product
Transformer Winding Resistance Meters
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
product
Differential Transformer Type Extensometers
DT Series
ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.
-
product
Linear Variable Differential Transformers (LVDTs)
Whilst there are several ways to measure displacement, the Linear Variable Differential Transformer (LVDT) remains a popular transducer in most industrial applications. LVDTs initially were used as a means of taking dimensional readings in laboratories. They gained popularity in a wide variety of industrial monitoring and control applications, and whilst an LVDT is used to measure displacement the technology can be employed within other transducer types.
-
product
Current Transformer
ST-60CT
Standard Electric Works Co., Ltd
● 400/5A - 800/5A● 7.5-10V A● Class 1● Insulation 600V
-
product
High Quality Transformer Oil Dielectric Strength Tester
AS-023A
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
product
Filament Transformers
Osborne designs and produces high impedance and unregulated Filament Transformers. An unregulated filament transformer supplies a specified voltage and current to the filament of an electron vacuum tube. High impedance filament transformers are designed around a tungsten tube filament. Osborne often works with our clients to increase the life-span of their vacuum tubes through the use of a regulated voltage supply.
-
product
Isolation Transformers 230V
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
product
MOTORIZED VARIABLE TRANSFORMER CONTROLLED POWER SUPPLY
Motorized Variable Transformer Controlled Power Supply, P/N 18534PSInput: 460 VAC, 3 PH, 60 HzOutput: 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDC.Indoor enclosure.Output voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
product
Current Transformer
Nippen Electrical Instruments Co.
DIGITAL METERS NIPPEN electronic energy meters are panel mounting type innovative energy monitoring devices ,having state of the art electronic microcontroller circuitry for reliability and accuracy. They can be used for 1Ø / 3Ø balanced and unbalanced loads.
-
product
Current Transformer Testers
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
product
Split type AC Current Transformer
CTF-400T
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
product
Transformer Winding Resistance Tester
KRI 9310
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
product
Transformer Testing
The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.
-
product
Split Core Current Transformer
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
product
Transformer Turn Ratio Instrument
ART-3D
The ART-3D is high precision instrument designed to measure ratios, magnetization currents, phase-shifting in power transformers, distribution transformers, potential and current transformers, in conformity to IEEE C57.12.90 and CEI/IEC 60076.
-
product
Transformer Oil BDV Tester (Single Cup)
HTJY-80B / 288
Wuhan Huatian Electric Power Automation Co., Ltd.
The tester is designed to test the power strength of all kinds of insulating oil.
-
product
Separating Transformers
Is a transformer in which the primary and secondary windings are galvanically/electri- cally separated with basic insulation. Isolating transformer: A separating transformer with a protective partition between the primary and secondary windings.
-
product
Split-Core Current Transformers
CTS Series
Continental Control Systems LLC
The CTS series CTs are available with windows from 0.75 inch up to 2.0 inch. They have a removable section, so that they can be installed without interrupting the circuit. 0.333 Vac output at rated current Accuracy ±1% from 10% to 100% of rated current Phase angle <2° degrees at 50% of rated current (valid for 70 A or higher) 8 ft. twisted-pair wire, 600 Vac rated UL recognized for voltages up to 600 Vac, CE mark, RoHS
-
product
Adjustable Isolating Transformers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).
-
product
Automatic Transformer Test System
TH2840NX
Changzhou Tonghui Electronic Co., Ltd.
■ The test speed is as high as 1000 times/s (>10kHz), without relay action time ■ Test level up to 20Vrms ■ The bias voltage is built-in ±40V/±100mA/2A ■ Up to 288 test pins (only TH2840NX) ■ Industry-friendly user experience: Linux bottom layer, built-in help file
-
product
Transformer Testing Instrument
The Motwane Manufacturing Company
Transformers are a vital link in the electrical distribution system. Accurate and timely transformer maintenance can prevent breakdowns by detecting potential causes, and eliminating them before danger strikes. In addition, regular maintenance ensures multiple years of trouble-free operation. Motwane offers a wide range of transformer maintenance products, such as the transformer turn ratio tester, winding resistance tester, automatic oil BDV tester, and oil tan delta resistivity tester.
-
product
Transformer Turns Ratio Tester
CX-BY
Shenzhen Chuangxin Instruments Co., Ltd.
It is to test voltage ratio, vector, polarity, ratio error of current transformer and voltage transformer.
-
product
Precision Multirange Current Transformer
P-2000
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
product
Injection Transformer
J2101A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
Transformer Demagnetization Tester
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
product
AC Current Transformers
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers.
-
product
Phase Shifting Transformer
Supreme Instrument Laboratories
Supreme make PHASE SHIFTING TRANSFORMERS are special transformers which provide convenient means to adjust phase angle (power factor) of A.C. loading circuit while testing power factor sensitive device for the full 90 degree LAG through '0' degree to 90 degree LEAD. Based on their rating these Phase shifters are manufactured in two configuration.
-
product
Transformer Oil Breakdown Voltage Tester
HBVT
Hention Electrical Equipment Co., Ltd.
HBVT Transformer Oil Breakdown Voltage Tester , in accordance with IEC156, is designed to check insulating oil’s dielectric strength.The test set is compact and portable, therefore suitable for field work.