Filter Results By:

Products

Applications

Manufacturers

Analyzers

examine data methodically by separating into parts and studying their interrelations. AKA: Analysers

See Also: Analyze, Analytics, Analysis


Showing results: 3661 - 3675 of 3943 items found.

  • PXI-2541, 300 MHz, 8x12 PXI RF Matrix Switch Module

    778572-41 - NI

    300 MHz, 8x12 PXI RF Matrix Switch Module—The PXI‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXI‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXI‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.

  • Scanner Probe

    RFS set - Langer EMV-Technik GmbH

    The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.

  • Near Field Probes 30 MHz up to 3 GHz

    RF1 set - Langer EMV-Technik GmbH

    The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Electronic Load

    Fideris

    * Fully programmable, self-contained, air-cooled solid state load.* Patented design is optimized to provide ultra-low impedance operation for fuel cell testing.* Load is compatible with AC impedance or frequency response analyzers.* Interchangeable shunts for precise operation over a wide dynamic range.* Ten built-in cell voltage monitoring inputs optional. Additional voltage monitoring inputs available.* Ethernet Interface for simple configuration and expansion!* Combine with additional Fideris™ Innovator Series™ modules to create a fully-integrated,fully-automated, customized test system.* System-wide control of all Fideris™ Test System Components using FCPower™ Software,LabviewTM, or other programming language.* Integrated hardwired Run/Standby signal.

  • Micro probes 1 MHz up to 6 GHz

    MFA 01 set - Langer EMV-Technik GmbH

    The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Micro probes 1 MHz up to 1 GHz

    MFA 02 set - Langer EMV-Technik GmbH

    The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • NanoVIP® TWO™ PLUS

    Elcontrol Energy Net S.r.l.

    NanoVIP® TWO PLUS™ is a modern, compact and powerful portable Power Quality analyzer for professional use; it can be used on single-phase, two-phase, three-phase balanced networks, low and medium voltage as well as on chillers and pumping system to monitor all performance parameters.In addition to its electrical channels, it has 4 sensor channels to read whichever type of transducer: 4..20mA, 0..1V or PT to monitor and store data of whichever system.Thanks to the MRH™ hardware onboard, it can be connected to a QUADRA measuring network as a DGP device.A long lasting battery and the huge logging capability of data (over 1 year) are distinguishing characteristics that make it an absolute reliable and unique professional tool.

  • Collaboration, Reporting, And Analysis Platform

    Link-Live™ - NetAlly, LLC

    Serving as a centralized site survey, test results, analysis, and tester management system, the free Link-Live™ Cloud Service transforms team workflows with the ability to quickly and easily log, document, and report test activity from all NetAlly hand-held network testers and analyzers. Once the instrument is connected to the Link-Live Cloud Service, your test results are automatically uploaded to the dashboard for project management, analysis, collaboration and reporting. You have the option of uploading additional files, screenshots, images, profiles, packet captures, location information, and comments anytime. Also, certain NetAlly instruments with AllyCare Support can receive firmware updates “over the network” from Link-Live as they become available.

  • Sound Level Meter/Datalogger

    Extech SDL600 - Extech Instruments Corporation

    The SDL600 records data on an SD card in Excel format. High accuracy ±1.4dB meets ANSI and IEC 61672-1 Type 2 standards. 30 to 130dB measurement range. Auto or Manual ranging. AC analog output for connection to an analyzer or recorder. Large backlit LCD display. Stores 99 readings manually and 20M readings via 2G SD card. Datalogger date/time stamps and stores readings on an SD card in Excel format for easy transfer to a PC. User programmable sampling rate from 1 to 3600 seconds. Featuring Min/Max, Data Hold, and Auto Power Off functions. Complete with 6 AA batteries, SD Card, wind screen, and hard carrying case.

  • Microwave Cables Assemblies

    Panda Microwave Limited

    Panda Microwave specialize in the production of high performance microwave cable assemblies. We have a strong R&D team and advanced production and testing equipment. We have several automatic wire stripping machine from Switzerland, laser wire stripping machine, keysight vector network analyzer, CNC wire bending machines. Our cable assemblies have high performance, high quality, wide variety, superior performance, frequency coverage of DC~110GHz, widely used in radar, aerospace and other military and civil fields. Our price is highly competitive, and we set up long term relationship with more than 100 military institutes customers.

  • Stand-alone Software

    N4391AU - Keysight Technologies

    The analysis software from the N4391A optical modulation analyzer can be used on your PC without any instrumentation. It offers all the analysis capabilities of the N4391A including its advanced signal processing algorithms for complex modulated optical signals. Use this software to process and analyze raw data stored as .sdf, .mat or .csv files from N4391A or N4392A measurements. This capability allows you to work with the data as if you would work directly in front of the instrument. It is an excellent tool for developing your own signal processing algorithms and testing them off-line, together with your MATLAB compiler. In addition, this software is an effective tool for learning basic and advanced concepts of complex optical modulation, based on stored files.

  • Wastewater Samplers – Stationary

    Electro-Chemical Devices

    The ECD Analyzers range of automatic stationary, refrigerated wastewater samplers consists of three models, the AQUAS200, the AQUA-S320 and the rugged outdoor AQUA-S320H. At the heart of each is the well proven AQUA Sampling Module, a robust and reliable unit proven in thousands of applications worldwide and trusted by users as diverse as food manufacturers, water companies and the Environment Agencies. The air pump vacuum sampling system featured within the AQUA Module provides for an extremely accurate, reliable, representative and repeatable sample. Programming set-up and daily operation have been designed to be as simple and intuitive as possible for the user. Sample extraction can be time based or triggered by external sources such as flow meters, level sensors, pH meters, PLC’s etc.

  • Advanced Test Platform

    980 12G - Teledyne LeCroy quantumdata

    The Teledyne LeCroy quantumdata 980 12G-SDI Video Generator / Analyzer module supports video and audio functional testing of next gen broadcast monitors, conversion devices and sources up to 12G-SDI. The module is equipped with four (4)12G-SDI-capable output ports. The output ports can be aggregated for Dual link HD-SDI and Quad link 3G-SDI operation. A genlock input supporting both SD analog black burst and HD tri-level to sync the output clocks with a "house sync" but the module can also run off its internal clock. The module's four (4) SDI input ports can also be aggregated for Dual link HD-SDI and Quad link 3G-SDI operation. For single link operation only port 1 on the input or output is functional.

  • Amplitude Detectors with Isolators

    ERAVANT

    Full band waveguide detectors are GaAs beam lead Schottky diode-based detectors that are specially designed for millimeterwave network analyzer applications. With a proprietary circuitry design and careful diode selection, these zero-biased detectors exhibit high sensitivity and extremely flat output characteristics. The below standard offering covers the frequency range of 18 to 170 GHz and offers a 1 MHz video bandwidth and 1 MΩ video output impedance. The standard models also have the capacity to handle a maximum RF input power of up to +17 dBm. The RF interface of these detectors is a standard waveguide with an integrated Faraday isolator to improve the port VSWR. The output voltage polarity is negative and the connector type is a female SMA. Other configurations are offered as custom models.

  • Dual Temperature

    Fieldpiece Instruments, Inc

    The Fieldpiece Dual-Temperature Accessory, model ATH4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ATH4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ATH4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 on your Fieldpiece meter, handle or data logger. It is included with the HVAC Guide® System Analyzer to get target superheat and for the Target Evaporator Exit Temperature test. Fieldpiece offers a wide variety of k-type thermocouples for various HVAC specific applications. Use pipe clamp T/Cs with the ATH4 to check for blocked filters.

Get Help