product
LOADED BOARD TEST PROBES
SERIES-70
ElectricalMAXIMUM CURRENT: 5 amps continuousat working travel, non-inductiveRESISTANCE: At 35mA test current70 18 mOhms mean73 60 mOhms mean74 40 mOhms meanMaterials and FinishesPLUNGER: Heat treated beryllium copperor steel hardened to 55-60RC70 24Kt gold plated over nickel73 24Kt gold plated over nickel74 Rhodium plated over nickelBARREL: Nickel silver70 24Kt gold plated ID and OD over nickel73 No Finish74 24Kt gold plated ID and OD over nickel
-
product
Electrical Safety Test Solutions
Hipot Analyzers with 500VA output rating can be used to test and analyze the withstand voltage of high power and leakage current for the products like motor stators and rotors with high parasitic capacitance. Corona detection can be used for turn-to-turn or turn-to-ground test to avoid winding insulation failure from corona discharge.
-
product
Serial Production Mark Quality Control
The control system is based on the Sick IVC smart camera, which not only captures, but also processes the image. After training on the font samples, the system practically does not require the operator's attention in addition to setting the current marking for control. The character set can be specified by the operator or transmitted via the interface from the printer or from the enterprise information system.The camera software works autonomously: it loads all settings from the camera's permane...show more -
product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
product
Autoranging System DC Power Supply, 750 V, 60 A, 15000 W, 208 VAC
N8935A
The Keysight N8900 Series is a family of 5 kW, 10 kW, and 15 kW autoranging, single-output power supplies available in 14 different voltage, current, and power combinations and either 208 VAC or 400 VAC (28 total models).
-
product
DataNet Wireless Data Loggers
The DataNet wireless system is a data acquisition solution developed for 24/7 real-time monitoring for mission critical organizations. Boasting a variety of wireless data logger models using ZigBee RF technology, the DataNet solution is capable of measuring parameters such as temperature, relative humidity, voltage, current, or frequency. Choose from DataNet models offering up to 6 inputs or the more cost-effective single or dual input Mini DataNet range, depending on your application requiremen...show more -
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2X
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Voltage, Continuity, and Current Tester
FLIR VT8-Series
The FLIR VT8-Series are high-quality voltage, continuity, and current testers. They feature an optimized, open-jaw design that can fit into tight spaces and reliably measure large-diameter cables. The VT8-600 carries a CAT III-600 V/CAT IV-300 V safety rating and a 100 A/600 V measuring range, while the VT8-1000 carries a CAT III-1000 V/CAT IV-600 V safety rating and a 200 A/1000 V measuring range. Extensive measurement features make the VT8-Series versatile tools – just one meter can get the job done.
-
product
Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit
72-1015 CAL DU
The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro re...show more -
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1J-10-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Three Phase Secondary Current Injection Test Set
TEST-330B
Beijing GFUVE Electronics Co.,Ltd.
Three phase secondary current injection test set is testing relay set, protective device, instruments, output ac dc current and voltage source, embedded Window XP system.
-
product
High 1.73 (49.00) - 8.00 (127.00) High Performance Lead Free Probe
LFRE-1L18-8
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
1000 Amp AC/DC Inductive Amp Clamp
6043
• A great tool for accurate measurement of current sources up to 1000 amps• Use with most digital multi-meters• 1mV/Amp output guarantees easy reading on your meter• Ideal for checking starter draw, alternator output or parasitic battery drain testing• Design allows accurate current readings without breaking the circuit• Low battery indication – auto power-off• Switch settings OFF/200A/1000A• Large jaw opening, 2.2″ and large jaw space, 2.2″ x 2.75″• Imported
-
product
Circuit Breaker Identifiers
188 FFF
Standard Electric Works Co., Ltd
● The 188FFF doesn't have the function of the sensitivity adjustment. If the customers need the sensitivity adjustment function, plase refer to other models.● The 188FFF is a Fuse and Fault Finder which comprises of two parts : The Receiver and the Transmitter.● The Transmitter, draws a current from the mains supply circuit to which it is connected to. The Signal● Current from the Tx is at about 10kHz. The Transmitter is powered by the mains and requires no batteries.● The 10kHz signal...show more -
product
Dual Display Digital Pressure Sensor [For Gas]
DP-100L
Panasonic Industrial Devices Sales Company of America
Panasonic’s compact DP-100L Pressure Sensor with IO-Link features an improved digital display that offers increased clarity and a wider viewing angle. Thanks to a redesign of its circuitry, the low-power-consumption DP-100L Series requires 14% less power during normal operation and when operating in ECO / FULL mode the display is completely shut off for an increased power savings of up to 50% compared to normal operation. The current value and the threshold value can be checked at the same time, so the threshold value can be set and checked smoothly without switching to another screen mode.
