-
product
PXI 2 Amp MUX, Single 8-Channel 4-Pole
40-635-103
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1E-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Sources And Supplies
Source and measure voltage, current, and resistance using source measure unit instruments.
-
product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1P-2-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Multi Current-Mode-Coupler
Sy629PMC-M-CMC
The Sy629PMC-M-CMC module allows ARINC-629 terminals to communicate directly without the need for an ARINC-629 bus Cable and conventional Current Mode Couplers.
-
product
Socket Tester
1945
Peaceful Thriving Enterprise Co Ltd
This is a portable 220VAC socket tester to inspect the wiring conditions. The tester also features current variation for simulation of different leaking current. With the current variation, technician is able to test the condition of Ground Fault Circuit Interrupter (GFCI) / Residual Current Device (RCD) easily.
-
product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2C30-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Clamp Meter
KT-3500
• Non - intrusive AC and DC current measurement• 10mA resolution• Average responding, RMS calibrated• Auto ranging /Auto zeroing• Data Hold • Low battery indicator• Auto Power OffMeasuring Range: 0 - 500A DC or ACAuto ranging : 50A/500AResolution: 10mA in 50A range, 100 mA in 500A rangeBasic Accuracy: ±1.3% rdg ±5 digitsTemperature coefficient: ±0.05% of rdg /°CFrequency range: DC in DC: 40 HZ to 400 HZ in ACOverload capacity: 500 ADielectric strength: 3.7 KV RMS.50 Hz 60s(EN61010-2-032 Cat III...show more -
product
Electronic DC Load, 80V, 80A, 400W With/without Remote Interfaces
LD400 Series
Versatile solution for testing dc power sourcesConstant current, resistance, conductance, voltage and power modesWide voltage and current range, 0 to 80V and 0 to 80A400 watts continuous dissipation at 28°C (360W at 40°C)600 watts short-term dissipation (up to 60 seconds)Low minimum operating voltage of <1V at 40AHigh resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingH...show more -
product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-2R1S
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1P-8-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Contact Resistance Meter
CRM-100
Contact Resistance Meter CRM-100 is capable of providing test current up to 100A subject to the load resistance and supply voltage. It can be used to test circuit breaker contacts, switch contacts, busbar joints or other applications where high current is needed.
-
product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25I15-10
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
FC Impedance Meters
designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.
-
product
Test Setup For Air Conditioner
SCR ELEKTRONIKS have developed TESTING SET UP FOR SINGLE PHASE / THREE PHASE MOTOR for carrying out Performance Test, Earth Contact Resistance Test, High Voltage Test, Megger Test and Leakage Current Test. It consists of Voltmeters, Ammeters and Wattmeters for observing the values of different parameters. OK / NOT OK lamps are also provided to display the results of Earth Contact Resistance Test, HV test, Megger Test, Leakage Current Test. All tests are provided with tripping cut off concept.
-
product
PXI 2A Multiplexer, 4-Bank, 8-Channel 4-Pole
40-614-008
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
Checking the Geometry and the Placement of the Weld
Based on the real geometric three-dimensional profile of the weld (groove) on the outside of a large diameter pipe, determine the offset of the center of the weld (groove) from the weld line. Provide continuous output of results through the RS-232 interface to the welding process control system. Provide a graphical picture of the current profile, the values of the specified and calculated geometric parameters to the operator.
-
product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2TB-8
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Serrated, Multiple Point Waffle, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0H
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Digital Indicators
NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. The NOSHOK Attachable Loop Powered Digital Indicator can easily be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. NOSHOK also offers a dual display model that accepts a wide variety of input signals including thermocouples or RTDs, current, voltage, resistance and process signals. Plug-in option cards are available on several models for field upgrading.
-
product
AC Power Analyzers
Measure voltage, current and power on 4 channels: DC, 1-phase AC or 3-phase ACMake more accurate power measurements: 0.05% at 50/60 HzMeasure current directly: internal shunts to 50 Arms, or with external probes or transducersAddress multiple test scenarios with isolated inputs
-
product
Leakage Test
Leakage current and discharge current depend on the insulation of the device. The measurement simulates various fault situations that could occur during operation. The test determines whether the measured current is within the permissible limits and poses no danger to the user in case of a fault.
-
product
5-Watt Broadband Transmitter
Loc3 5W
The 5-Watt broadband transmitter has selectable induction and direct connection frequencies from 98Hz to 200kHz, SD mode (Signal Direction), fault find and true resistance measurement up to 1 Mohm. The two inch by one-inch dot matrix display with LED backlight shows output current, connection type, volts, resistance, frequency, volume, battery condition and high voltage warnings.
-
product
High-Voltage Supply
Model 605A
The Trek Model 605A is a high-voltage reference supply designed to provide precise control of output voltages in the range of 0 to +1 kV DC or 0 to -1 kV DC with an output current range of 0 to 1 mA DC.
-
product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-1I15-6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
DC Blocking L-Band Splitter Combiner
PD5940
INSTOCK Wireless Components, Inc
PD5940 is an IP67 outdoor, weather resistant, DC blocking, four way, RF broadband, 50 ohm, power divider, power combiner furnished with TNC coaxial connectors. The passive Wilkinson design passes RF, 10 MHz and DC current through one port, typically for powering an active antenna, with the other ports blocking DC. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoH...show more -
product
PicoBuck LED Driver
The PicoBuck LED Driver is an economical and easy to use driver that will allow you to control and blend three different LEDs on three different channels. By default, each channel is driven at 330mA; that current can be reduced by either presenting an analog voltage or a PWM signal to the board. Version 12 of the board adds a solderable jumper that can be closed to increase the maximum current to 660mA. The new voltage regulator also increased the voltage rating on the various components on the board, allowing it to be used up to the full 36V rating of the AL8860 part.
-
product
ABex Rear Module for Utility Power Supply
ABex RM-UTILITY
The ABex RM -Utility is a rear module for the ABex-System. It provides 5 galvanically isolated fixed supply voltages for TUA (Test Unit Adapter) and cabinet supply. It features an over current protection and a software-controlled power enable.
-
product
Current Transformers
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osbor...show more -
product
Handheld Circuit Breaker And Timer Analyser
CAT-H Series
The operation of the breaker can be initiated in different ways (e.g. from a control room, by a local breaker or externally by a test device) depending on the test conditions. Various time measurement triggers are available to record a measurement under a different test condition:*Coil control channel*Continuous current clamping channel*DC voltage channel