Filter Results By:

Products

Applications

Manufacturers

Calibrators

ascertain instrument graduation deviation and rectify to precision known values.

See Also: Calibration, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 151 - 158 of 158 items found.

  • Noise Dose Meters

    PCE Instruments

    Here you will find a full range with an industrial standard noise dose meter to suit every requirement. With the portable noise dose meter you can carry out measurements quickly to gain control of a situation or to set the device to take timed measurements. The noise dose meter is important for all industries, especially by using it as a mobile device which is able to assess office stress levels or street noise levels.Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10pm in excess of what local laws permit. We, of course, can assess which noise dose meter you require in relation to the issue you have and the relating laws. We also have microphone extension cords, tripods, calibrators and calibration certificates for most models of noise dose meter.

  • Trace-Level Photometric Ozone Calibrator

    Model T703U - Teledyne Advanced Pollution Instrumentation

    The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.

  • Trace-Level Dilution Calibrator

    Model T700U - Teledyne Advanced Pollution Instrumentation

    The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.

  • Noise Meters

    PCE Instruments

    Here you will find a full range with an industrial standard noise meter / sound meter to suit every requirement. With the portable noise meter you can carry out measurements quickly to gain control of a situation or to set the sound meter to take timed measurements. The noise meter is important for all industries, especially by using it as a mobile noise meter which is able to assess office stress levels or street noise levels. Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10 pm in excess of what local laws permit. A noise meter / sound meter will help here.We can assess which noise meter or sound meter you require in relation to the issue you have and the relating laws (requirements regarding a sound meter and a sound meter’s usage vary depending on the country). We also have noise meter microphone extension cords, tripods, sound meter calibrators and calibration certificates for most noise meter models.

  • Measurement and Analytics Solutions

    LXinstruments GmbH

    Based on our OTP² system platform, we were able to implement a family of scalable test systems which is based on a common systems architecture, e. g. for products in the area of chemical analytics measurement. We not only implemented a universal, extremely comprehensive test system, but also a series of compact systems for benchtop placement which are fully compatible with the larger, universal system. Our specialized self-test adapters and test software enable fast verification of the test systems as well as partly automated calibration by the customer.Our systems are also used in electrical measurement applications, e. g. for calibrating analog input assemblies for PLC technology. For this purpose, specialized calibrators are integrated into the system; they provide traceable calibration of the relevant stimulus signals.

  • Zero Air System

    Model T701 - Teledyne Advanced Pollution Instrumentation

    The T701 adds Modbus TCP/IP connectivity to the proven reliability and performance of our zero air systems. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature, and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and less power consumption. The user can also remotely start instrument warm-up prior to arrival at the site.The T701 is a fully self-contained source of clean, dry air for dilution calibrators. It can also be used to create purge air for permeation tube ovens or burner air for FID analyzers. The T701 includes a dewpoint sensor, an oil and diaphragm-free pump, and scrubbers to remove SO2, NO, NO2, O3, H2S, and NH3. Optional high performance scrubbers are available to remove CO and Hydrocarbons.

  • High Performance Zero Air System

    Model T701H - Teledyne Advanced Pollution Instrumentation

    The T701H adds Modbus TCP/IP connectivity to the proven reliability and performance of our high purity zero air system. This allows remote monitoring of key instrument functions including dewpoint status, scrubber temperature, box temperature and output pressure. Additionally, this digital access provides the ability to remotely disable the internal pump, allowing longer service intervals and less power consumption. The user can also remotely start instrument warm-up prior to arrival at the site.The T701H is a fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with highly sensitive analyzers in ambient background and trace level applications. The T701H includes a dewpoint sensor, an oil and diaphragm-free pump, scrubbers to remove SO2, NO, NO2, O3, H2S and NH3, plus high performance scrubbers to remove CO and Hydrocarbons.

  • Proprietary Software

    WinFT - D&P Instruments

    WinFT is our proprietary software which makes D&P instruments so functional and easy to winft1_largeuse. Based on the Windows operating system, this software provides simple and intuitive control of the instrument. All of the usual File functions are available, as well as controls over instrument settings such as resolution, apodization, zero-fill and number of coadds. Display options enable the user to display interferograms, spectra or both, as well as to adjust plot scales and units. Onboard math processing allows for real-time calculation of ratio, difference, and absorbance, and when using our calibrated hot-cold blackbody calibrators, the ability to measure calibrated radiance. Further, WinFT offers the ability to measure sample temperature in the radiance function by matching a Planck to the calibrated radiance. With the gold diffuse plate, the software can also compute and display absolute emissivity of samples. Our software also enables exporting of data files, now made even easier with our USB and LAN connections. In addition, the software has been designed to be easily run using the keyboard function keys and single letter commands, making the use of a mouse in the field optionalas well as minimizing key strokes when taking measurements in the field.

Get Help