  • Gaussmeter

    GM2 - Alpha Lab, Inc.

    The Model GM2 Measures the strength and polarity of magnetic field up to 30kG when using a standard probes, or 800 gauss (resolution 0.01 gauss) if an HS probe is used. Functions include DC, AC and peak hold along with a user-adjustable alarm which has three modes of operation. DC background field can be subtracted out either by pressing "Relative Zero" or by manually adjusting the offset. The meter includes battery, AC adapter analog output jack and calibration certificate. If a standard probe is used, resolution is 0.1 gauss up to 19,999.9 gauss, which is stronger than the field of any permanent magnet. This 5 digit display allows measurement of tiny difference in strong fields. Above 20kG the meter autoranges to a 30kG range.

  • Oscilloscopes

    T3DSO3000 Series - Teledyne LeCroy

    Teledyne Test Tools new T3DSO3000 Oscilloscopes feature four channel models with analog bandwidth options from 200 MHz to 1 GHz. Each model offers a maximum sample rate of 5 GSa/s, and a maximum memory depth of 250 Mpts in half channel mode. All models incorporate two 5 GSa/s ADCs and two 250 Mpts memory modules. When all channels are enabled, each channel has sample rate of 2.5 GSa/s and a standard record length of 125 Mpts. When only a single channel per ADC is active, the maximum sample rate is 5 GSa/s and the maximum record length is 250 Mpts. For ease-of-use, the most used functions can be accessed with its user-friendly front panel design.

  • Oscilloscopes

    T3DSO2000 Series - Teledyne LeCroy

    Teledyne Test Tools new T3DSO2000 Oscilloscopes feature two channel and four channel models with analog bandwidth options from 100 MHz to 300 MHz. Each model offers a maximum sample rate of 2 GSa/s, and a maximum memory depth of 140 Mpts in half channel mode. The four channel models incorporates two 2 GSa/s ADCs and two 140 Mpts memory modules. When all channels are enabled, each channel has sample rate of 1 GSa/s and a standard record length of 70 Mpts. When only a single channel per ADC is active, the maximum sample rate is 2 GSa/s and the maximum record length is 140 Mpts. For ease-of-use, the most commonly used functions can be accessed with its user-friendly front panel design.

  • Sync Generator

    LT 4610 - Leader Electronics Corp.

    The LT 4610 is 1RU full-rack size sync signal generator that can output triple-rate SDI (3G-SDI/HD-SDI/SD-SDI) signals. It employs two power supply units for redundant operation to protect against power supply failures. The genlock function for external sync signals enables SDI signals, six sets of analog black burst sync signals, and audio word-clock signals to be output synchronously. The genlock function is equipped with a STAY IN SYNC function that maintains the phase when errors occur in the input signal, making it possible to provide stable sync systems.In addition to test pattern output including color bars and SDI check fields, the LT 4610 can embed ID characters, QVGA logo marks, safety area markers, and embedded audio in a SDI signal output.

  • Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines

    SP-RS485-12V-O - Network Technologies Inc

    Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.

  • AC Power Source

    61600 Series - Chroma ATE Inc.

    Built-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable voltage,current limitComprehensive measurement capability,V, Hz, Irms, Ipk, Iinrush, P, VAR, VA, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlOne-key recall for 9 different voltage and frequencyProgrammable slew rate setting for changing voltage and frequencyAnalog input for power amplifierOptional Analog programming interfaceOptional GPIB and RS-232 interface(Model 61601~61605)Full protection: OP,OC,OV and OT protectionEasy use graphic user interface: softpanel (option)Capable of delivering power output up tp 90KVA by implementing Master-Slave operation

  • Mass Flow Controller for Medium Flow

    HFM-201 / HFC-203 - Teledyne OEM Solutions

    The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 me​ters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.

  • M​​ass Flow Controller for Medium Flow

    HFM-205 / HFC-207 - Teledyne OEM Solutions

    The HFM-205/HFC-207, Teledyne Hastings' flexible,​ general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications.

