Filter Results By:

Products

Applications

Manufacturers

Analyzers

examine data methodically by separating into parts and studying their interrelations. AKA: Analysers

See Also: Analyze, Analytics, Analysis


Showing recent results 3016 - 3030 of 3242 products found.

  • Current Sensing Probe

    Teseq AG

    The CSP 9160 is a broadband RF current sensor probe as defined in CISPR 16-1-2. Beside the compliance measurements of asymmetrical disturbance currents as e.g. required in CISPR 16-2-1 and CISPR 22, the probe can be used in a number of diagnostic applications to measure superimposed RF currents flowing in conductors, or cable harnesses.A convenient feature of the CSP 9160 is that, from 100 kHz to 120 MHz, it has a flat frequency response with a 0 dB transducer factor, allowing voltage measurements to be read as current, directly without any correction. The probe can be easily and quickly clipped around the cable under test and the RF currents measured using an oscilloscope, spectrum analyzer, or EMI receiver. Its large aperture (25.4 mm) can accommodate most cables and can handle power lines with currents up to 50 amps.

  • Dual Core Noise Test System

    DCNTS - Noise eXtended Technologies S.A.S.

    The DCNTS is a two channel Phase and Amplitude noise analyzer. Its dual demodulator architecture allows the system to use cross-correlation to cancel its internal noise and limitation; it is like comparing the outputs of 2 systems and only display the similarities while rejecting differences.It is capable of measuring absolute phase or amplitude noise but also residual phase noise under CW or pulsed conditions. The input frequency goes from a few MHz to 140 GHz. Residual noise testing is for devices like frequency multipliers or dividers, amplifiers or any other phase coherent input to output device.Pulse compatible, the system is perfect for very demanding Defense and Aerospace applications. Its state of the art dynamic range makes it the lowest noise floor instrument of the market.

  • Dynamic Dilution Calibrator

    Model T700 - Teledyne Advanced Pollution Instrumentation

    The Model T700 is a microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations using up to 4 gas sources.The Model T700 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and to enable production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPTs. To ensure the highest accuracy of NO2 output, the T700 with the photometer option can measure the ozone concentration prior to performing a GPT. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the Model T700, covering time periods up to a year.

  • Near-Field Probes 100 kHz up to 50 MHz

    LF1 set - Langer EMV-Technik GmbH

    The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.

  • Near Field Probes 30 MHz up to 3 GHz

    RF2 set - Langer EMV-Technik GmbH

    The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • IP Video Stream Analysis And Monitoring

    TSM100 - Mividi, Inc.

    The Mividi TSM100 is an MEPG transport stream analyzer and IP video monitoring system for monitoring the quality of digital video services (QoS) delivered via IP or ASI interfaces. It can simultaneously monitor up to 300 services and perform deep MPEG analysis and video quality check 24 x 7. The system can be used for analyzing MPEG-2, H.264 and HEVC programs delivered over the Internet, as well as head-end equipment that uses IP for video transmission. The TSM100 provides IP layer analysis, MPEG transport layer analysis, key frame decoding, audio loudness measurement and service profiling. The system receives IP encapsulated digital audio and video data via 1 Gbits or 10Gbits Network adaptor. It will monitor all media flows in the network, perform extensive tests on standard compliance and user profile matching, and generate alarms when TS, video or audio errors occur.

  • VC Verification IP for DisplayPort / eDP

    Synopsys, Inc.

    Synopsys, Inc. announces the availability of the industry's first Verification IP (VIP) and source code test suite for DisplayPort 1.4 with DSC 1.2 and for eDP 1.4a/b. With the increase in consumer demand for enhanced display resolution quality, Synopsys VC VIP for DisplayPort enables system-on-chip (SoC) teams to design these next-generation displays with ease of use and integration, resulting in accelerated verification closure. Synopsys VC VIP for DisplayPort 1.4 delivers advanced support for the highest display resolutions. It also features display stream compression (DSC) for visually lossless low-latency algorithms, increased resolution and color depths, and reduced power consumption. Synopsys VIP uses a Native SystemVerilog/UVM-based architecture to design next-generation display chips with optimum performance. Synopsys VIP is natively integrated with the Verdi Protocol Analyzer debug solution and features advanced debug ports. The VIP also features error injection capabilities, built-in-protocol checks, coverage and verification plans.

