Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 1711 - 1725 of 1906 items found.

  • 3 Wire (Digital) Earth Resistance Tester

    ST-1520 - Standard Electric Works Co., Ltd

    ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Auto power off function.● The timer operates automatically for about three to five minutes when the "PUSH BUTTON SWITCH" and "TIMER ON BUTTON" are pressed together. This will keep test "ON" for the duration of the timer.● Timer for test function (count 3-5 minutes).● Battery operated.● Data hold function.● Small and light weight.● Calibration performed with supplied test leads.

  • sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    781210-01 - NI

    Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • Waterproof ExStik® Fluoride Meter

    Extech FL700 - Extech Instruments Corporation

    Specifically designed for the quick and accurate measurement of fluoride ions in drinking water and other aqueous samples, the ExStik FL700 incorporates a sensing electrode, measuring electronics, and display in one convenient package, making this unit ideal for field or laboratory testing. The FL700 is capable of direct reading of total fluoride from 9.99 ppm or mg/L down to 0.1ppm, and the meter provides automatic temperature compensation (±10 degrees C of calibration temperature). Complete with electrode, TISAB reagent tablets, sensor cap, four 3V button batteries, and 48" (1.2m) neckstrap.

  • Moisture Meters

    PCE Instruments

    Moisture can be found in any material. Even materials considered to be dry have a minor amount of moisture. An imbalance of moisture, whether it be excessive moisture or too little moisture, can cause problems ranging from undesired mold and bacteria growth to cracks and defects. To avoid a moisture imbalance, it is essential to monitor moisture content with a moisture meter that returns accurate and reliable measuring results. A moisture meter can measure the moisture content of everything from the air (relative humidity) to construction and building materials (concrete, wood) to biomass and agricultural products (hay, straw, grain, corn, beans, pellets) to solid waste (pulp, slurry) and beyond. Many moisture meter devices can also measure temperature. The moisture measurement range of each moisture meter varies depending on the model. Some moisture meter products take moisture measurements, store the moisture measurement data to an internal memory or SD cad, and allow the stored moisture measurement data to be transferred to a computer for detailed analysis by means of an evaluation software. PCE Instruments' moisture meter products come factory calibrated. ISO calibration certificates are available optionally for purchase as accessories to most moisture meter models. An ISO calibration certificate may be important to your company in meeting specific quality standards.

  • Digital Surface Resistance Test Kit

    PAS-853BRM - Prostat Corporation

    - Surface Resistance Kit from 0.01 ohm to 9.99x1012 ohms- Nominal Full Range Tolerance Averages <±5%- Fully Automatic Resistance Range, Test Voltage and Electrification Period control- Determines if a surface is Dissipative, Conductive, or Insulative- Measures resistance point-to-point(Rtt) and point-to-ground (Rtg)- Measures resistance of Static Control Floors, ESD Work Surfaces and Packaging Material- Conforms to all ESD Association Standards for Resistive Characterization- Includes 2 each Conductive Rubber Electrodes- Packaged in a hard shell Carrying Case- Certificate of Calibration Traceable to NIST included

  • 4 2/3 Strain Gage Meter

    CS2-SG - Chuan Sheng Electronics Co., Ltd.

    CS2-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS-485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.

  • 4 2/3 Strain Gage Meter (1/32 DIN)

    CS3-SG - Chuan Sheng Electronics Co., Ltd.

    CS3-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.They are also building in 2 Relay outputs, 1 External Control Input, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.

  • Industrial 4-20mA Driver

    Analog Devices Inc.

    Analog Devices portfolio of leading industrial d/a converters and drivers addresses the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.

  • Ultra Low Noise, Rubidium Frequency Standard.

    A10-M - Quartzlock (UK) Ltd.

    Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.

  • Carbon Dioxide Quality Control System

    CDQC - Teledyne Analytical Instruments

    Teledyne’s Carbon Dioxide Quality Control (CDQC) system offers an integrated package to continuously monitor impurities in carbon dioxide (CO2). The plug-and-play design allows for the user to select only the gases and features of interest to maximize cost benefit and space.Front door viewing windows allow for view of all analyzer displays, flow and pressure settings. Stainless steel tube fitting connections and NPT or metric electrical ports as required are conveniently located in a central location for ease of access. Sample conditioning, utility gas provisions and integral calibration gas solenoid valves are standard.

  • Gas & Flame Detection System

    Syntel - Teledyne Gas & Flame Detection

    Syntel is an addressable loop system suitable for use in zone 1 and 2 hazardous areas. The complete addressable loo is fault tolerant operating normally with a short or open circuit. Syntel does not have a CPU, so there is no common failure point. It includes a standard OPC interface and can also be supplied by Modbus allowing easy integration with third party systems.Syntel stores alarm and calibration information in distributed non-volatile memory, hence there is no reliance on a centralized system.Syntel is ideal for installations where there is the possibility for future expansion. The system architecture allows very low cost expansion as cable runs to a central location are not needed.

  • High Temperature Un-Cooled Extensometers (700 C)

    Model 7642 - Jinan Testing Equipment IE Corporation

    These extensometers use a high-temperature capacitive sensor and do not require any cooling. They will operate up to the maximum temperature limit of most environmental chambers used in materials testing. The Model 7642 is ideal for testing composites, metals and high temperature polymers in tensile, compression or cyclic testing. All units can be displaced in both compression and tension. The extensometer is supplied with the advanced DT6229 controller. The standard output is 0-10VDC analog signal, factory calibrated with the extensometer. This system provides a number of functional enhancements, including high speed digital output, built in calibration and tare functions, analog and digital filters, and more.

  • Camera Based Beam Propagation Analyzer: M2

    BeamSquared - mks Ophir

    The BeamSquared® system is a compact and fully automated tool for measuring the propagation characteristics of CW and pulsed laser systems from the UV to NIR to Telecom wavelengths. Users can also measure wavelengths above 1.8 microns, including CO2 and terahertz in manual mode (a bench set-up; without the automated optical train) with a Pyrocam IV or IIIHR. Our longer optical train and patented Ultracal™ Calibration makes BeamSquared the most accurate product on the market and is ISO 11146 compliant. Its operational robustness and reliability ensures continuous use applications in industry, science, research and development.

  • Total Sulfur Analyzer

    Model T108 - Teledyne Advanced Pollution Instrumentation

    The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas. Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and SO2.The Model T108 consists of a modified Model T100 SO2 analyzer with special software and a Model 501TS high temperature thermal oxidizer. Sulfur compounds are heated as they pass through the converter and oxidized into SO2. When analyzing CO2, which generally contains no oxygen, approximately 6% O2 is added to the sample before entering the converter. This dilution is corrected in the calibration procedure.

  • GC Analyzers

    Agilent Technologies

    Agilent’s GC Analyzer portfolio can combine multiple methods into a single system, with proven results, and significantly reduce time required from system arrival to final calibration and validation. With our preconfigured gas chromatograph hardware and method-specific separation tools, you can spend more time focusing on sample processing than on method and system development. Our specific GC Analyzer solutions provide the components and specifications to quickly install new methods for a fast return on investment in various application areas, such as environmental, gas impurities, forensics, pharmaceuticals, dissolved gas, energy, and chemical applications.

Get Help