product
PXI/PXIe Very High Density Multiplexer, 5-Channel, 32-Pole
40-675B-002-5/32
The 40-675B-002-5/32 (PXI) and the 42-675B-002-5/32 (PXIe) are 5-channel, 32-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
product
PXIe-2527, 32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module
780587-27
32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module—The PXIe‑2527 is a high‐voltage PXI multiplexer switch module that is ideal for medium‑ to high‑density automated test applications. Featuring high-power electromechanical relays, the PXIe‑2527 is the perfect front end for the PXI DMM modules, offering simple channel expansion for a variety of measurements. The PXIe‑2527 supports multiple channel configurations including 64x1 1‑wire, 32x1 2‑wire, and 16x1 4‑wire. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
product
PXI 4 Banks of 40 Channel 1 Pole MUX
40-615-022-4/40/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 6GHz, 50Ω, SMA, Remote Mount
40-784B-003-E
The 40-784B-003-E (PXI) and 42-784B-003-E (PXIe) are triple SP6T 6GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
PXI/PXIe Microwave Multiplexer, Single SP6T, 40 GHz, 50 Ω, SMA-2.9, Remote Mount, Failsafe
42-784B-041-E
The 40-784B-041-E (PXI) and 42-784B-041-E (PXIe) are single failsafe SP6T 40 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated Common, 3GHz, 50Ω, SMB
42-876A-002
The 40-876A-002 (PXI) and 42-876A-002 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
product
PXI Very High Density Multiplexer, 10-Channel, 16-Pole
40-675A-002-10/16
The 40-675A-002-10/16 is a 10-channel, 16-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
product
PXI Dual 6 To 1 RF Multiplexer, 8GHz 50Ω SMA, Terminated
40-881A-002
The 40-881A-002 is a dual 6 to 1 50Ω RF multiplexer with 8GHz bandwidth and automatic termination of unused signal channels. It is available as a single or dual MUX in one and two PXI slots respectively.
-
product
PXI/PXIe MEMS Optical MUX, Dual 2-Channel, Single-Mode, 9/125 Fiber
40-855A-022-HI
The 40/42-855A-022-HI is a PXI/PXIe dual 2-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe RF Multiplexer, Quad 4-Channel, Terminated, 8GHz, 50Ω, SMA
40-882B-004
The 40-882B-004 (PXI) and 42-882B-004 are quad 50Ω 4 to 1 RF multiplexers with 8GHz bandwidth.The 40/42-882B range has automatic termination of unused signals and is available as a single MUX in one slot, a dual MUX in two slots, or triple and quad MUXs in three slots.
-
product
PXI High Density MUX BRIC, 4-Chan, 40-Pole
40-570-211
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
product
LXI Dual 2x2 Optical MUX LC Multi-Mode
60-851-405
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
product
PXI 12 Channel High Voltage Multiplexer
40-320-001
The 40-310/320 Range of High Voltage Switching Modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications for the 40-310/320 series modules include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.
-
product
PXI High Density Screened MUX 47-Ch 1-Pole
40-640-021-S/47/1
The multiplexer module is available as a 47-channel 2-pole, 94-channel 1-pole or 47-channel 1-pole with screened relays. Connections are made via a front panel 96-pin connector.
-
product
PXI 2A Multiplexer, 1-Bank, 128-Channel, 1-Pole
40-614C-015
This 1-bank, 128-channel, 1 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI 8-slot BRIC Power Multiplexer, 9-Channel, 16-Pole (5 Sub-cards)
40-571A-203
The 40-571A-203 is a 9-channel, 16-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
product
PXIe-2593, 500 MHz, 50 Ω PXI RF Multiplexer Switch Module
780587-93
PXIe, 500 MHz, 50 Ω PXI RF Multiplexer Switch Module—The PXIe‑2593 can be programmatically configured as unterminated multiplexers, externally terminated multiplexers, or dimensionally flexible sparse matrices.
-
product
PXI/PXIe RF Multiplexer, Single 6-Channel, Terminated, 8GHz, 50Ω, SMA
42-881B-001
The 40/42-881B has low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the module ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
product
PXI/PXIe MIL-STD-1553 Multiplexer, Dual 16-Channel, 2-Pole
40-739-002
The 40-739-002 (PXI) and 42-739-002 (PXIe) are dual 16-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
product
Single 32 To 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-767A-001
The terminated single 32 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
PXI 8-slot BRIC Multiplexer, 8-Channel, 40-Pole (4 Sub-cards)
40-570A-212
The 40-570A-212 is a 8-channel, 40-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 8-Channel, 8-Pole
42-614D-013
The 40-614D-013 (PXI) and 42-614D-013 (PXIe) 2-bank, 8-channel, 8-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI Dual SP6T Multiplexer 2.5GHz 75, 1.6/5.6
40-785B-752
The 40-785B-752 is a dual 75Ω 6-channel 2.5GHz unterminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI/PXIe RF Multiplexer, Single 4-Channel, 3GHz, 75Ω, SMB
40-832A-001
The 40-832A-001 (PXI) and 42-832A-001 are 75 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
LXI Dual 8:1 Optical MUX LC Single Mode
60-850-412
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber
40-852A-218-M50
The 40/42-852A-218-M50 is a PXI/PXIe 8-channel multiplexer with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
PXI 2A Multiplexer, 16-Bank, 4-Channel 2-Pole
40-614A-002
This 16-bank, 4-channel, 2 pole version is part of the 40-614A High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.These 2A multiplexer modules are designed for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
PXI 5 Banks of 16 Channel 1 Pole MUX
40-615-021-5/16/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 32-Channel, 4-Pole
42-614D-017
The 40-614D-017 (PXI) and 42-614D-017 (PXIe) 1-bank, 32-channel, 4-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI/PXIe Microwave Multiplexer, Single SP4T, 18GHz, 50Ω, SMA, Terminated
40-785C-421-T
The 40-785C-421-T (PXI) and 42-785C-421-T (PXIe) are single SP4T 18GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.