  • Ultrafast Joulemeter

    Gentec Electro Optics, Inc.

    Measure every pulse at up to 200 kHz with MACH 6. Measure with 12-bit digital accuracy and capture up to 4 million pulses in real time. Our MACH 6 Joulemeter is the only instrument in the world that performs at this speed, and with this precision. It is designed to support our full complement of fast energy probes that include Silicon, InGaAs and Pyroelectric Detectors. Measure from pJ to mJ and from 0.35 to 2.5 m. Using the M6-Si detector and the M5-UC-QED accessory, you can make relative measurements at 266 nm.

  • USB Powered SOURCE

    USB-S - Applied Electromagnetic Technology

    The USB SOURCE (USB-S) consists of a family of pocket-sized highly stable comb generator with a single comb frequency. Powered by an external standard USB connector. Individual units available with frequencies of 1.8 MHz, 10 MHz, 64 MHz, 100 MHz, 133 MHz and 200 MHz. Custom frequencies are available, consult AET Sales for this option. An option is available to pulse the comb signal on/off at a slow rate to allow testing of receiver quasi-static detectors. The pulsed mode works for any comb frequency selected.

  • Wearable Networked Gamma Neutron Detector

    D3S NET - Kromek Group plc

    The D3S NET radiation detector is a fast and accurate radioisotope identification device (RIID) for gamma isotope identification and neutron detection. The data collected by this radiation detector is not only shown to the user via the mobile phone app but also sent to a central control screen showing data from every other SIGMA enabled detector on the network. The D3S NET detector unit houses larger detectors that provide identification of isotopes in seconds, alerting the user and your command centre of gamma isotope source, dose and any neutron detection.

  • X-ray Windows

    ARC Technologies

    X-ray devices have become ubiquitous in the marketplace. The X-ray device market is divided into Portable and Stationary product types. The Market is also divided by technologies like Analog, Computed Radiography (CR) and Digital Radiography (DR). The Digital Radiography market is further segmented into Flat Panel Detectors (FPD) and High Density Line Scan Solid State Detector. The applications include at a minimum; Medical, Non-Destructive Testing, and Security Detection has driven the rapid spread of X-ray instruments including a myriad of handheld devices.

  • 3-AXIS DIGITAL AC GAUSSMETER: 1-200 kHz

    IDR-200 - Integrity Design and Reseach Corp.

    Typical Applications include checking the frequencies and magnetic fields (BW: 1 kHz -200 kHz) produced by equipments such as computer monitors, television sets, video display terminals, induction heaters, industrial, Radar, scientific/medical equipment, walk-through/hand-held detectors and ground wave energy network; etc. For more information about VLF magnetic fields and the VLF gaussmeter , see the paper titled "Very-low-frequency electromagnetic field detector with data acquisition," IEEE Trans. Instrum. Meas.,vol. 58, no. 1, pp. 129-140, Dec. 2008. by S. Hanna.

  • Detector And FPA Testing

    Santa Barbara Infrared, Inc.

    The FPA Test Set (FPATS) interface to the detectors under test (DUT’s) is via a custom pedestal plate which provides both a conductive heat path to both the individual DUT’s as well as the field of view limiting aperture plate. This custom pedestal plate protrudes through the customer provided DUT interface printed circuit board (PCB) and makes physical contact with the rear of the DUT packages and the aperture plate when the FPATS is in the closed position. The pedestal plate is mounted to the ambient source plate and its temperature is actively driven by this subsystem.

  • Earth Magnetometer

    EM2 - Alpha Lab, Inc.

    The Earth Magnetometer Model EM2 measures small variations from location to location in the Earth magnetic field associated with buried magnetic masses. Unlike metal detectors, a magnetometer signal is not attenuated by rock, dirt, mud or water, so targets can be detected at great depth. (If D is the diameter of a mass of magnetizable material, the EM2 can detect it as deep as 40 times the diameter D, whether the mass is specifically magnetized or not.) It is the lightest weight and lowest cost magnetometer available which can reliably measure differences down to 1 nT from point to point.

