Detectors

register the presence of a stimuli.

See Also: Metal Detectors, Particle Detectors, Sensors, Charge Sensitive Preamplifiers


Showing product results. 436 - 450 of 678 products found.

  • Confocal FLIM for Macroscopic Objects

    DCS-120 Macro - Becker & Hickl GmbH

    *FLIM of Macroscopic Objects*Scan Field Up to 15 mm Diameter*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*One or Two BDL-SMN or BDS-SM ps Diode Lasers*Tuneable Excitation by Super-Continuum Laser with AOTF*Two Fully Parallel Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Wideband Version, Compatible with Tuneable Lasers*Electronic Pinhole Alignment*Optional: Spatial Mosaic FLIM via Motorized Sample Stage

  • Portable Vehicle Weighing System

    RWP-700A - Kyowa Instruments

    RWP-700A is a portable system to weigh and manage truck loads. It consists of the detectors that detect the truck weight by weighing the load of each wheel on the platform and the indicator that indicates, records and prints out the weighing result.For measurement, place detectors in parallel on a flat pavement surface, put front wheels on the respective detector platforms at the center and press the MEASURE key. Repeat the same for rear wheels. Pressing the PRINT key prints out the weighing result. Different from a stationary truck scale that weighs a truck with the whole truck body put on the detector, the portable system is allowed to be carried anywhere for measurement not only in factories but also in construction fields where the road surface is solid.

  • Fuel Density Meter

    FD-5110 - Ono Sokki

    By connecting with the FM-3100 Digital Flow Meter, the FD-5110 Fuel Density Meter can measure temperature and density data in real time. In addition, the FP series Volumetric Flow Detectors with wide range ability and the FD-5110 are the best choice for achieving the accurate mass flow measurement.

  • 64 Channel 16 bit 125 MS/s Digitizer

    V2745 - CAEN S.p.A.

    The V2745 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.

  • 64 Channel 16 bit 125 MS/s Digitizer

    V2740 - CAEN S.p.A.

    The V2740 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64 form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.

  • 64 Channel 16 bit 125 MS/s Digitizer

    VX2745 - CAEN S.p.A.

    The VX2745 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.

  • 64 Channel 16 bit 125 MS/s Digitizer

    VX2740 - CAEN S.p.A.

    The VX2740 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.

  • Liquid Level Switch

    CL-10GH - Automation Products, Inc.

    The Dynatrol® CL-10GH Liquid Level Detector and EC-501A(G) Control Unit is used for high, intermediate or low point level detection of liquids and slurries. A unique vibrating principle permits design and operation features not available with other types of liquid level detectors.

  • Photodetectors

    Menlo Systems Gmbh

    Detection of weak light pulses on the few-photon level is crucial for many applications. The Menlo Systems' detector portfolio includes PIN photodiodes with low noise RF amplifiers, ultrafast avalanche photodetectors with integrated high voltage supplies, and detectors based on homo- and heterodyne detection.

  • Illuminance Meters

    Konica Minolta Sensing, Inc.

    Illuminance meter products are single element detectors that measure photometric brightness falling upon a surface. It is measured in footcandles or in lux. The Konica Minolta illuminance meters measure the amount of light that strikes a surface. These instruments display illuminance in either lux or foot-candles and they are lightweight, compact and portable.

  • X-ray Analytical Microscope (Micro-XRF)

    XGT-9000 - HORIBA, Ltd.

    - <15µm probe size with ultra-high intensity without compromising sensitivity or spatial resolution. - High resolution cameras and multiple illumination modes to help capture images.- Dual types of detectors for transmission and fluorescent X-rays.- Detectable element range down to carbon with a light element detector.

  • *Laser Pyroelectric Energy Sensors

    Ophir Photonics

    Pyroelectric sensors for measuring repetitively pulsed energy at up to 25 kHz. These sensors use a pyroelectric crystal that generates an electric charge proportional to the heat absorbed. The response time of the pyroelectric sensor depends on the time it takes for the heat to enter the crystal and heat it up. For metallic type pyro detectors, this time is tens of μs and thus the metallic type can run at a high repetition rate. For the BF and BB type, the response time is milliseconds with a correspondingly lower repetition rate. Ophir pyroelectric detectors have unique and proprietary circuitry that allow them to measure long pulses as well as short pulses and work at a high duty cycle, i.e. where the pulse width is as much as 30% of the total cycle time.

  • Electrostatic Capacitance-Type Non-Contact Thickness Meter

    CL-5610 series - Ono Sokki

    The CL-5610/5610S is used to perform non-contact thickness measurement of objects under measurement including conductors, semiconductors and insulators in combination with the new-developed VE series capacitance type gap detector. The CL-5610/5610S can be connected up to 2 gap detectors and also used as 2-ch displacement meter.

  • Heat Detector Testing

    Solo 461 - Detectortesters

    Functional checking of heat detectors, with a genuine heat source, is now required by major national standards around the world. Testing with heat sources not designed for the purpose can be both dangerous and damaging. The Solo range of heat detector testing equipment, designed specifically for the purpose, provides a genuine professional’s solution.

  • Insertion Loss Testing

    OptoTest Corp.

    Measures insertion loss on simplex optical fiber cables by using continuous wave (CW) sources in conjunction with a high quality optical power meter. With a customizable selection of sources, fiber types, detectors, and front panel connectors, the OP815 is the ideal solution for measuring IL on any simplex cable.