Showing product results. 1081 - 1095 of 3958 products found.
-
LD-LOGA-A10 - Labodam
Oil and Grease analyzerLD-LOGA-A10is a tabletop analyzer with a sample testing range of0.12 mg/L to 840 mg/L. The unit displays and prints the sample spectra, position and wavenumber of the absorption peak. It features self-contained optical and electrical system withhigh degree integration. Testing data and spectrograms can be saved to hard disk forchecking and printing anytime Sensor signal processing uses lock-in amplifier circuitimproving the analyzer’s SNR and the minimum detection limit.
-
HY-OPTIMA™ 700B Series - H2scan Corp.
H2scan’s HY-OPTIMA™ 700B series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 700B series is a solid-state sensor that is configured to operate in process gas streams with temperatures up to 60ºC. The HY-OPTIMA™ 700B series is ideal for hydrogen production and petrochemical applications where real-time measurements can enhance process plant efficiencies, diagnostics and maintenance management.
-
Model 6400TH - Teledyne Analytical Instruments
The 6400T Series analyzers uses a proven UV fluorescence principle coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level SO2. The 6400T-H2S measures hydrogen sulfide (H2S) by incorporating a catalytic converter set at 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 concurrently.
-
Model 6400T - Teledyne Analytical Instruments
The 6400T Series analyzers uses a proven UV fluorescence principle coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level SO2. The 6400T-H2S measures hydrogen sulfide (H2S) by incorporating a catalytic converter set at 600°F (315°C) to oxidize H2S into SO2 while leaving other more difficult to oxidize sulfurs unconverted. A switching mode allows analysis of both H2S and SO2 concurrently.
-
Model T201 - Teledyne Advanced Pollution Instrumentation
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter (see "Features" tab for external converter photo) to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.
-
CEA-100 - Walsn Enterprises Ltd.
Walsn CEA - 100 combustion efficiency analyzer is designed to continuously monitor CO content in flue gas while the measurement data can be used to adjust the ratio of fuel/ air so as to achieve the maximum boiler efficiency for boiler operation. Walsn CEA - 100 adopts the dual-measuring-sensor technology and features high accuracy with low zero drift and very small failure rate, matching the requirements of the harsh industrial environment. It is also easy to install and maintain.
-
PQPro - CANDURA Instruments
The PQPro™ is a portable 8 channel (4 voltage and 4 current) power quality analyzer that can stream high resolution waveform and RMS data to high capacity removable SD memory cards. Sampling rate can be adjusted from 64 samples per cycle to 1024 samples per cycle. The PQPro™ is in a rugged weatherproof enclosure that can be left recording in all kinds of environments - from the top of a utility pole to the bottom of an underground mine shaft!
-
Wuhan Sunma Technology Co., Ltd.
xDSL / PDH Analyzer mainly used for comprehensive transmission test of SDH/PDH network and equipment and widely applied in the R&D, manufacture, acceptance inspection, performance monitoring, maintenance and measuring of networks and equipment. The instrument SunmaFiber provided can insert and measure varieties of errors and alarms in PDH and SDH systems (including on-line and off-line test), perform performance analysis on various errors as well as modulate and test jitter signals at a max. test rate of 2488MHz (STM16).
-
Zirconia - Cosa Xentaur Corp.
The COSA Xentaur zirconia oxygen gas analyzers are widely used; not only in industries of high energy consumption, such as steel, power, petroleum/petrochemicals, ceramics, paper/pulp, food, and textile industries, but also in various combustion facilities, such as garbage incinerators and medium-to-small sized boilers, as combustion controllers, achieving a significant energy-saving effect. The oxygen concentration control ensures complete combustion, thus reducing CO2, SOX, and NOX emissions and helping prevent global warming and air pollution.
-
Rohde & Schwarz GmbH & Co. KG
The phase noise analyzer portfolio from Rohde & Schwarz offers an affordable, mid-range solution with high sensitivity and fast measurements as well as high-end ultra-high-sensitivity solutions with advanced measurements modes. Ideal for phase noise analysis and VCO tests, the industry-leading solutions enable two-path phase noise analysis with real-time cross correlation and fast VCO characterization with built-in low-noise DC sources. Additionally, high-end signal and spectrum analysis can be added into a single box.
-
Model 6200T - Teledyne Analytical Instruments
The Model 6200T Total Sulfur Analyzer utilizes proven UV fluorescent technology to continuously detect sulfur found in inert gas streams. An internal, quartz catalytic converter is employed to convert the sulfur, when mixed with scrubbed ambient air, into SO2 via higher temperature oxidation. An internal vacuum pump is employed to draw both the sample and the ambient air into the converter. The converted sample gas is fed to the fluorescence chamber where it is then exposed to ultraviolet radiation.
-
NCI Logic Analyzers
Three probe types are available for GoLogicXL logic analyzers: flying leadset, Mictor, and Pinpoint probes. The Mictor and Pinpoint probes are compatible with similar Keysight/Agilent "soft touch" and Tektronix "connectorless" probes. All GoLogicXL probes are coaxially shielded and use passive termination inputs to prevent loading the device under test. Both differential and single-ended input signals are supported by all probes. Input voltage swings small as 300 mV are supported in single-ended mode, and 150 mV for differential signals.
-
PerkinElmer Inc.
PerkinElmer is a leading supplier of IR and NIR instruments with more than 40 years' experience from developing solutions for the food and agricultural industries. Our expertise is unparalleled with deep knowledge in fields such as spectroscopy, chemometrics, Artificial Intelligence and software development. We offer the broadest portfolio in the market, with dedicated analyzers for specific applications like grain and dairy, as well as general purpose instruments suitable for a wide range of users, both for lab-based analysis as well as on-line process measurements.
-
O2CX - Cosa Xentaur Corp.
In-situ, real-time readings for optimal fuel efficiency of boilers, furnaces, and kilns, with fast and simple service ability, and all at a tremendous value. The COSA Xentaur O2CX Oxygen and COe Analyzer is the ideal choice to optimize fuel efficiency on most combustion sources and for stack oxygen applications. It has several significant advantages over other oxygen transmitters. The addition of our unique combustible sensor allows the process to safely operate with a lower Excess Air ratio, which translates into higher fuel efficiencies.
-
ORTEC
A single channel analyzer (SCA) produces an output logic pulse on the condition that the peak amplitude of its input signal falls within the pulse-height window that is established with two preset threshold levels. ORTEC provides two basic types or classifications of SCAs: non-timing SCAs and timing SCAs. Non-timing SCAs produce an output pulse if the input signal is within the window settings. Timing SCAs produce an output logic signal precisely related in time to the occurrence of the event being measured.