  • Signal Level Meter

    XR-3 - Applied Instruments, Inc.

    From satellite dish alignment, to UHF off-air antenna pointing, to cable TV MER measurements, the XR-3 is the meter for you! The XR-3 is the most capable meter offered by Applied Instruments. It's more durable than the popular Super Buddy meter, and has added features and performance. The XR-3's modular design with field swappable modules provides wide versatility to fit different measurement applications, including DBS satellite (i.e. Dish Network, DIRECTV, Bell TV, Shaw Direct), VSAT satellite (i.e. iDirect, Hughes Ku band, and more), VHF/UHF off-air (analog and ATSC digital), and CATV (QAM and analog). The XR-3 is great for installing and troubleshooting DISH SmartBox, Blonder Tongue, and other SMATV headend systems often used in hotels, multi-dwelling units, and institutional facilities. Modular Test Instrument. Satellite Finder. Installer Signal Meters. CATV Analyzer. Modules.

  • Infrared, Near Infrared and Raman Spectroscopy

    Bruker Corporation

    rom the very compact FTIR spectrometer to the world’s highest resolution: Bruker offers the industry's largest selection for demanding routine and High End FTIR research application including the new and unique verTera cw THz functionality.Process monitoring with FTIR / FT-NIR process spectrometers.A complete line of Near Infrared Spectrometers to fit all your needs, including Process Monitoring.FTIR Microscopy and Raman Microscopy and Spectral Imaging for high sensitivity at high spatial resolution.High spectral resolution, high performance Raman and FT-Raman spectrometers for advanced routine solutions.FTIR Gas Analyzers for the fully automated and high precision real-time monitoring of gas compoundsImaging Remote Sensing systems for analysis of gases, liquids and solids.CryoSAS semiconductor material quality control for photovoltaic and electronics industry.OPUS, the "all-in-one" IR and Raman spectroscopy software consists of a suite of software packages that cover both standard and specialized applications.ONET, software for the setup, administration and control of large FT-NIR spectrometer networks.

  • Near Field Probes 30 MHz up to 3 GHz

    RF6 set - Langer EMV-Technik GmbH

    The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Ethernet 400G Verification IP

    VC Verification IP (VIP) - Synopsys, Inc.

    Synopsys VC Verification IP (VIP) is architected to address the challenges of verifying today's highly sophisticated and complex SoC designs. VC VIP is written entirely in SystemVerilog to deliver greater performance, ease-of-use and extensibility to speed and simplify test bench development, verification and debug. The VC VIP portfolio of bus memory and interface VIP includes support for Verdi Protocol Analyzer, a simulator independent protocol aware debug environment that enables users to quickly debug protocol and memory issues and easily share protocol-based simulation results across teams. VC VIP is implemented entirely in SystemVerilog and architected for native support of UVM and VMM without the need for methodology-level interoperability wrappers or language translations. It provides full visibility into classes, callbacks, and messages and enables true SystemVerilog-based constraints. This streamlining of the VIP structure results in much greater performance and methodology support; it also provides support across all simulators without degrading performance or methodology.

  • LED Power Driver ATS

    8491 - Chroma ATE Inc.

    1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series

  • IEC61850 Digital Substation Testing

    Ponovo Power Co., Ltd.

    With the development of power system, more and more digital substation based on IEC61850 has been built in the world. IEC61850 is the new communication protocol which is adopted by power system so as to change the analog complicated wiring connection and protocol conversion. Based on IEC61850, all Messages, such as GOOSE, SV, MMS, PTP, etc, could be communicated on the Ethernet via fiber optical cable connection. In China, the digital substation have started since 2003, until now there are already more than 6000 digital substation put on operation, China Power Grid is planning to build 5000 more new digital substations. PONOVO, as the leading power system testing solution provider, have launched plenty of IEC61850 digital testing tools, not only digital relay test set, but also MU test set, multi-functional analyzer, 24 hours online monitoring and analyzing system, etc so that users could have suitable testing equipment for the digital substation commissioning and testings.

  • Sample Conditioner

    PCA-400 - Bacharach, Inc.

    Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

  • Near Field Probes 30 MHz up to 6 GHz

    XF1 set - Langer EMV-Technik GmbH

    The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.