  • EBSD Detector

    Symmetry - Oxford Instruments plc

    Electron backscatter diffraction – is a powerful microanalysis technique that enables rigorous characterisation of the micro structural properties of crystalline materials. A high performance EBSD detector is critical for the effectiveness of the technique, influencing both speed and data quality. Symetry is Over 3000 indexed patterns per second (pps). Up to 30x faster than existing CCD-based detectors. Extreme sensitivity for low current and low kV analyses. Megapixel resolution for HR-EBSD applications. High resolution patterns (at least 156 x 128 pixels) at all speeds.

  • Meter Active Peak Reading Wattmeter

    HF/6 - Dishtronix Inc.

    Active peak reading wattmeter with simultaneously variable hold time on both the forward and reflected meter movements. This variable delay can be adjusted for quick action for high speed CW, or for longer periods more appropriate for the display of SSB and AM voice peaks. The peak detectors sport a new fast attack design capable of capturing quick pulses such as a single dit. Beautiful industrial design with tri color meter scale and brilliant LED illumination make the DWM series wattmeter a beautiful addition to any station.

  • Stealth Vent Tube Metal Detector

    Fortress Technology Inc.

    Stealth Vent Tube metal detectors are custom manufactured to integrate into any bottling application. The Stealth detects Vent Tube nozzles and metal contaminants in filled plastic or glass bottles of up to 3 liters/6.5 pints capacity. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous, non-ferrous and stainless steel contaminants. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.

  • StellarNet Spectrometer Models

    StellarNet Inc

    StellarNet miniature spectrometers are portable & compact fiber optic instruments for UV, VIS, and NIR measurements in the 190-2300nm range. The StellarNet series of miniature spectrometers is a step up in low cost instrument design, offering CCD 2048 & PDA 512/1024 detectors. The units are engineered to have no moving parts, no detector sockets, ruggedized aluminum enclosure, and an integrated A/D digitizer for unmatched durability and quality that out performs any instrument in its class. Numerous models offer standard or high resolution (HR) optics for selected spectral ranges.

  • Wearable Networked Gamma Neutron Detector

    D3S NET - Kromek Group plc

    The D3S NET radiation detector is a fast and accurate radioisotope identification device (RIID) for gamma isotope identification and neutron detection. The data collected by this radiation detector is not only shown to the user via the mobile phone app but also sent to a central control screen showing data from every other SIGMA enabled detector on the network. The D3S NET detector unit houses larger detectors that provide identification of isotopes in seconds, alerting the user and your command centre of gamma isotope source, dose and any neutron detection.

  • UV-VIS-NIR Spectrometer

    OES-Star - HORIBA, Ltd.

    Horiba’s OEM division, a major supplier of OES solutions, has developed a high end OES Spectrometer with a proprietary optical configuration for broad coverage (185-1050 nm) and high resolution. The OES-Star is available with a selection of three UV-VIS-NIR Back-Illuminated (B.I.) sensors, one TE-Cooled and two uncooled CCD detectors. This unique OES system features an optical design that provides a high peak symmetry across a very broad spectral range combined with high spectral resolution better than 1 nm, at an unmatched aperture of F/2.3.

  • Octal Digital Multi Channel Analyzer

    V1782 - CAEN S.p.A.

    The V1782 is the new CAEN Octal 32k digital MCA. Designed for high energy resolution semiconductor detector is perfectly suited for those application in which the number of input channels start becoming relevant such as when segmented HPGe, Clovers and silicon detectors are involved.The V1782 provides four steps of software selectable coarse gain and two possible jumper selectable dynamical ranges (0.2-0.4-0.8-1.6 Vpp and 1-2-4-8 Vpp).It is also compatible with Transitor reset preamplifier thanks to the jumper selectable 10 us AC coupling.

  • Ultrafast Joulemeter

    Gentec Electro Optics, Inc.

    Measure every pulse at up to 200 kHz with MACH 6. Measure with 12-bit digital accuracy and capture up to 4 million pulses in real time. Our MACH 6 Joulemeter is the only instrument in the world that performs at this speed, and with this precision. It is designed to support our full complement of fast energy probes that include Silicon, InGaAs and Pyroelectric Detectors. Measure from pJ to mJ and from 0.35 to 2.5 m. Using the M6-Si detector and the M5-UC-QED accessory, you can make relative measurements at 266 nm.

