Showing recent results 976 - 990 of 1481 products found.
-
Kyowa Instruments
This system is used to measure the stress exerted on pipes due to the vibration of compressors in air conditioners, etc.The system synchronously measures 16 strain gages and records data under the specified conditions.The system consists of bridge box, strain amplifier, PC, and control/analysis software, etc.
-
LXinstruments GmbH
The application encompasses functional tests of very large quantities of automotive antenna amplifiers, plus parallelization of tests by implementing several test stations in a rotary indexing table. The DUTs are inserted manually and after final assembly, they are loaded into the rotary table; this requires manual triggering by the operator.
-
FX-550 - Panasonic Electric Works Corporation
The FX-550 Digital Fiber Sensor or Fiber Optic Amplifier has three times higher emission power and 1.6 times longer sensing range than conventional models. Higher incident light intensity results in more stable detection and easy beam axis adjustment.
-
81663A - Keysight Technologies
The Keysight 81663A Distributed Feedback Laser Sources are part of the Keysight Lightwave Solution Platform, and best suited for amplifier test and WDM system test applications. Keysight covers PON and common WDM wavelengths with its 81663A Distributed Feedback (DFB) laser source modules.
-
PCI321 - AcQ Inducom
The PCI321 Intelligent Stepper Motor Controller with amplifiers is an ideal solution for all applications where stepper motors must be controlled with a maximum of flexibility and a minimum of overhead. The local processor handles all high-level commands to provide maximum control for both straightforward as very complex applications.
-
Laser Quantum Ltd.
Laser Quantum exclusively provides comprehensive solutions for the emerging market of OPCPA technology - the most direct approach for amplified high-power, few-cycle femtosecond laser pulses. Unlike for other commonly used amplification concepts such as Ti:sapphire-based multipass or regenerative amplifier systems, the parametric amplification process of Optical Parametric Chirped Pulse Amplifiers (OPCPA) features a much larger gain bandwidth and no gain narrowing; thus is ideally suited to support the bandwidth and pulse duration generated by the broadband venteon femtosecond oscillators directly from the amplification process. Laser Quantum provides the only commercially available OPCPA product offering MHz repetition rate at microjoule pulse energy and sub-8 fs, with complete CEP stabilization available.
-
Thorlabs, Inc.
Welcome to Thorlabs; below you will find links to light emitters, sources, and controllers, a subset of our entire line of photonics products. Our light sources are conveniently separated into coherent and incoherent sources. The coherent source category includes laser diodes, laser diode modules, tunable lasers, HeNe lasers, and femtosecond lasers, while the incoherent source link brings you to a selection of LEDs, white light, and broadband SLD sources. The Quantum Electronics category includes optical amplifiers, modulators, and gain elements that are frequently used in research and OEM applications. All of our light sources and optical amplifiers are supported by an extensive line of mounts, sockets, TEC controllers, and current controllers.
-
MFA 02 set - Langer EMV-Technik GmbH
The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
MFA 01 set - Langer EMV-Technik GmbH
The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
Hubbell Power Systems Inc
The purpose of the Energized Cable Sensor is to allow the lineman to readily determine whether a URD cable is energized. The sensor consists of an amplifier which is designed to give a meter reading when the small AC voltage between the semi-conductive sheath and the concentric neutral of the energized URD cable is applied to the test probe. The amplifier is housed in a rugged phenolic case. Sensor may be used to check for energized condition on concentric-neutral cable below an elbow without test points. At cable mid-span (left), hose clamps bridge all strands of concentric neutral at the test location. Sensor’s neutral lead clips to one of the hose clamps. Tip on probe lead contacts only semi-conductive cable sheath to test for voltage presence.
-
Panasonic Electric Works Corporation
Panasonic offers a comprehensive lineup of high performance Photoelectric, Fiber and Laser sensors. Compact and miniature Photoelectric Sensors with easy-to-implement enclosure shapes are available with or without a built-in amplifier. Panasonic Optical / Photoelectric Sensors are ideal for reliable distance sensing applications in automation and production environments.
-
PZD700A - TREK, INC.
Trek PZD700A high-voltage DC-stable piezo drivers / amplifiers are designed to provide precise control of output voltages in one of three, user specified, voltage ranges: 0 to ±700 V (±100 mA), 0 to +1.4 kV (±50 mA), or 0 to -1.4 kV (±50 mA).
-
SIM914 - Stanford Research Systems, Inc.
The SIM914 350 MHz Preamplifier contains two wide-bandwidth, DC-coupled amplifiers, each with a gain of 5 (14 dB). Its fast rise time, low noise and excellent DC accuracy make it an ideal instrument for amplifying signals like those from photomultiplier tubes and photodiodes.
-
"V45A" - Anfatec Instruments AG
This low-noise 3-channel high voltage amplifier V45A wasdesigned for the control of tube scanners in scanning probemicroscopes. Three inputs with 10 V are amplified into twoasymmetric output voltages (Xout = 45 V and - Xout= - 45V) in the channels X and Y, while the Z-channel is 90 V relativelyto ground.
-
Wilcom Incorporated
Despite the growth in digital and fiber systems, many telephone companies still require basic line treatment products. Wilcom's hard-to-find line treatment products help the telecommunications industry deliver the performance the customer expects. Products include line powered amplifiers and RFI filters.