arriving on-scene.

  • High Resolution Offline AXI Platform with CT Technology

    XCT-series - Matrix Technologies GmbH

    The XCT-series systems are manually loaded, automated X-ray CT systems which offer a solution for a variety of CT applications. These systems provide the highest possible flexibility in order to satisfy individual customer needs. Depending on the application, they can be equipped with different types of tubes and detectors to offer high-resolution or high-power solutions. Unlike most CT systems, the XCT-1000 features both volume analyzing and automatic processing of the slices. As the newest feature, this machine is available with a super high resolution setup, offering a CT voxel size less than 1µm. It is especially suitable for the inspection of small to medium production volumes or for the use in laboratory environments, production sampling or failure analysis. The applications range from consumer electronics and automotive li-ion batteries, component level inspection for wire bonds, micro-solder-joints on PCB‘s, casting parts and semiconductors.

  • Spectrometer

    Model 207 - McPherson, Inc.

    The Model 207 offers the user the most throughput and fastest aperture in a long focal length monochromator. This is ideal for photoluminescence and Raman spectroscopy applications. It is also available in a vacuum compatible version. Used in air and with a selection of gratings, the spectral range of the 207 extends from 185 nanometersm to 20 microns or more. Under vacuum range is extended down to 105 nm (depends on the grating.) Multiple ports are available for mounting accessories or CCD detectors, etc. McPherson SNAP IN gratings allow the alignment-free use of many different gratings. Easily view a wider spectral range or obtain higher resolution! You can retrofit years later and not have to worry about alignment with the McPherson SNAP IN approach. Our dual grating turret also accepts these easy to exchange gratings.

  • Spectrometer

    ULSi - Avantes Inc.

    The same quality Avantes is well-known for, now in an easy-to-install package: the ULSi is the ideal choice for any system integrator. Fiber optic spectrometers have been integrated into many end-user systems in almost all areas of research and detection. Now Avantes releases its first completely integrated spectrometer: one housing including the optimum Ultra Low Straylight optical bench and a miniaturized version of our flexible AS5216 electronics board. The ULSi is available with the three best-selling detectors Avantes offers: the Sony ILX554B with 2048 pixels, the Sony ILX511 with 2048 high pixels for extra sensitivity and the Toshiba TCD1304 high resolution 3648 pixels. The same wide range of slits, gratings and other options available in the mainline spectroscopy lineup are also available for the ULSi.

  • Spectrometers

    McPherson, Inc.

    Offers the user the most throughput and fastest aperture in a long focal length monochromator. This is ideal for photoluminescence and Raman spectroscopy applications. It is also available in a vacuum compatible version. Used in air and with a selection of gratings, the spectral range of the 207 extends from 185 nanometersm to 20 microns or more. Under vacuum range is extended down to 105 nm (depends on the grating.) Multiple ports are available for mounting accessories or CCD detectors, etc. McPherson SNAP IN gratings allow the alignment-free use of many different gratings. Easily view a wider spectral range or obtain higher resolution! You can retrofit years later and not have to worry about alignment with the McPherson SNAP IN approach. Our dual grating turret also accepts these easy to exchange gratings.

  • Components

    Teledyne RF & Microwave

    Microwave Solutions is a worldwide leader in the design, development, and manufacture of RF and microwave components. Our broad line of components operate in the 100 kHz to 26GHz range and include Attenuators, BAW Devices, Detectors, Isolators and Circulators, Linearizers, Mixers, and VCOs. For over 50 years our components have played key roles in sophisticated airborne and satellite communications equipment, navigation and guidance systems, radar and sonar equipment, telemetry electronics, surveillance, and reconnaissance systems, and high performance commercial test equipment.

  • X-RAY PHOTODIODES

    AMS Technologies AG

    The large active area high speed detectors can be fully depleted to achieve the lowest possible junction capacitance for fast response times. They may be operated at a higher reverse voltage, up to the maximum allowable value, for achieving even faster response times in nano seconds. The high reverse bias at this point, increases the effective electric field across the junction, hence increasing the charge collection time in the depleted region. Note that this is achieved without the sacrifice for the high responsivity as well as active area.

  • Triple Monochromator/ Spectrograph

    Omni-λTripple Series - ZOLIX

    Omni-λ 500 Triple Monochromator/ SpectrographThe Triple Monochromators/Spectrographs include three 500 mm focus monochromators which are with fine alignment. The first two monochromators as the dispersion subtraction are used to reduce the stray light. The third monochromator as dispersion sum configuration is used to improve the resolution. And each unit can work well as the monochromator, and the two unit can also be used as the double monochromator. The first and the second monochromator are the side entrance and double exits, the third monochromator is the double entrances and double exits, it is easy to connect the CCD and PMT, the single channel detectors. There are three import gratings in each monochromator, and the spectral range is located in deep UV region, the middle UV and visible region. Each grating reflectivity can be up to 70% in their spectral region. Mainly used in high grade Raman spectroscopy measurement, such as UV-resonance Raman spectroscopy.

  • Gasoline Engine Tachometer

    SE-1620 - Ono Sokki

    The SE-1620 is an engine tachometer that performs measurement of the number of revolutions of a gasoline engine by connecting an engine revolution sensor such as an ignition pulse detector. A 100-mm wide-angle meter is used for the display, and both analog output and pulse output functions are provided as standard.Simply attach an ignition pulse detector or one of our other compatible detectors to the engine to enable measurement of the number of revolutions of a gasoline engine. The inputs, outputs and input power supply are all isolated to ensure the output of analog and pulse signals with superior noise resistance and stability characteristics.

  • X-ray Analytical Microscope Super Large Chamber Model

    XGT-9000SL - HORIBA, Ltd.

    - Large chamber capacity (W x D x H) : 1030 mm x 950 mm x 500 mm- X-ray shield complying with JAIMAS0101-2001/ IEC1010-1 to protect you from X-ray exposure- Mapping area size up to 350 x 350 mm2- <15 µm spot size with ultra-high intensity without compromising sensitivity and spatial resolution- Dual types of detectors for transmission and fluorescent X-rays- Detectable element range down to C with a light element detector and He purge module

Get Help