Showing results: 1846 - 1860 of 2664 items found.
-
MT-26/2HT -
Physitemp Instruments
Fast-response 26 gauge needle probe, (needle length is 2 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
MT-26/4HT -
Physitemp Instruments
Fast-response 26 gauge needle probe, (needle length is 4 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
MT-26/6HT -
Physitemp Instruments
Fast-response 26 gauge needle probe, (needle length is 6 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
MT-23/8HT -
Physitemp Instruments
Fast-response 23 gauge needle probe, (needle length is 8 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
MT-29/1HT -
Physitemp Instruments
Fast-response 29 gauge needle probe, (needle length is 1cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
MT-29/2HT -
Physitemp Instruments
Fast-response 29 gauge needle probe, (needle length is 2cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
6067 -
Technobox, Inc.
The Technobox, Inc. P/N 6067 is designed to adapt a single-wide XMC card to a 1X PCI Express slot. The 6067 supports P15 only and allows access to PN4 signal via the adapter's DIN connector. The A and C rows of a 96-pin DIN connector connect with the 64-pin user I/O connector (J4/P4) on the mezzanine card, permitting internal connection of rear I/O. JTAG signals are brought out to headers allowing users the option of connecting the two JTAG ports.
-
Spectra Film Gate -
Spectra Cine, Inc.
The Spectra Film Gate Photometer II offered by Spectra Cine is a significant advance in the field of photometry. It is extremely sensitive and solid state throughout. Reads directly in printer steps of 0.025 log exposure units. The large, uncrowded scale has an 80 printer point range and affords ease and accuracy in reading. A variety of probes are available for use in Acme optical printers, Bell & Howell Model "C", "J", and "A" contact printers, ARRI printers and Oxberry printers.
-
377B11 -
PCB Piezotronics, Inc.
Performance:Nominal Microphone Diameter:1/2 CharacteristicPressureOpen Circuit Sensitivity: 50 mV/Pa50 mV/PaInherent Noise<15 dB(A) re 20 Pa<15 dB(A) re 20 Pa Dynamic Range (3% Distortion Limit)>143 dB re 20 Pa>143 dB re 20 Pa EnvironmentalTemperature Range (Operating)-40 to +248 F-40 to +120 C Temperature Coefficient of Sensitivity (+14 to +122F (-10 to +50C))0.005 dB/F0.009 dB/C
-
WIKA Alexander Wiegand SE & Co. KG
Thermocouples are temperature sensors that generate a voltage directly dependent on temperature. Compared to resistance thermometers, they are particularly suited for high temperatures up to 1,700 °C. Instrument designs from mineral-insulated sheathed cable are very resistant against extremely high vibration loads (depending on instrument model, sensor element and wetted materials). The accuracy classes 1 and 2 apply for thermocouples in accordance with IEC 60584 as well as the standard and special classes in accordance with ASTM E230.
-
Model T102 -
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
WRx Series -
Magna-Power Electronics, Inc.
Utilizing Magna-Power’s new patent pending Active Resistance Technology in combination with the company’s internally manufactured microchannel water-cooled heatsinks, the WRx Series addresses high power DC applications where exhaust heat control is essential. The WRx Series greatly increases power density compared air-cooled alternatives. An integrated solenoid controls the flow of water to avoid condensation. Full power can be achieved using conventional water, with water inlet temperatures up to 25 °C.
-
Panasonic Industrial Devices Sales Company of America
Mechanical Relay ideal for signal control, etc., with less than 2A nominal switching capacity. Low Level current switching below 2A. Features include gold contacts, stable contact resistance, fully sealed construction, Form C contact arrangement, available latching and low operating power, and compact size for optimal board space usage. Applications include: AC Control, Communications, Security, Measurement Equipment, Audio Visual Devices, and Automotive.
-
Lock-In -
OptoTherm, Inc.
Steady-state thermography is limited to detecting hot spots that heat up a minimum of 100 mK (0.100°C). This may be useful for locating shorts on high-power devices, but is inadequate for detecting low power defects such as semiconductor device leakage current or short circuit with very low or very high resistance. Steady-state thermography also suffers from poor spatial resolution as the heat from localized hot spots diffuses rapidly, blurring the location of the heat source.
-
CS2-TM-Analogue -
Chuan Sheng Electronics Co., Ltd.
The CS2-TM Totalizer controller provide high accuracy measurement, display, control and communication (Modbus RTU mode) of 0~10V/4~20mA from flow meter or mV from Shunt for Amp-Hour.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.