Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 135 of 137 items found.

  • Electrostatic Potential Monitoring Device

    Kasuga Denki, Inc.

    electrostatic potential monitoring device that has an interface for connecting our potential sensors EMS-01 / EMS-01A / KS-2100 and measures static electricity in real time. It is possible to monitor static electricity with simple  The compatible potential sensor EMS-01 / EMS . With SD card support, measurement data and alarm history can be collected with a time stamp. Operation using the touch panel display and screen display, and to notify and manage the measurement status with multiple control outputs. ...-01A Has Passed The Intrinsically Safe Explosion-Proof Structure Certification In Combination With The Safety Cage KS-301A, And Can Be Used In A Dangerous Atmosphere.

  • Highly Dynamic XY Linear Motor Scanning Stage

    L-731 - Physik Instrumente GmbH & Co. KG

    The magnetic linear direct drive is designed to provide high velocity and acceleration for inspection and microscopy. With a travel range of 205 mm square and solid velocity to 100 mm/sec, the L-731 is equipped to deliver high accuracy and smooth motion. Precision crossed roller bearings with anti-creep cage assist enable superior guiding accuracy (1.5 m straightness for loads up to 20 kg). An integrated optical reference encoder and limit switch provide further positioning control and accuracy for this compact stage with 5 nm resolution. DC servo motor versions are available on request.

  • Cell Stand

    CS-3A - ALS Co., Ltd

    The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.

  • Animal Temperature Controller - Low Voltage

    TCAT-2LV - Physitemp Instruments

    Our TCAT-2 family of general purpose PID Autotuning Controllers provides accurate temperature control in a variety of laboratory applications. Combined with a heat lamp or heating pad, the TCAT-2 may be used to maintain the body temperature of anesthetized animals during surgery or stereotaxic procedures. Small animal cages are easily warmed with a heat lamp. The TCAT-2 may also be used in cooling applications, such as to control independent perfusate cooling systems. Realizing that laboratory applications are diverse, Physitemp can provide several versions of the TCAT Controller. The model specified depends on whether a laboratory has a general or specific need for the controller

  • 2-in-1 High-Voltage Test Hood

    LX-HVE900EC - LXinstruments GmbH

    The test cells are made of stable, highly insulating plastic and are closed by a swiveling, transparent cover. The built-in safety switch is used to lock the hood and release the high-voltage sources. This ensures that no high voltage is active when the door is open. There is a generously dimensioned wiring space in the floor of the test cage. An interchangeable adapter plate in the test cell - optionally with an interchangeable interface or an interchangeable adapter cassette - allows quick adaptation to different types of test items. Prepared openings enable connectors and other common interfaces or cable bushings to be easily attached. The hood is opened and closed almost effortlessly thanks to precisely coordinated gas springs.

  • Transceiver Driver

    S-112 - Notice

    Transceiver Driver slot module of FOTS system is an efficient module for the characterization of SFP type transceiver and the test of optical line or components. This module is a kind of Small Form Factor Pluggable(SFP) host board that can be used to test SFP transceiver modules to define the modules’ performance. The transceiver driver slot has two SFP cage and 20-pin SFP connector sets to mount and control two SFP transceivers simultaneously.

  • Autopilot Directional Gyroscopes

    4000C/D-series - Sigma Tek, Inc.

    The 4000C/D is an air-driven directional gyro with A.C. autopilot pickoffs. Left turns produce clockwise dial rotation and right turns produce counter-clockwise rotation. Two knobs control the gyro. The left knob is used to cage the unit, and the right knob is used to select the instrument’s heading. To change course, the right selector knob is pressed and turned to disengage the dial shaft and set the pointer to a new heading. Releasing the selector knob re-engages the pointer with the dial shaft. As the aircraft turns onto a new course, the pointer returns to its original position. The on-course position of the pointer is always at the top of the azimuth circle (0° on the dial with the aircraft headed north).

  • EMF Measurements/EM Measurements/Electromagnetic Radiation

    Holland Shielding Systems B.V.

    Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.

  • 2-in-1 High-Voltage Test Hood

    LX-HVE600EC - LXinstruments GmbH

    2-in-1 high-voltage test hood with integrated interchangeable setHV hood for electrical safety test & function test.The test cells are made of stable, highly insulating plastic and are closed by a swiveling, transparent cover. The built-in safety switch is used to lock the hood and release the high-voltage sources. This ensures that no high voltage is active when the door is open. There is a generously dimensioned wiring space in the floor of the test cage. An interchangeable adapter plate in the test cell - optionally with an interchangeable interface or an interchangeable adapter cassette - allows quick adaptation to different types of test items. Prepared openings enable connectors and other common interfaces or cable bushings to be easily attached. The hood is opened and closed almost effortlessly thanks to precisely coordinated gas springs.

  • Software AndSoftware Drivers

    Advanced Power Designs, Inc.

    Advanced Power Designs is the first to introduce programmable DC power supplies on dual C-Size VXI card formats. Designed specifically for easy integration into new VXI automatic test systems, these state-of-the-art power supplies are fully compliant with all VXI specifications for direct installation into any standard C-Size VXI card cage. They can even be purchased with LABVIEW, LABWINDOWS, CVI or HPVEE Graphical User Interfaces*, and a fully integrated command and control software program written for the National Instruments MXI I/O. protocol.

  • Magnetic Level Gauge Switches

    ABB Ltd.

    ABB's magnetic level gauge switches for point level alarm and/or control can mount to a KM26 magnetic level gauge or an LS Series cage level switch.These switches are completely isolated from the process fluid as they are magnetically activated by a magnet equipped float (KM26) or attraction sleeve (LS Series). The unique magnetic coupling action eliminates seals, diaphragms, springs, and torque tubes common to other level switching alternatives since there is no physical contact with the process fluid. The magnetic coupling also eliminates process connections to the switch; therefore, no isolation valves are required to block off the switch for maintenance. The switch "set point" is easily adjustable without changing any process piping and the result is a more reliable and easier way to maintain level system.

  • Low Voltage DC / Battery Powered High Voltage Amplifiers

    WMA-005 And WMA-005LF - Falco Systems

    The Falco Systems WMA-005 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 3mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-005LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.1mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • Low Voltage DC / Battery Powered HV Amplifiers

    WMA-01 And WMA-01LF - Falco Systems

    The Falco Systems WMA-01 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 3mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-01LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.1mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • Low Voltage DC / Battery Powered HV Amplifiers

    WMA-02 And WMA-02LF - Falco Systems

    The Falco Systems WMA-02 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 4mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-02LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.2mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • Crowbar Resistors

    Hilkar

    Crowbar resistors are three phase resistance banks which are connected to the rotor windings of the DFIG (Doubly-Feed Induction Generator) such as wind power generator. They are used to prevent damage to the inverter circuits attached to rotor side when a fault occurs in the grid. DFIG power converter, which has a restricted over-current limit, needs special attention during faults in the grid. If the rotor current or DC link voltage reaches the threshold value, crowbar resistors disconnect the converter in order to prevent the generator turning into a squirrel cage induction machine. By crowbar resistors, the DFIG could stay connected to the grid and continue its operation.

Get Help