Showing results: 3931 - 3945 of 3964 items found.
-
Protea 2000 -
Protea Ltd
The Protea 2000 emissions monitoring system is approved for the analysis of exhaust gases from the engines and boilers of ships and offshore rigs. Robust and with proven reliability, up to six gases can be measured including SO2, CO2 and NOx.
-
C60 -
Cypher Instruments
The C60 investigates the opaque world of analog networks. The unit operates in two test modes. It can measure the frequency response of a two port system producing a gain/loss and phase graph. It can also measure the reactive response of a two terminal network producing an impedance/admittance and phase graph. Electronic, electrical, electro-acoustic and other networks can be tested with sine wave excitation and the results displayed on a PC.
-
DX4040 -
Quantitech Limited
The Gasmet DX4040, the only truly portable FTIR gas analyser in the world, is a lightweight battery operated system capable of measuring multiple gases (both organic & inorganic) at low concentrations simultaneously in real-time. The system has been developed based on the highly successful Gasmet DX4030 and shares the same optical components and internal hardware. Significant advances have been implemented to the operating software and control apparatus to make the Gasmet DX4040 one of the most versatile gas analysis solutions available.
-
QGA -
Hiden Analytical Ltd.
Hiden Analytical supplies precise and user-friendly tools for quantitative gas and vapour analysis. Our compact Hiden QGA system is a high performance gas analyser configured for real-time continuous monitoring of multiple species with an extremely wide dynamic range.
-
Meggitt
Our high performance analytical systems have been used in the nuclear industry since 1980. They enable operators to monitor hydrogen and oxygen levels at critical locations within both boiling water reactors (BWR) and pressurised water reactors (PWR).
-
HPR-20 EGA -
Hiden Analytical Ltd.
The Hiden HPR-20 EGA gas analysis system is configured for continuous analysis of evolved gases and vapours from thermogravimetric analysers, TGA.
-
DP-cPCI-7554 -
Data Patterns Pvt. Ltd.
DP-cPCI-7554 is a cPCI module capable of analyzing the phase and gain characteristics of a system. The system under test is stimulated by the user defined waveform. The obtained response is correlated with the applied stimulus by the on-board DSP processor to determine the phase difference and the gain.Gain and the face analysis is carried out only at sine waveform.
-
EA-300 -
Laplace Instruments Ltd.
The EA-300 is a stand alone unit with internal firmware and a large colour display. It connects to the outputs from a standard LISN and feeds the results to any standard EMC analyser or receiver. The EA-300 prompts the user through the steps necessary to fully characterise the emissions from the EUT, then will output via the screen the recommended filter component values that would reduce these emissions to acceptable levels.
-
ExQ -
Hiden Analytical Ltd.
The Hiden ExQ quantitative gas analyser is a new multi-featured and compact mass spectrometer system providing continuous on-line analysis of dynamic gas streams at pressures from sub-atmospheric up to 30 bar, the fully integrated system now being configurable both for benchtop and for rack-mounting operation. Connection to the process is via a flexible heated inert capillary line with a sample consumption rate less than 10 mL/minute and a response time of less than 300 milliseconds at pressures near atmosphere. The comprehensive range of process interface options enables adaptation of the system to accommodate analysis of up to 16 individual process streams, and adaptors are available for direct connection of the system to most standard TGA/TA instruments. External process data, sample temperature or mass for example, can be imported for combined integration and presentation with the mass spectral data.
-
ACM Instruments
The Portable Field Machine is our most versatile full specification corrosion testing instrument. Its rugged construction and protective water resistance IP68 enclosure enables it to be operated at extreme locations throughout the world. This instrument takes laboratory precision outdoors to oil rigs, pipelines, concrete walls and just about anything that needs corrosion monitoring in situ. The potentiostat, ZRA, integral Frequency Response Analyser and Sweep Generator are exactly as provided in the laboratory Gill 8 model ensuring the most accurate testing available. The choice of tests is not limited; the AC, IR Compensation and DC tests plus the Sequencer and Analysis that are supplied with this field instrument are the same as supplied with the laboratory instruments.
-
Ametek Land
LAND has a range of gas analysers suitable for boiler combustion monitoring and control. The close monitoring of oxygen, carbon monoxide and the sulphuric acid dewpoint temperature can help improve combustion efficiency, reduce excess air, reduce energy losses and prevent plant corrosion due to sulphuric acid formation.
-
Annie-USB -
New Forest Electronics
A top-quality 8-channel PC-based logic analyser with probably the highest specifications in its class, this Janatek product is excellent value for money. It captures data at a maximum rate of 500MHz, has a buffer depth of up to 1 Meg samples per channel, and incorporates an 8-bit pattern generator to aid debugging.
-
Logic-16 -
New Forest Electronics
A top-quality 16-channel PC-based logic analyser, this Janatek product is excellent value for money. It has a huge buffer depth of up to 1 Meg samples per channel, captures data at a maximum rate of 200MHz, and incorporates an 16-bit pattern generator to aid debugging
-
La-Gold-36 -
New Forest Electronics
A top-quality 32-channel PC-based logic analyser with class leading specifications, the Janatek La-Gold-36 offers a comprehensive digital debugging environment for the electronics professional. It captures data at a maximum rate of 1GHz and has a buffer depth of up to 1 Meg samples per channel.
-
Weis Gmbh & Co.
Range of Circuit Breaker Timing Testers / Switchgear Analysers