  • Low Pressure Drop Thermal Mass Flow Meter

    HFM-200 LFE - Teledyne OEM Solutions

    The HFM-200 LFE Series by Teledyne Hastings can be configured and accurately measure gas flow in a broad array of applications. Featuring reliability and stability, the 200 Series is chosen by users for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow meter compatible with most gases.The HFM-200 LFE meter has flow ranges from 0-10 sccm to flows of 0-15,000 slm; provides analog outputs, and is constructed of stainless steel. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Cleaning for oxygen service is available. Our laminar flow elements (smooth, threaded or flanged) are available in various sizes from 3/8" up to 8". Low pressure drops at full scale flow.

  • Power Amplifiers for Radio Amateurs

    Kuhne electronic GmbH

    From classic equipment for simple QSOs to high performance modules for contests, EME-operations and satellite radio: Our products provide absolute top performance. When choosing their equipment many radio amateurs and club-stations don't compromise and trust in the proven quality of Kuhne electronic amplifiers. Numerous contest victories, records and first contacts with a country were and are achieved with Kuhne products. Our amplifiers are remarkable for high gain and high linearity. LD-MOSFET and GaAs-FET-systems are the state-of-the-art technology in the amateur sector and enable the perfect use for all analog and digital modes (e.g. SSB, CW, WSJT, ATV, DATV). Small mechanical measurements and milled aluminum cases enable high temperature stability and tower mounting. Don't compromise and get technology from Kuhne electronic!

  • Auto Range Bench-Type DMM

    VC8145 - KILTER ELECTRONIC CO.,LTD

    1. Large LCD. High contrast. Wide visual angle LCD display. white backlight 2. Dual-display:Main display 80000,Vice-display 80000,analog bar 21 sect, unit,function symbol complete 3、50 kinds of measuring function,With basicly DCV、ACV、DCA、ACA、Ω、CAP、Hz、TEMP、diode and Continuity measuring function etc; 4、Frequency measuring can rearch 80MHz; 5、Standard function generator:18 kinds of frequency,1%─99% Duty cycle,1800 pcs wave output; 6、Single analyzed:(AC+DC) measuring synchronous,(AC+Hz) measuring synchronous,(DC+dBm) measuring synchronous,(dBm+Hz) measuring synchronous,(Hz+Duty) measuring synchronous,(℃+℉) displaying synchronous;

  • SGMA Upconverter

    SGU100A - Rohde & Schwarz GmbH & Co. KG

    The R&S®SGU100A SGMA upconverter offers a frequency extension to 40 GHz. When the R&S®SGS100A and the R&S®SGU100A are connected, they act as a single instrument for both remote control and manual operation. The combined instruments offer the same connections as the R&S®SGS100A: one RF output for the entire frequency range and one analog I/Q input for vector modulation. In this setup, tasks are automatically distributed between the two instruments so that users feel as if they are operating a single instrument.Equipped with the R&S®SGU100A, the R&S®SGS100A covers the entire frequency range from 10 MHz to 40 GHz without modulation, and from 80 MHz to 40 GHz with vector modulation.

  • M​​ass Flow Controller for Medium Flow

    HFM-205 / HFC-207 - Teledyne Hastings Instruments

    The HFM-205/HFC-207, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications.

  • Low Pressure Drop Thermal Mass Flow Meter

    HFM-200 LFE - Teledyne Hastings Instruments

    The HFM-200 LFE Series by Teledyne Hastings can be configured and accurately measure gas flow in a broad array of applications. Featuring reliability and stability, the 200 Series is chosen by users for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow meter compatible with most gases.The HFM-200 LFE meter has flow ranges from 0-10 sccm to flows of 0-15,000 slm; provides analog outputs, and is constructed of stainless steel. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Cleaning for oxygen service is available. Our laminar flow elements (smooth, threaded or flanged) are available in various sizes from 3/8" up to 8". Low pressure drops at full scale flow.

  • Mass Flow Controller for Medium Flow

    ​​HFM-201 / HFC-203 - Teledyne Hastings Instruments

    The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.