Showing results: 121 - 135 of 5316 items found.
-
-
SE-05 -
KILTER ELECTRONIC CO.,LTD
Digital clamp meter designed for leakage current measurement. Least affected by external stray magnetic field. Four AC current ranges: 400mA/4A/40A/200A
-
Osborne Transformer Corp.
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
PeakTech Prüf- und Messtechnik GmbH
Are ideal for current measurement in electrical systems and control cabinets, since only single wires are guided through the clamp jaws for contact-free current measurement and no electrical connections have to be disconnected. This method also enables measurements of very high currents, which would overload any standard multimeter if connected directly.
-
7610B -
Peaceful Thriving Enterprise Co Ltd
This is a stable, low power consumption, and high accuracy 3 1/2 digits (2000 counts) leaking current tester for automobile. Leaking current for automobile is generally as small as milliamps, which is hard to measure by clamp meter. By plug this meter with the fuse box, user is able to measure leaking current as small as 1 mA.
-
IVC-222HPII -
Martel Calibrators
The Voltage Current Calibrator is a general purpose current and voltage source that can be used in engineering, manufacturing, test, and process control application.Four ranges: 200 mV, 2V, 20V, and 24 mA
-
NUL-202 -
Neulog
This sensor can be used to measure the current in parallel or series branches of low voltage AC and DC circuits and also to investigate the dependence of the current flow through components on the voltage across them.
-
iDVM 333 -
Redfish Instruments, Inc.
The iDVM 333 AC Current Transducer plugs into the iDVM 510 multimeter and measures current (as AC millivolts) with no need to break the circuit. Special Introductory Price: $52.50FeaturesTransformer jaws that detect AC current flowing through a conductorSelectable sensitivity between 1mV/A and 10mV/AHand Guard to protect your hand for safetyLarge, easy-to-operate trigger opens the transformer jaws
-
TK-4802 -
Gemini Data Loggers Ltd.
Supplied with an input cable, this logger can measure current between 0 and 20mA DC and can be connected to many industry standard devices, such as CO2 sensors and current clamps, enabling the logging of a wide range of process parameters.
-
PRODIGIT Electronics Co, Ltd.
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.
-
AEMC Instruments
Comprehensive line of clamp-on current probes covers the entire spectrum of applications, from electrical panels to substations. AEMC Current Probes measure current without interrupting the circuit under test and extend the measuring capabilities of DMMs, recorders, power meters, and loggers. The numerous jaw sizes are designed to accommodate a wide variety of conductor diameters and ranges. Available for AC or DC measurements.
-
ORTEC
The ORTEC Model 439 Digital Current Integrator was designed to accurately measure dc currents or the average value of pulse currents such as produced by accelerator beams. It digitizes the input current by producing an output pulse for specific values of input charge. A front-panel switch permit the selection of three different amounts of charge (10–10, 10–8 or 10–6 coulomb) required to produce an output pulse. The instrument has a digitizing rate from 0 to 10 kHz to provide wide dynamic range on each setting and high-resolution readout without meter interpolation.
-
CTH -
Powertek LLC
The CTH sensors convert dc current to an isolated voltage output, the CTHR sensors convert ac current to a dc output signal proportional to the Arms. All popular process control voltage and current loop outputs are available. Through hole or split core options mean that connection is non-intrusive and straightforward. The available input range of the CTH sensors is any value from 5A to 6000Adc.
-
IBA Dosimetry GmbH
Invasive and non-invasive measurements of the tube current with MagicMaX Multimeters.
-
Renesas Electronics Corp.
Low input current and transistor output photocouplers (optocouplers) are optically coupled isolators containing a GaAs infrared light emitting diode and an NPN silicon phototransistor. This type features a fast response while operating on a low input current.