  • FLIM Upgrades for Nikon

    A1 / C1 / C2 - Becker & Hickl GmbH

    *bh FLIM Embedded in Nikon NIS-Elements Software*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Two HPM-100-40 GaAsP Hybrid Detectors*Excitation by bh ps Diode Lasers*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Excellent Timing Stability*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Detection Wavelength Range from 360 nm to 700 nm

  • Gas Detection

    Bacharach, Inc.

    Gas detectors designed to help comply with ASHRAE 15 and 34, EN 378, and CSA B52 are to protect someone from entering a mechanical room with refrigerant concentrations that could be harmful to their health. These protection levels are outlined in the safety standards to be about 1000ppm, 8-hour TWA depending on the type of refrigerant being used in the equipment. The alarm set points, location and number of detection points outlined in the safety standards are typically insufficient for finding the more common, smaller leaks that add up to large annual refrigerant emissions, decreased efficiency and overall safety.

  • Halo Automatic Testing System

    Fortress Technology Inc.

    Our revolutionary Halo system is an automatic metal detector testing device. It is designed to automatically test ferrous, non-ferrous and stainless steel samples on all Fortress metal detectors. Automatic testing saves time, money, labor, along with removing the risk of human error and work place injury at critical control points on a manufacturing line while complying with industry standards. The Halo system is ideal for applications where manual testing of a metal detector is made difficult due to access, position, access to the product flow, environmental conditions, etc.

  • On-line Crossbelt Analyzers

    CNA Range - Malvern Panalytical Ltd

    CNA online elemental analyzers are available in three models:*CNA³: This cross belt analyzer is designed for minerals applications that feature wide conveyor belts with deep loads and large material size. It is an open analyzer that is installed below the belt with both the neutron source and the detectors below. *CNA Pentos Cement: This cross belt analyzer is used primarily in cement and related industries. It is a closed analyzer that encircles the conveyor belt with the neutron source below the belt.*CNA Nickel: This cross belt analyzer offers real-time quality control for the nickel ore mining industry.

  • Rapid Automated Modular Microscope

    RAMM - Applied Scientific Instrumentation

    *Featuring automated high-speed XY stages, precision piezo & motorized Z focusing, and a wide range of scanning options.*Configurable with infinity-corrected optics, dichroic filter cubes, multi-wavelength excitation and emission filterwheels, shutters, and detectors including cameras and photomultipliers.*Auto-focus, focus stabilization, tracker, and robotic specimen loader available.*Arrangement provides a solid platform for high throughput screening, genetic sequencing, experimental research, and much more.*Designed for flexible cost-effective OEM development using high quality high MTBF components to reduce cost and increase customer satisfaction.

  • Services

    Dexter Research Center, Inc.

    By working in this way to help meet our customers’ needs, we have developed more than 30 models and over 900 finished goods. That gives you more detector choices, by far, than you will find from any other supplier. These provide the core products we customize for our customers. There’s no “one size fits all” here. With Dexter detectors, you will not need to compromise on noise, sensitivity, size, and durability. Instead, we have just the right component to help optimize performance for your sensing application.

  • Spectral Plotting Tool

    SearchLight™ - Semrock, Inc

    SearchLight is a free, online spectral plotting and analysis tool that allows fluorescence microscope users and optical instrument designers to model & evaluate the spectral performance of fluorophores, filter sets, light sources, and detectors as components of an overall system. Its intuitive user interface makes it easy to manipulate spectral component specifications and plot spectral results. The System Calculator allows the user to quantify system metrics including signal, SNR, and bleed through; as well as to compare various system configurations against each other. earchLight App available for iOS and Android

  • Stand Alone BERTS & SSG

    ML4039EML - multiLane SAL

    The ML4039EML is a fully featured 400G BERT that can be configured as a 4channel PAM4 56 GBaud or 4-channel NRZ 56 Gbps lanes. Also half rates around 28 GBd are supported. The transmitters Support all standard test patterns mandated by IEEE and OIF such as PRBS13Q, SSPRQ, PRBS31Q, etc… The user may also program the TX to output a user-defined pattern of 16384 UI maximum size The transmitters are single-ended with swing up to 1800 mVpp to enable driving EML-based optics. The error detectors are differential pairs with adaptive front end signal conditioning.