-
product
Test Bench For Circuit Breaker
SCR ELEKTRONIKS have developed Test Bench for Circuit Breaker to test 2, 5 & 10 at a time. Panel is provided with constant DC current source.
-
product
Power Supply, 300 V, 11 A, 3300 W
N8741A
Keysight's basic DC power supplies offer essential features for a tight budget. The Keysight N8741A is a 300 V, 11 A, 3300 W, single output power supply in a small 2U package. It offers flexible AC input options, analog/resistance control of output voltage and current, as well as parallel and series connection of multiple supplies to achieve more output current or voltage.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T24-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Solar Array Simulator
Among other things, solar array simulators are required for testing satellite power supplies. An SAS (Solar Array Simulator), consisting of an interconnection of several Solar Array Simulator modules, maps the solar panels and displays the individual strings connected in parallel. Optionally, the individual SAS modules are monitored by a Second Level Protection, so that the test object is not damaged in case of errors with the voltage sources. Additional circuitry is implemented via project-spec...show more -
product
PXI 32 Chan I/O Parallel I/P Prog Threshold
40-412-111
A 32-channel Digital I/O module with high output voltage and currentcapability and a dual variable threshold input. Each of the 32 channel outputs can be used to drive the output high or low usinga high current capacity drive capable of sourcing 0.4A from the high side or 0.5Asink on the low side for each channel. The module is available in two versions witheither serial or parallel capture of the input levels.
-
product
C Series Universal Analog Input Module
The C Series Universal Analog Input Module helps you perform multi-purpose measurements. This module includes built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. You also can choose options to measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors.The C Series Uni...show more -
product
PXI General Purpose 2A Relay Module 16xSPDT, 50 D-sub
40-131-001
These low cost, general purpose electromechanical relay cards are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 50 pin D-Type connector plug.
-
product
Leakage Current Tester
Test Voltage : - 1V to 500V DC settableAccuracy : ± 1% of set Value ± 1digitLeakage Current : - Accuracy - ± 0.5% ± 1digitDigital Model – 19.99μA / 199.9 μA / 1.999mA / 19.99mAAnalog Model - 10μA /25μA/100 μA/1mA/2.5mA/10mASeparate Indication for Charge / Measure and Discharge modeAvailable in Digital Version Also
-
product
DC Power Supply
PW-4032
*High Resolution Read out: 10mV/1mA *10 Turn VR for Voltage and Current Setting *Dual output: 0~30V/0~3A;5V Fixed/0~3A *4 Digits, 2 Display
-
product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25I35-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Dc Watt Meter For DC Current Measuring
IM1401
Our product range includes a wide range of dc watt meter for dc current measuring.
-
product
311 HP Eddy Current Chassis Dynamometer
CM-51SR-EC
Weight Capacity: 25,000 lb (11,340 kg) per axleRoll Brakes: pneumatically-actuated discShipping Weight: 5,100 lb (2,312 kg)Capacity: 311 hp at 45 mph (232 kW at 72 kph)Rolls: 20 by 36 in. (508 by 915 mm) long, 2 fixedPit Required Depth: 25 in. (635 mm)
-
product
Wet Leakage Current Test
King Design Industrial Co., Ltd.
The outdoor solar module will endure the erosion of rain, fog, snow and sandstorm. To make sure that solar module will not wet leakage current accident and tolerate huge load pressure in such harsh conditions, we adopt wet leakage current to simulate the above weather conditions.
-
product
120 A Manual Pulse Width Extender
TLP-12012A6
High Power Pulse Instruments GmbH
- Pulse width extender for the high current TLP/HMM test system TLP-12010A and TLP-12010C- 6 manual selectable pulse width: 5, 10, 50, 100, 200 and 500 ns- High pulse output current up to ±120 A- High performance and high quality components
-
product
Capacitor Leakage Current Meter
DU2316/2317
Delta United Instrument Co., Ltd.
Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed