G9200 - Hermon Laboratories Ltd.
LTE test solution for development, verification and conformance testing of LTE mobile equipment. The G9200 RCA is able to perform analysis of LTE mobile devices at all layers from the physical to the application layer, and is suitable for development, conformance, pre-conformance, and production test applications.
-
DVS Endeavour - Surface Measurement Systems
A key feature of DVS Endeavour is the ability to precisely control and measure temperature and relative humidity while simultaneously recording the highest resolution changes in mass on up to 5 samples. Additionally Organic vapor partial pressures can now be directly measured using Surface Measurement Systems’ Speed of Sound sensor (patented).
-
SKZ1055A - SKZ Industrial Co., Ltd
Differential thermal analysis: temperature under program control, the relationship and difference oftemperature between the measured material and the material and the reference.The DTA curves is to describe the changing relationship depending on temperature and time between themeasured material and the reference compound. During the test, the sample temperature changes due tothe phase change or an endothermic or exothermic reaction effects.
-
SKZ1060 - SKZ Industrial Co., Ltd
Simultaneous thermal analysis (DSC/DTA, TGA) is a combination of differential heating and thermo gravimetric . It can not only study the change of sample quality with temperature or time in the process of heating and constant temperature, but also study and analyze the change process of the sample, by the heat generated changes. The purpose is to study the thermal stability and composition of the material.
-
SKZ1053 - SKZ Industrial Co., Ltd
Thermo gravimetric analysis (TG, TGA) is to observe the change of sample quality with temperature or time in the process of heating and constant temperature, the purpose is to study the thermal stability and composition of the material.
-
SKZ1055B - SKZ Industrial Co., Ltd
For measuring the heat of the main physical and chemical changes, such as melting point, melting heat,crystallization point, heat of crystallization, phase change heat of reaction, thermal stability (oxidationinduction period), the glass transition temperature.
-
BA8100 - B&K Precision Corporation
The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.
-
MEXA-584L - HORIBA, Ltd.
The MEXA-584L simultaneously measures CO, HC, CO2 (non-dispersive infrared: NDIR) and air-to-fuel ratio (AFR) or excess air ratio (A) in idle state. lt optionally measures O2, NO, engine speed (RPM) and oil temperature (TEMP). Lightweight and compact with a clear LCD and effortless operation, it can be used as a simple measurement instrument in any work situation.
-
Avcom of Virginia
Designed for the teleport, oil and gas, maritime, broadcast, military, TCSM, and wireless community. It is compact, portable, lightweight, and budget friendly for quick and precise signal investigations.
-
CI-IN261 - Shanghai ChangAi Electronic Science & Technology Co.,Ltd
CI-IN261 is based on NDIR principle and adopts digital processing technology as zero point/range point calibration, linear processing, temperature compensation, switch output, flow/voltage output, parameters setting etc. - See more at: http://en.ci-ele.com/sf/a55f582e-1bef-4eac-b401-bf24b8f7e1c8.shtml#sthash.6RCIN6uu.dpuf
-
GNL-IN121 - Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-IN121 is based on microprocessor, and keeps frequency current sensor as measuring point with intelligence, high accuracy and comprehensive function. It applies to the accurate measurement of oxygen concentration in 0~25.00% nitrogen- oxygen mixed gases. - See more at: http://en.ci-ele.com/8aedb8bf-ef48-4f8c-127a-797c939a6181/0e266f3f-134f-bfa1-4437-f6ee37fdb1dc.shtml#sthash.sNvnkmUs.dpuf
-
OCMA-500 - HORIBA, Ltd.
OCMA-500 to measure concentration of oil contained in drainage and environmental water.After injecting the water sample and solvent, all you have to do is press the start button,and the system will automatically conduct the monitoring operation from oil extraction to sample measurement and draining. With no more troublesome operations like opening/closing the drainage valve, monitoring is speeded up.In addition, the color graphic LCD and the backlit extraction tank have improved operability.
-
OCMA-550 - HORIBA, Ltd.
OCMA-550 to measure residual oil on components and concentrations of oil adhered on solids such as soil.Measurement can be easily made only by injecting the extracted water sample into the attached cell and setting it to the equipment.This model features a simple design which allows opening/closing of the door to setting of cell with just one hand.This is best for measurement of extracted samples such as evaluation of residual oil on components and measurement of oil contained in food.
-
T1 - TOCADERO Series - HORIBA, Ltd.
- Highest analytical precision with short measuring time- Catalyst-free high-temperature process at 1200°C with "Fast Change Technology- Most modern hardware components andindustry 4.0 features- Minimal material requirements and support costs- Highest processing quality- "Made in Germany"- Global service and support- Convincing cost of ownership
-
Yumizen C1200 AL - HORIBA, Ltd.
- Processes 1200 test/hour with ISEs- Dedicated STAT position- Random continuous access- Serum, Plasma and Urine samples- 90 refrigerated reagent positions- 61 dedicated refrigerated positions for calibrators and controls- Liquid level sensing- Clot detection- Cap/shock detection- Hemolysis, Icterus, Lipemia checks- Autoloader (optional accessory)