  • 2x8 QPSK Mixer

    Optoplex Corporation

    To be used for optical coherent detection such as DP-QPSK receivers, Optoplex’s ten-port 2x8 Coherent Mixer (aka QPSK mixer) combines the incoming signal with a local oscillator to generate eight light states in the complex-field space. The eight light output signals can then be coupled into four pairs of balanced detectors. The block diagram below shows the application of a 2x8 coherent mixer in a DP-QPSK receiver. Since the mixing process is data rate independent, the devices can be used for any data rate in applications such as 40Gb/s or 100Gb/s transmission systems.

  • Pixie Hybrid

    XIA LLC

    The Pixie Hybrid is a multichannel data acquisition system for fast radiation detectors in nuclear physics and other applications requiring coincident radiation detection, and provides the following advantages:*Compatible with PXI-Express Hybrid or PXI chassis*Sophisticated data acquisition*Advanced pulse shape analysis*Scalability; several modules can be combined into larger system

  • Plastic Fabrications Testing Equipment

    Buckleys Ltd.

    PD and PHD Pinhole/Holiday Detectors have an alarm circuit to alert the operator when a fault has been located and the required test voltage can be set on the unit's meter. Spark Testers provide an inexpensive means of testing but have no output voltage meter or audible alarm. However, they can test joints even if the backing is not connected.

  • Smoke Detector Tester

    Solo 365 - Detectortesters

    The fire industry’s most popular range of detector test equipment is about to get even better. Solo, the test equipment used world-wide to functionally test fire detectors has a new tester in its range – Solo 365. This exciting innovation provides fire safety professionals with an array of stand-out features which make for faster, simpler and cleaner functional testing of smoke detectors. Key features include automatic generation of smoke which ensures only the amount of smoke needed to activate the detector is produced – minimizing smoke wastage and eliminating the risk of detector contamination. In addition, Solo 365 is light in weight and has a slim-line design which allows easy access into tight spaces – making it possible to test detectors which are hard to access with other portable testers. In response to market feedback, Solo 365 features an LED torch which automatically illuminates when light levels drop, making for easy detector alignment and testing in dark environments. Smoke is generated via newly designed smoke cartridges which fit neatly into the rear of the tester. With no reliance on pressurised aerosol cans, the cartridges can be easily shipped and stored and are unaffected by new regulations, set for 2018, which will affect availability of some pressurised smoke aerosols.

  • Earth Magnetometer

    EM2 - Alpha Lab, Inc.

    The Earth Magnetometer Model EM2 measures small variations from location to location in the Earth magnetic field associated with buried magnetic masses. Unlike metal detectors, a magnetometer signal is not attenuated by rock, dirt, mud or water, so targets can be detected at great depth. (If D is the diameter of a mass of magnetizable material, the EM2 can detect it as deep as 40 times the diameter D, whether the mass is specifically magnetized or not.) It is the lightest weight and lowest cost magnetometer available which can reliably measure differences down to 1 nT from point to point.

  • FLIM Upgrades for Nikon

    A1 / C1 / C2 - Becker & Hickl GmbH

    *bh FLIM Embedded in Nikon NIS-Elements Software*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Two HPM-100-40 GaAsP Hybrid Detectors*Excitation by bh ps Diode Lasers*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Excellent Timing Stability*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Detection Wavelength Range from 360 nm to 700 nm

  • Gas Detection

    Bacharach, Inc.

    Gas detectors designed to help comply with ASHRAE 15 and 34, EN 378, and CSA B52 are to protect someone from entering a mechanical room with refrigerant concentrations that could be harmful to their health. These protection levels are outlined in the safety standards to be about 1000ppm, 8-hour TWA depending on the type of refrigerant being used in the equipment. The alarm set points, location and number of detection points outlined in the safety standards are typically insufficient for finding the more common, smaller leaks that add up to large annual refrigerant emissions, decreased efficiency and overall safety.