Showing results: 1246 - 1260 of 1761 items found.
-
DN2.445-02 -
Spectrum Instrumentation
The digitizerNETBOX DN2.44x series allows recording of one, two, four or eight synchronous channels with sampling rates of 130 MS/s up to 500 MS/s. These products offer outstanding A/D features in resolution, bandwidth and speed as a remote instrument. The powerful A/D amplifier section offers six different input ranges, two input paths, AC/DC coupling and noise reduction filters.
-
Megger Group Ltd.
Megger’s comprehensive range of products for relay tests includes high current primary injection, relay phase angle, end to end line protection GPS timers and relay current amplifiers.
-
MVR Series -
Innovative Technical Systems
The MVR Series of Muzzle-Velocity Radars are Doppler-CW transceivers that measure the velocity of viewed objects such as projectiles. They use phase-locked millimeter-wave transmitter-receivers along with an integrated radome-protected antenna to illuminate objects under investigation. An optical boresighting aid provides alignment assistance for the narrow radiation patterns. Reflected signals from the target are received by the antenna and mixed to produce a video output equal to the Doppler spectrum of the target. A low-noise, variable gain video amplifier can drive a 50-ohm cable up to +1 volt output. The video amplifier has a feed-forward DC offset compensation circuit that extends the Doppler frequency response from under 1 Hz to over 2 MHz. An integrated DMM and LCD display on the front panel monitors various test points within the sensor to verify proper operation. The extremely rugged design allows the MVRs to withstand high acousitic shock environments so they can be located in close proximity to the projectile source.
-
Barfield Inc.
Fuel capacitance systems are separated into two broad groupings, AC capacitance and DC capacitance. The source of these names derives from the type of signal processed by the fuel system amplifier. Barfield designs a universal tester for each type of system with the proper interface harnesses to access individual aircraft applications. Some of the various test and measurements include:*Insulation - Testing the wiring and probes*Fuel Tank Capacitance Measurement*Individual Probe Capacitance Measurement*Capacitance Simulation - Indicators and amplifiers*Indicators - Bench testing of remote units
-
Power Diagnostix Systems GmbH
Although differential and isolation amplifiers can eliminate some of the many possible sources of error and at least reduce their effects, only fiber-optic isolation amplifiers bring definite relief. Optical isolation of measuring circuits eliminates long measuring cables prone to electromagnetic interference, and potential differences of several hundred kilovolts become possible between measuring and recording circuits.Applying fiber optic isolation with high impulse-current applications allows the ground potential to have dramatically transient changes without affecting the integrity of the signals captured and transmitted.
-
HCP-1801 -
Grass Valley Canada
The HCP-1801 HD/SD control probe integrates many advanced features for monitoring both video and embedded audio signals, including a new macro-block detection option (see page xx). It offers complete real-time measurement and analysis of signal parameters, as well as flexible alarm thresholds and user-defined profiles. In addition, the probe functions as a distribution amplifier, with a single input and four HD or SD reclocked outputs.
-
DS3 -
NTi Audio AG
The Dodecahedron Speaker Set offers a lightweight, yet powerful signal source for room & building acoustic measurements. The optimized frequency response ensures precise measurements in accordance with the ISO 16283 and the ISO 3382 standards. The set includes the robust omnidirectional DS3 odecahedron Speaker and the remote-controlled PA3 Power Amplifier. Equalized acoustic frequency spectrum from 100 Hz to 8 kHz.
-
STMicroelectronics
ST's wide range of rad-hard QML-V qualified analog ICs covers analog-to-digital converters (ADC) and digital-to-analog converters (DAC) for telemetry, instrumentation and imaging applications. Our portfolio also includes rad-hard op amps, high-speed differential amplifiers up to 1 GHz, shunt voltage references and comparators to ensure a complete solution for signal conditioning, referencing and data conversion.
-
Ametek Scientific Instruments
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
LMV358 -
SparkFun Electronics
This is a simple 5V Op Amp breakout board, set up as a 2-stage amplifier with a gain of 100 (gain of 10 for each stage). The on-board trim pot sets the signal level between the stages, not the feedback path. The bandwidth is set to 15.9kHz by a pair of feedback capacitors, or over 100kHz with the caps removed. The LMV358 opamp can source up to 160mA and works well as a low impedance driver/buffer.
-
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
EM-7021 | 2 GHz – 5 GHz -
Electro-Metrics Corp.
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
EM-7020 | 1 GHz – 2.5 GHz -
Electro-Metrics Corp.
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
EM-7022 | 4 GHz – 10 GHz -
Electro-Metrics Corp.
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
Teledyne RF & Microwave
Teledyne Microwave Solutions (TMS) offers Voltage Controlled Oscillators (VCOs) utilizing bipolar transistors & silicon varactors over the frequency range of 40 MHz to 18GHz. Many of the VCO designs incorporate internal filtering, regulation & amplifiers to meet total system requirements in a small integrated package. Additionally, our hermetic hybrid designs can be screened to the most demanding military and space applications.