Showing results: 556 - 570 of 1915 items found.
-
Fluke Calibration
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
Beddrock BACx -
Bedrock Audio
The Bedrock BAC1 and BAC2 acoustic calibrators are used to accurately verify (and if neccesary adjust) the level calibration of your Bedrock acoustic measuring instruments. We recommend the BAC1 for the Bedrock SM90 class 1 instrument, and the BAC2 (which complies with class 2) for the Bedrock SM30 and SM90. Each calibrator comes with an individual calibration certificate.
-
10772A -
Keysight Technologies
The Keysight 10772A Turning Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror is used in the 5530 Laser Calibration System for applications such as machine tool calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10772A.
-
SY8320E -
Hong Kong Songyang Industrial Ltd.
Close-link and ordinary calibration both can be used, ordinary calibration can be used to test single/three phase active and reactive energy meter (up to 0.5 class),close-link calibration can be used to test single/three phase active and reactive energy meter (up to 1 class)
-
LAQUA PD220 -
HORIBA, Ltd.
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation- 0.01 mg/L or 0.1% DO resolution- Compensates salinity, temperature, and atmospheric pressure - Up to 2 DO calibration points - With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting the meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
MC-1000 -
Martel Calibrators
The MC-1000 Process Calibrator provides high accuracy calibration, common DMM functions including read and source thermocouples, RTDs, Ohms, current, pressure, frequency and test continuity. This single calibration instrument will calibrate virtually any process device including: read and source thermocouples, RTDs, Ohms, Voltage, Current, Frequency, Pressure, and test continuity.
-
Fluke Calibration
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
211 -
Elcometer Limited
This is one of the most popular mechanical coating thickness gauges in the world.Factory calibrated - with user calibration adjustmentFoils supplied to check calibration on siteIdeal for cold surfaces and underwater useSmall and portable with an accuracy ±5%The “V” grooved base, ideal for pipeline inspectionAvailable in either Metric or Imperial versions, the Elcometer 211 measures coatings up to 6mm (250mils)
-
Fluke Calibration
Fluke Calibration offers molbloc/molbox gas flow calibration systems to calibrate flow meters and controllers over a very wide range of flows. The systems are fast, precise and transportable and can be fully automated using COMPASS for Flow software. molblocs, which are the heart of the measurement system, are mechanically stable, gravimetrically calibrated laminar flow and sonic nozzle elements.
-
10773A -
Keysight Technologies
The Keysight 10773A Flatness Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror, used in the 5530 Laser Calibration System, measures flatness in applications such as surface plate calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10773A.
-
10777A -
Keysight Technologies
The Keysight 10777A Optical Square, used with Keysight straightness measurement optics, adds squareness measurement capability to the Keysight5530 Laser Calibration System. The optical square measures the squareness of axes during laser calibration of a machine tool. The Keysight 10777A uses two accurately-aligned mirrors to direct an output beam at precisely 90 degrees to an input beam.
-
Tinsley Precision Instruments
A range of units to cover the requirements of development laboratories and calibration and test departments. High resistance instruments provide reliable calibration of insulation testers.
-
-
CSE Co.,Ltd
* Resistor Calibration Substrate * Mili Ohm ~ Giga Ohm * Wafer type size 6, 8, 12 inch.
-
Schwarzbeck Mess Elektronik
Van der Hoofden test head with protection network and individual calibration of the network acc. IEC62493 or VDE 0848-493.