Filter Results By:

Products

Applications

Manufacturers

Showing results: 1381 - 1395 of 1758 items found.

  • PC Control Tunable Laser Source Modules

    GM82009xx - UC Instruments, Corp.

    The GM82009C, GM820093L and GM82009CL tunable laser modules offer superior performance in testing DWDM components, AWG & PLC components, and optical amplifiers, and performing other general- purpose fiber optical test and measurement applications particularly in fiber grating sensor fast sweep testing.

  • 1-Channel 3.6 GHz or 2-Channel 1.8 GHz 12-bit A/D with DDC - XMC

    Model 71641 - Pentek, Inc.

    - Ideal radar and software radio interface solution- One-channel mode with 3.6 GHz, 12-bit A/D- Two-channel mode with 1.8 GHz, 12-bit A/Ds- Programmable one- or two- channel DDC (Digital Downconverter- 2 GB of DDR3 SDRAM- Sync bus for multimodule synchronization- PCI Express Gen. 2 interface x8 wide- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Clock up to four modules with Model 7194 High-Speed Clock Generator - PMC/XMC- Synchronize up to four modules with Model 7192 System Synchronization and Distribution Amplifier - PMC/XMC- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

  • Micro probes 1 MHz up to 6 GHz

    MFA 01 set - Langer EMV-Technik GmbH

    The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Micro probes 1 MHz up to 1 GHz

    MFA 02 set - Langer EMV-Technik GmbH

    The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Light-to-Analog Sensors (Voltage)

    Renesas Electronics Corp.

    Renesas' light-to-voltage silicon optical sensors combine a photodiode array, a non-linear current amplifier and a micropower op amp on a single monolithic IC. Applications for these devices include display backlight control, keypad dimming, anti-glare mirror systems, and industrial and medical light sensing applications.

  • Current Sensing

    Texas Instruments

    voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.

  • Decade Capacitor

    1419 Series - IET Labs

    GenRad 1419-A and GenRad 1419-B (Polystyrene) Owing to its very low dielectric absorption, the GenRad 1419A 3 Decade 1000 pF/step & 1419B 4 Decade 100 pF/step Polystyrene Decade Capacitors are particularly useful in research and development work on computer and integrator circuits and on low-level amplifiers. Its constancy of capacitance and dissipation factor as a function of frequency also makes it extremely useful in measuring circuits and as a component in filters and tuned circuits. High insulation resistance and low dielectric absorption make it the 1419 Decade Capacitor a nearly ideal capacitor for dc work.

  • Miniature

    Columbia Research Laboratories

    This group is made up of the 6000 and 7000 Series Accelerometers. The 6000 Series offers detachable cables and connector assemblies, a special inverted seismic element for mechanical isolation and other features normally available only on standard size sensors. The 7000 Series are true "shear-mode" design accelerometers which offer performance characteristics and accuracies normally only available with standard size accelerometers. High temperature models of these series are available and will operate to +500°F. For best performance use with Columbia Model 4601 Charge Amplifier or Model 5810 Inline Charge Converter.

  • MIPI Soundwire Total IP Solutions

    Soundwire - Arasan Chip Systems, Inc.

    Soundwire is suited for small, cost-sensitive audio peripherals such as modern digital class-D amplifiers and digital microphones. The Total MIPI SoundWire IP Solution from Arasan enables early adopters the fastest path to adoption of this new standard by offering a comprehensive IP package that includes the Verilog RTL source code for Master and Slave, fully validated for compliance with the standard, a comprehensive test environment with a compliance suite for verification of the IP package, a SoundWire Hardware Development Kit (“HDK”) for FPGA prototyping, a SoundWire protocol analyzer and a complete SoundWire software stack.

  • Power Meters

    Rk-5700 - Laser Probe Inc.

    The Rk-5700 Series Power Meters accept a wide variety of probes – pyroelectric, silicon, and thermopile – enabling them to perform absolute radiometry, total laser power (cw and average), and irradiance measurements from the UV to far-IR, pW to kW. Integrated lock-in amplifier circuitry allows for synchronous detection of chopped optical signals, improving both S/N ratio and background rejection. The dual channel Rk-5720 simultaneously measures Channel A, Channel B, and the ratio B/A. An IEEE-488 GPIB computer interface, Analog Outputs, Background Cancel, and Autorange are all standard features.

  • Spectrum Analyzer

    SA-S - EMC Test Design, LLC

    RF Frequency Range: 1 Hz to 4.2 GHz. Low noise amplifier available above 500 KHz. Wide dynamic range: -151 dBm to +10 dBm. Resolution bandwidths (RBW) of 0.1 Hz to 250 KHz and 5 MHz. Includes a High Dynamic Range Measuring Receiver. 0.25 dB relative accuracy. 0 dBm to -125 dBm, 150 KHz to 1 GHz. 0 dBm to -115 dBm, 1 GHz to 4.4 GHz. Adjustable digital audio filters. Accurate AM and FM measurements

  • Optical Detector

    LG-9200 - Ono Sokki

    The LG-9200 is a non-contact type optical detector which emits red visible light and detects the reflected light from the rotating shaft. The reflection mark is used for the detection by affixing it on the rotating shaft. It enables detection at an angle. (reflective mark: HT-011 by Ono Sokki)The LG-9200 has a built-in compact amplifier and outputs the square wave (voltage) after waveform shaping.With a compact and light weight body, performances are upgraded compared to the previous model LG-916.(LG-9200 detection distance: up to 40 mm, response speed: up to 40 m/s)

  • AC Source

    AFC - Intepro Systems

    The AFC Series products are single and three phase AC Power sources ranging from 0.5kVA to 2000kVA. This AFC series has a continuous and adjustable output voltage between 5~300V. This allows for quick and convenient 3 scales of preset voltage for high and low voltage simulation. Power is supplied by state-of-the-art IBGT pulse width-modulated power amplifiers resulting in highly efficient power conversion, compact design and maximized performance. With up to 90% efficiency the AFC minimizes heat dissipation so less infrastructure cooling is required.

  • Differential Scanning Calorimeter

    DSC-L600 - Thermtest Instruments

    The Differential Scanning Calorimeter (DSC-L600) is a powerful thermal analysis instrument that measures the heat flow of a sample as a function of time or temperature. The DSC-L600 has been designed to be a cost-effective instrument that is well suited for research or QC applications. The instrument communicates with the PC via a RS232/USB connection. The specially designed heat flux plate has demonstrated more than twice the sensitivity than other heat flow type DSC’s on the market. The reproducibility is excellent, and the noise level is virtually unnoticeable due to a precision high gain, low noise differential amplifier

  • Integrated Assemblies

    Teledyne RF & Microwave

    Teledyne RF & Microwave offers full first-level integration capabilities, providing not just performance components but also full subsystem solutions to help reduce program schedule and cost. Drawing on our expanding breadth of components, Teledyne RF & Microwave delivers customer-specified subsystems of analog and mixed analog-digital design, including hybrid, MMIC, and mixed hybrid-MMIC configurations. Designed to meet military or space applications, some typical subsystems Teledyne RF & Microwave delivers include I/Q demodulators, coupled detector assemblies, switched amplifier detector assemblies, and dual-band VCOs.

Get Help